5
Notes
1. The maximum incident light intensity displayed depends on the selected response
time.
Response time
Incident light intensity
STD, H-SP, FAST
Max. 4,000
LONG
Max. 8,000
U-LG, HYPR
Max. 9,999
2. When the timer is used, set the timer time.
Timer range
Timer period
Display
1/10ms
Approx. 0.1 – 999.9ms
1 – 9999
3. When setting the shift amount using the digit display, the setting range differs
depending on the response time, as shown in the table below
Response time
Shift amount
STD, H-SP, FAST
Max. 4,000
LONG
Max. 8,000
U-LG, HYPR
Max. 9,999
4.
T
o clear the value, turn off the time period holding function. Turning off the power
switch also clears the value.
5. If you have selected limit teaching for the changed incident light intensity (Algo-
rithm setting =
), note that the shift direction of the threshold differs depending
on the combination of the sensing output status and the sensing output operation.
Sensing output
status
Sensing output
operation
Shift direction
ON
Light-ON
–
ON
Dark-ON
+
OFF
Light-ON
+
OFF
Dark-ON
–
Details on the menu items
Pro1 menu
Menu item
Default
setting
Description
Response time
setting
Set response time.
Timer setting
Set operation and delay of the timer.
Timer range
setting
Set the timer range and the timer time (display
example with OFF-delay timer)
Shift amount
setting
Set the shift amount for the threshold value when
you execute limit teaching (see “Limit teaching” on
Pro2 menu
Menu item
Default
setting
Description
Teaching lock
setting
Be able to prevent from wrong operation of teaching.
The lock is deactivated, teaching can be
performed.
The lock is activated, teaching is not possible.
Setting items
in the digital
display
Select what should be displayed in red on the digital
display. Choose between the incident light intensity
displayed as a percentage or the peak/bottom value.
Peak/bottom
hold function
setting
Peak/bottom values are refreshed regularly.
Peak/bottom values are held.
Setting of digital
display turning
When you set this parameter to ON, the digital dis-
play will be rotated by 180°.
ECO setting
The power consumption can be lowered.
Power consumption is normal.
If no key is pressed for 20s in RUN mode, the
digital display turns OFF.
If no key is pressed for 20s in RUN mode or
the key lock function has been activated, the
digital display and all indicators turn OFF.
Pro3 menu
Menu item
Default
setting
Description
Display
adjustment
setting
Set the incident light intensity to the target value. When
you set the display adjustment while the incident light
intensity does not have enough margin, the display
shows a blinking
.
Display adjustment OFF
Set the display to 0. This redefines the initially
displayed value as zero.
Reset setting
–
If you select the setting
, the amplifier returns to the
factory settings.
Interference
prevention
setting
The interference prevention function is disabled.
Use up to 4 different emitting frequencies. A
maximum of 4 sensor heads can be cascaded
per frequency setting.
Set this to minimize the effect of ambient
environment.
When this setting is set, mutual interference
prevention function is disabled.
The response time is as follows when
or
is
selected
Response
time
F-1: max. 0.8ms, F-2: max. 0,9ms
F-3: max. 1.0ms, F-4: max. 1.7ms
(Not affected by “
”
set
-
ting.
(
Response time setting
)
STD: max.500
μ
s, LONG: max.
4ms, U-LG: max. 8ms,HYPR:
max. 48ms
(
selectable
)
Threshold
value follow-
up cycle
The incident light intensity can be monitored for the
cycle (1 to 9,999s) specified, for example when varia-
tions in incident light intensity are expected. When the
threshold value follow-up cycle is set, the threshold
value is adjusted according to the shift based on the
incident light intensity detected. However, the threshold
value is not stored
Sensing
output
setting
Select whether the threshold value should be followed
when the output is OFF or when the output is ON.
Storage
cycle set-
ting
Select the cycle for storing threshold values in the non-
volatile memory. The valid range is 1 to 250 times
Algorithm
setting
When limit teaching is used, the threshold value
is modified by the shift amount. The direction
of the threshold shift differs depending on the
combination of the sensing output status and
the sensing output operation, see note
(Recommended when using thru-beam-type
fiber or specular reflective-type fiber)
When auto teaching is used, the threshold value
is followed up on the basis of each cycle. (Rec-
ommended when using reflective-type fiber)
Notes
The direction of the threshold shift differs depending on the combination of
the sensing output status and the sensing output operation.
Sensing output
status
Sensing output
operation
Shift direction
ON
Light-ON
–
ON
Dark-ON
+
OFF
Light-ON
+
OFF
Dark-ON
–
13
Error codes and troubleshooting
The following error codes may appear in the digital display
Error
code
Description
Remedy
The non-volatile memory is broken or
reached the end of its working life.
Please contact our office.
Error writing on the non-volatile memory
Load of the sensing output is short-cir-
cuited causing an over-current to flow.
Check that all amplifiers are
firmly attached and that there
is no gap between amplifiers.