background image

PART DESCRIPTION

6

MODE key

Jog switch

Digital display (Red)

MODE indicator /
PRO (Yellow)

MODE indicator / L/D ON (Yellow)

Output 1 operation indicator
(Orange)

MODE indicator / RUN (Green)

MODE indicator / ADJ (Yellow)

MODE indicator / TEACH (Yellow)

MODE indicator / TIMER (Yellow)

Output 2 operation
indicator (Orange)

OPERATION PROCEDURE

7

٨

When the power supply is switched on, communication self-check is car-
ried out and normal condition is displayed [MODE indicator / RUN 
(green)] lights up and the digital display shows the incident light intensity.

TEACHING MODE

8

In case of 2-level teaching

ԙ

Press Jog switch in the object present condition. If the 
teaching is accepted, the read incident light intensity blinks in 
the digital display. (Note 1)

Ԛ

Press Jog switch in the object absent condition. (Note 1)

Press

Press

Press

Ԙ

Press MODE key to light up MODE indicator / TEACH (yellow).
Set to either Output 1 '         ' or Output 2 '         '.
Turn Jog switch: Select 
Press Jog switch: Confirmed

ԛ

The threshold value is set at the mid-value between 

ԙ

 and 

Ԛ

.

In case stable sensing is possible: '

䇭䇭䇭䇭

' is displayed.

In case stable sensing is not possible: '

䇭䇭䇭䇭

' is displayed.

Note: In case of using the fibers, if Jog switch is pressed in the object absent condition at 

ԙ

 and 

Ԛ

,

the sensitivity is set to the maximum.

Press

Press

Ԙ

Press MODE key to light up MODE indicator / TEACH (yellow).
Set to either Output 1 '         ' or Output 2 '         '.
Turn Jog switch: Select 
Press Jog switch: Confirmed

ԛ

In case stable sensing is possible: '

䇭 䇭 䇭 䇭

' is displayed.

In case stable sensing is not possible: '

䇭 䇭 䇭 䇭

' is displayed.

ԙ

Press Jog switch continuously for 0.5 sec. or more with the 
object moving on the assembly line.

Ԛ

'        ' is displayed on the digital display. Release the jog 
switch when the object has passed.

In case of full-auto teaching

Press

Press

Ԙ

Press MODE key to light up MODE indicator / TEACH (yellow).
Set to Output 1 '          '.
Turn Jog switch: Select 
Press Jog switch: Confirmed

ԛ

In case stable sensing is possible: '

䇭 䇭 䇭 䇭

' is displayed.

In case stable sensing is not possible: '

䇭 䇭 䇭 䇭

' is displayed.

٨

This is the method of setting the threshold range by 1-level teaching. The shift
value can be set as desired.

In case of window comparator mode / 1-level teaching

1_SL

P-1

2_SL

Set as

desired

Set as

desired

ԙ

The current teaching method is displayed for 0.5 sec.

Ԛ

Press Jog switch in the object present condition. If the 
teaching is accepted, the read incident light intensity blinks in 
the digital display.

Ԝ

A value deducted the shift value (100) from the incident light 
intensity becomes the threshold value (1_SL), which is 
displayed. (Note 1) (Note 2)

ԝ

A value added the shift value (100) to the incident light 
intensity becomes the threshold value (2_SL), which is 
displayed. (Note 1) (Note 2)

The shift value 100 digits is the initial value. The shift value can be changed in PRO mode.
Furthermore, 'digit' or 'percent' can be selected. For the setting method refer to '

PRO

MODE

PRO6 mode setting

'.

In case the set value exceeds the max. (min.) sensitivity, the set value is fixed at max. 
(min.) sensitivity.

Notes: 1)

2)

13

In case of teaching in the window comparator mode, set the detailed settings in 
PRO6 beforehand. For the settings, refer to '

PRO MODE

PRO6 mode setting

'.

13

In case of limit teaching

Press

Press

Ԙ

Press MODE key to light up MODE indicator / TEACH (yellow).
Set to either Output 1 '         ' or Output 2 '         '.
Turn Jog switch: Select 
Press Jog switch: Confirmed

ԙ

Press Jog switch in the object absent condition. If the 
teaching is accepted, the read incident light intensity blinks in 
the digital display.

Ԛ

Turn Jog switch to the '+' side or the '-' side.
If Jog switch is turned to '+' side, the threshold value level is shifted
to a value approx. 15% higher (lower sensitivity) than that set at 

Ԙ

.

If Jog switch is turned to '-' side, the threshold value level is shifted 
to a value approx. 15% lower (higher sensitivity) than that set at 

Ԙ

ԛ

In case stable sensing is possible: '

䇭 䇭 䇭 䇭

' is displayed.

In case stable sensing is not possible: '

䇭 䇭 䇭 䇭

' is displayed.

The approx. 15% amount of shift is the initial value. The amount of shift can be changed in the 
PRO mode from approx. 0 to 80% (5% step). For the setting method refer to '

PRO MODE

PRO1 mode setting

'.

