Panasonic Grid-EYE AMG88 Series Manual Download Page 2

Design and specifications are each subject to change without notice.  Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.

Infrared Array Sensor Grid-EYE (AMG88)

Infrared array sensor

3.3 V.DC or 5 V.DC

Selector

Thermistor

Gain

amp

ADC

Control

ROM

SDA

SCL

AD_SELECT

INT

I

2

C I/F

Sensor chip

VDD

Capacitor
10 μF

GND

GND

9

6

2

3

5

4

Item

Absolute maximum ratings

Terminal

Applied voltage

−0.3 V.DC to 6.5 V.DC

VDD

Input voltage

−0.3 V.DC to VDD +0.3 V.DC

SCL, SDA, AD_SELECT

Output sink current

−10 mA to 10 mA

INT, SDA

Static electricity (Human body model)

1 kV

All terminals

Static electricity (Machine model)

200 V

All terminals

Item

Performance

High gain

Low gain

Temperature accuracy

Typical ±2.5 °C 

±4.5 °F

Typical ±3.0 °C 

±5.4 °F

Human detection distance 

1

Max. 5 m 

16.404 ft

Viewing angle

Typical 60 °

Optical axis gap

Within Typical ±5.6 °

Current consumption

Typical 4.5 mA (normal mode)
Typical 0.2 mA (sleep mode)
Typical 0.8 mA (stand-by mode)

Setup time

Typical 50 ms (Time to enable communication after setup)
Typical 15 s (Time to stabilize output after setup)

Item

Performance

Number of pixel

64 (Vertical 8 

×

 Horizontal 8 Matrix)

External interface

I

2

C (fast mode)

Frame rate

Typical 10 frames/sec or 1 frame/sec

Operating mode 

1

Normal

Sleep

Stand-by (10 sec or 60 sec intermittence)

Output mode

Temperature output

Calculate mode

No moving average or Twice moving average

Temperature output resolution

0.25 °C

Number of sensor address

2 (I

2

C slave address)

Thermistor output temperature range

−20 °C to 80 °C –4 °F to +176 °F

Thermistor output resolution

0.0625 °C

Note: 

1  To have more than 4 °C 

7.2 °F

 of temperature difference from background

 

 

Detection object size: 700 

×

 250 mm 

27.559 

×

 9.843 inch

 (Assumable human body size)

Note: 

1  

Normal Mode : normal operation mode; Sleep Mode: detection is off (output and data reading not possible); Standby Mode: 1 frame measuring 
intermittently every 10 or 60 sec.

 INT terminal 

4

 normally has same voltage as VDD. When interrupting, same as GND (0V)

Absolute Maximum Ratings

Characteristics

Performance

Internal Circuit

Aug. 2015

00

Summary of Contents for Grid-EYE AMG88 Series

Page 1: ... on Advanced MEMS Technology High function home appliances microwaves and air conditioners Energy saving at office air conditioning lighting control Digital signage Automatic doors elevators Product name Number of pixel Operating voltage Amplification factor Part number Infrared array sensor Grid EYE 64 Vertical 8 Horizontal 8 Matrix 3 3 V DC High gain AMG8831 Low gain AMG8832 5 0 V DC High gain AMG...

Page 2: ... 4 5 mA normal mode Typical 0 2 mA sleep mode Typical 0 8 mA stand by mode Setup time Typical 50 ms Time to enable communication after setup Typical 15 s Time to stabilize output after setup Item Performance Number of pixel 64 Vertical 8 Horizontal 8 Matrix External interface I2 C fast mode Frame rate Typical 10 frames sec or 1 frame sec Operating mode 1 Normal Sleep Stand by 10 sec or 60 sec inte...

Page 3: ...31 10 0 7 10 0 028 P1 27 0 05 4 5 08 P0 050 0 002 4 0 200 8 7 0 138 0 343 P 51 Part No AMG88 is omitted Lot No 1 5 5 3 8 9 0 350 7 8 13 2 0 3 0 0 307 13 0 079 0 118 14 0 5 14 0 020 10 9 0 429 P1 27 4 P0 050 4 4 3 0 059 0 169 N 1 7 1 7 8 N 8 Lens 2 6 0 102 2 0 0 079 8 0 0 209 0 315 11 6 0 457 1 Pixel array Pixel array from 1 to 64 is shown below 1 Each pixel s viewing central angle Sensor s optical...

Page 4: ...en substances e g foreign substances or water which hardly transmit a far infrared ray adhere to the lense of the sensor Use environment 1 Temperature See the specifications 2 Humidity Between 15 and 85 R H Avoid freezing and dew condensation 3 Atmospheric pressure Between 86 and 106 kPa 4 Vibrations and shocks may damage the sensor and cause malfunction and performance deterioration If loads and ...

Page 5: ...age environment as high humidity or high temperatures generally accelerates deterioration of the electronic component The temperature range does not guarantee the durability Mounting Use the land of the printed circuit boardon which the sensor is securely fixed The recommended printed circuit board is FR4 thickness 1 6 mm 0 063 inch When mounting on the deprecated circuit board carefully check the...

Page 6: ...itions and details of the attachment position 2 Have sufficient margin values of driving performance guarantee described in the specifications and apply safety measures with double circuits if serious effects on human lives or property are predicted due to a quality failure of the product Those countermeasures are also for the product liability 3 A warranty period is one year after the delivery to...

Reviews: