Digital Fiber Sensor Amplifier for IO-Link

FX-550L 

Series

ME-FX550LV1EN 09/2018

Thank you for purchasing Panasonic products. Please read this Instruction 

Manual carefully and thoroughly for the correct and optimum use of this 

product. Kindly keep this manual in a convenient place for quick reference.

WARNING

 

● Never use this product as a sensing device for personnel protection.

 

● In case of using sensing devices for personnel protection, use prod-

ucts which meet laws and standards, such as OSHA, ANSI or IEC 

etc., for personnel protection applicable in each region or country.

Note

This product is not equipped with an automatic interference prevention 

function. By setting different frequencies, interference can be prevented for 

up to four units.

For the setting method, refer to <PRO3> in section 12 “PRO MODE”.”

1

Compliance with standards

This product complies with the following standards and 

regulations.

 

● For the EU: EMC Directive 2014/30/EC

 

Contact for CE:

 

Panasonic Marketing Europe GmbH

 

Panasonic Testing Center

 

Winsbergring 15, 22525 Hamburg, Germany

 

2

Part description

1

2

3

4

5

6

7

8

9

1

Operation indicator for sensing output (orange)

2

Digital display (green/red)

3

UP key (+)

Functions:

 

● Teach

 

● Fine adjustment of the threshold value

 

● Select settings

4

DOWN key (–)

5

MODE key

Functions:

 

● Select modes

 

● Cancel

6

SET key

Functions:

 

● Teach

 

● Save selected settings

7

Mode indicator PRO mode (yellow)

Lights in PRO mode
Flashes in normal status during IO-

Link communication
OFF in normal status without IO-

Link communication

8

Mode indicator CUST (custom) 

mode (yellow)

Lights when setting “Light sensitivity 

setting mode”

9

Mode indicator L /D (Light-ON/Dark-

ON) mode (yellow)

Lights when setting “Sensing output 

operation mode”

3

Mounting

Installation to a DIN rail

1.  Attach the railing on the rear of the ampli-

fier to the DIN rail.

2.  Push the amplifier in the direction of the 

arrow as illustrated so that it attaches 

securely.

1. 

2. 

Removal from a DIN rail

1.  Push the amplifier forward.
2.  Lift the front part of the amplifier up.

1. 

2. 

Connecting the fiber cable

 

● Mount the fiber cables when the power is off.

 

● The attachments to the fiber cables need to be fitted BEFORE you 

insert the fibers into the amplifier. For details, refer to the instruction 

manual enclosed with the fibers.

 

● Insert the fiber cables slowly into the inlets until they stops. Excessive 

force may damage the product

1.  Snap the fiber lock lever 

1

 down as 

far as it will go.

2.  Insert the fiber cables slowly into the 

inlets until they stop (see note).

3.  Return the fiber lock lever to the 

original position.

2. 

1.  3. 

Note:
With the coaxial reflective type fiber, insert the single core fiber cable into 

the inlet for the emitter 

(inlet on the amplifier is labeled “P”) and the 

multi-core fiber cable into the inlet for the receiver 

3

. If they are inserted 

the wrong way round, the sensing performance will deteriorate.

4

I/O circuit diagrams

As a general-purpose sensor

Connected to a IO-Link master

This produc

t

IO-Link maste

r

(Brown / 1) +V 

+V 

(Black / 4) C/Q

C/Q

(

White / 2) DO

DI

(Blue / 3) 0V

0V

(

Brown / 1) +V 

(

Black / 4) C/Q Note

(White / 2) DO

(

Blue / 3) 0V

Load

Load

+
-

24V DC

±10%

Terminal arrangement of M12 connector

Note:

When 

the product is used as a general-purpose sensor, the 

IO-Link communication output (C/Q) provides the same output 

operation as the control output (DO).

1

4

2

3

Terminal No.

Terminal name

1

+V

2

Control output (DO)

3

0V

4

IO-Link communication (C/Q)

Summary of Contents for FX-550L Series

Page 1: ...itivity setting mode 9 Mode indicator L D Light ON Dark ON mode yellow Lights when setting Sensing output operation mode 3 Mounting Installation to a DIN rail 1 Attach the railing on the rear of the ampli fier to the DIN rail 2 Push the amplifier in the direction of the arrow as illustrated so that it attaches securely 1 2 Removal from a DIN rail 1 Push the amplifier forward 2 Lift the front part ...

Page 2: ...161 Preventive maintenance threshold value detection lag time setting Index162 Operating time Index163 Number of data save opera tions Index164 Notification Flag Setting Index168 Notification Event Code Index169 Note For the IO Link communication setting refer to the attached sheet Index list 6 Operation procedure If you change settings press the SET key before you turn the power OFF Otherwise you...

Page 3: ...ng the shift amount refer to PRO1 in section 12 PRO MODE 2 At the time of limit teaching UP key System command Index2 0x4B DOWN key System command Index2 0x4C Auto teaching When the sensing object is moving use this teaching method 1 Press and hold the SET key for a long time 2 Run the sensing object on the production line and hold down the SET key system command Index2 0x47 3 The display shows in...

Page 4: ... key select Press the SET key MODE key select cancel Press the UP or DOWN key Device moves automati cally to the next item MODE indicator PRO yellow Procedure SET SET SET SET PRO1 250μs 2ms 4ms 24ms SET SET SET SET SET SET PRO2 SET PRO3 SET SET SET SET SET SET SET PRO1 OFF SET SET SET OFF ON OFF Display adjustment setting Turning OFF Turning ON Eco setting Full Setting of digital display turning I...

Page 5: ...ou set the display adjustment while the incident light intensity does not have enough margin the display shows a blinking Display adjustment OFF Set the display to 0 This redefines the initially displayed value as zero Reset setting If you select the setting the amplifier returns to the factory settings Interference prevention setting The interference prevention function is disabled Use up to 4 di...

Page 6: ...y voltage 12 to 24V DC 10 15 ripple P P10 max Power con sumption Normal operation 960mW max current consumption 40mA max at 24V supply voltage Eco mode 720mW max current consumption 30mA max at 24V supply voltage IO Link commu nication C Q 1 IO Link specification Ver1 1 Baud rate COM3 230 4kbit s Process data length PD 4byte Control output DO 2 PNP open collector transistor Maximum source current ...