61
Chapter 3
4) Select the height detection mode.
5) Set the tolerance judgment value.
Enter the upper and lower limit values for GO judgment in respect to the reference
position (zero point).
・
Upper limit value (H-thr): Enter the positive tolerance.
・
Lower limit value (L-thr): Enter the negative tolerance.
6) Press the
key to return to the detection state.
"-----" is displayed until the first measurement result is obtained.
Reference
For details of the upper/lower limit value entry method, refer to section "
3.2
Upper and Lower Limit Value Settings
" on page 48.
7) Supply an external trigger signal at the timing input terminal to hold the
detection value at the time and output of judgment. (Sample hold)
POINT
・
The upper and lower limit values having been entered before the height
detection mode is selected change during mode selection, so that the limit
values must be entered again.
・
There is another method for setting the upper and lower limits in respect
to actual upper and lower limit samples. (Upper and lower limit value entry
through teaching)
<Detection state>
<Application mode>
<BDC detection mode>
Press to select "APPLI".
<Rotation/eccentricity mode>
<Height detection mode>
End of entry
Negative slope
Press the key to return.