Note:

13

The 0-ADJ setting function in this product was removed from production starting May, 2005.

*1:
*2:
*3:
*4:

*5:

When Jog switch is pressed, the setting is confirmed.
When MODE key is pressed for 2 sec., or more, the sensor returns to the 'RUN' mode.
Cancellation is possible by pressing MODE key during setting.
When Jog switch is turned in the 'RUN' mode, the current threshold value is displayed.
And then, the current incident light intensity display appears again automatically.
If the jog switch and MODE key are pressed for more than 2 sec. at the same time in 'RUN' 
mode condition, the key operations are locked, and only the threshold value confirmation
function or the adjust function (valid only when the adjust lock function is canceled) is valid. 
To cancel the lock function, press both the keys for more than 2 sec. once again.

MODE key

Press

Press

Turn

'+' side

'-' side

Jog switch

٨

PRO mode

The items that can be set in output 1 and output 2 respectively are only the following.
The items other than those are common.

Ԙ

Threshold value

ԙ

Output operation

Ԛ

Timer operation and Timer priod

ԛ

Detection mode

٨

NAVI mode

This indicates normal sensing operation.

Run

RUN

Refer to '

TEACHING MODE

'.

8

Sets the threshold value by, '2-level teaching' or 
'limit teaching', 'full-auto teaching', 'Max. sensitivity 
teaching', 'Window comparator

1-level / 2-level / 

3-level teaching'.

Teaching

TEACH

Refer to '

THRESHOLD VALUE FINE 

ADJUSTMENT MODE

'.

9

Allows fine adjustment of the threshold value.

Adjust

ADJ

Refer to '

OUTPUT OPERATION 

SETTING MODE

'.

11

Sets output operation either Light-ON, or Dark-ON.

L-ON/D-ON

L/D ON

Refer to '

TIMER OPERATION

SETTING MODE

'.

12

Configures operation of the timer.

Timer

TIMER

Refer to '

PRO MODE

'.

13

Allows various detailed settings to be configured, such 
as optical communications, save/load and other settings.

Pro

PRO

Press

٨

To PRO mode

Press

Press

Press

Press

Press

Press

Refer to '

PRO

MODE PRO1 
mode setting

'.

13

Turn

Response time change function '

'

Timer setting function '

'

Hysteresis function '

'



Shift function '

'

Emitting power selection function '

'


PRO1

Refer to '

PRO

MODE PRO2 
mode setting

'.

13

PRO2

Turn

Refer to '

PRO

MODE PRO3 
mode setting

'.

13

Refer to '

PRO

MODE PRO5 
mode setting

'.

13

Refer to '

PRO

MODE PRO4 
mode setting

'.

13

Setting condition copy 
function '

'

Remote data bank load 
setting function '

'

Remote data bank save 
setting function '

'

Communication lock function '

'

Back-up function '

'


PRO4

Turn

Turn

Turn

Turn

PRO3

Data bank load setting function '

'

Data bank save setting function '

'


Refer to '

PRO

MODE PRO6 
mode setting

'.

13

PRO5

Code setting function '

'

Adjust lock setting function '

'


Setting reset function '

'

Interference prevention function
'

'


PRO6

Output setting function '

', '

'

ECO mode setting function '

'

Digital display setting function '

'

Digital display inversion function '

'


Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Summary of Contents for FX-305

Page 1: ...r circuit ٨ PNP output type Notes 1 2 The quick connection sub cable does not have V brown and 0V blue The power is supplied from the connector of the main cable 25mA max if five or more amplifiers are connected in cascade Symbols D1 D2 Reverse supply polarity protection diode ZD1 ZD2 ZD3 ZD4 Surge absorption zener diode Tr1 Tr2 NPN output transistor Tr3 Tr4 PNP output transistor Terminal arrangem...

Page 2: ...switch in the object absent condition If the teaching is accepted the read incident light intensity blinks in the digital display Ԛ Turn Jog switch to the side or the side If Jog switch is turned to side the threshold value level is shifted to a value approx 15 higher lower sensitivity than that set at Ԙ If Jog switch is turned to side the threshold value level is shifted to a value approx 15 lowe...

Page 3: ...E SHOT timer Note 2 Press Press Press Press Turn Turn Turn The range of available timer delays is 0 5ms 1 to 9999ms 1ms increments Turn Press Turn The range of available timer delays is 0 5ms 1 to 500ms 1ms increments Turn Notes 2 For OFF delay ON delay or ON delay ONE SHOT timer follow the procedure giv en below for setting Press Press Press Press Without timer Without timer Notes 1 For the incid...

Page 4: ...d is displayed The factory setting is When the code setting function is used refer to the Code setting table given below However the code setting is only for the output 1 PRO6 mode setting Normal mode Window comparator mode Press Press Press Press Press Press Press Press Press Rising differential mode Trailing differential mode Turn Turn Turn Turn Turn Press Press Press Press Turn Press Normal mod...

Reviews: