In case of full-auto teaching
٨
Full-auto teaching is used when it is desired to set the threshold value without
stopping the assembly line, with the object in the moving condition.
If the teaching is accepted, the read incident light intensity blinks in the digi-
tal display and the threshold value is set at the mid-value between the inci-
dent light intensities in the object present and the object absent conditions.
After this, the judgment on the stability of sensing is displayed.
In case stable sensing is possible: '
㵘㵘㵘㵘
' is displayed.
In case stable sensing is not possible: '
㵘㵘㵘㵘
' is displayed.
'
' is displayed on the digital display. Release the jog switch when the
object has passed.
ԛ
Ԛ
ԙ
Ԙ
Press Jog switch continuously for 0.5 sec. or more with the
object moving on the assembly line. (The incident light intensi-
ty is displayed during sampling.)
Step
Set the fiber within the sensing range.
Press MODE key to light up MODE indicator /
TEACH (yellow).
Display
Description
ԝ
Ԝ
The incident light intensity appears in the digital display and the setting is complete.
The threshold value is displayed.
Press
Press
PRO MODE
13
For details of the settings and the setting procedure of the PRO mode, refer to '
Panasonic Elec-
tric Works SUNX website
(
http://panasonic-electric-works.net/sunx
)' or contact our office.
٨
PRO settings can be done when MODE indicator / PRO
(yellow) lights up.
THRESHOLD VALUE FINE ADJUSTMENT MODE
10
When Jog switch is turned to the '-' side, the threshold value decreases (sensitivity
increases).
When Jog switch is pressed, the threshold value is confirmed.
Confirmed
Press
Turn to '+' side.
Turn to '+' side.
Confirmed
Press
Turn to '-' side.
Turn to '-' side.
٨
Fine adjustment of the threshold value can be done
when MODE indicator / ADJ (yellow) lights up.
When Jog switch is turned to the '+' side, the threshold
value increases (sensitivity decreases).
When Jog switch is pressed, the threshold value is confirmed.
OUTPUT OPERATION SETTING MODE
11
Confirmed
Press
Turn
٨
The output operation setting can be done when MODE
indicator / L/D (yellow) lights up.
The output operation is changed when Jog switch is
turned to the '+' side or the '-' side.
When Jog switch is pressed, the threshold value is confirmed.
TIMER OPERATION SETTING MODE
12
٨
٨
٨
The setting for whether the timer is used or not can be
done when MODE indicator / TIMER (yellow) lights up.
10ms OFF-delay (initial value) timer is automatically set
when the timer is set to be used.
Refer to '
PRO MODE / PRO1 mode setting
' for the setting method of the OFF-
delay timer, ON-delay timer and ONE-SHOT timer intervals.
13
Press: Confirmed
Turn
Turn
Turn
Turn
(Without timer)
ONE-SHOT
timer
OFF-delay
timer
ON-delay
timer
The timer interval set in the PRO mode is displayed.
The factory setting is without timer '
'.
Notes: 1)
2)
PRO1 mode setting
Turn
Turn
Turn
Response time: 150
Ǵ
s or less
High speed
Response time: 35
Ǵ
s or less
Ultra high speed
Reduced intensity (Note) Response time: 250
Ǵ
s or less
Response time: 250
Ǵ
s or less
Standard
Response time: 2ms or less
Long-range
Note: The S-D mode is suitable for delicate sensing, such as when
the received lights is saturated due to too short a sensing dis-
tance or when detecting translucent objects, etc.
The amount of shift can be changed approx. 0 to
80% (5% step).
Press
Press
Press
Turn
Turn
Press
Turn
Emission halt
Press
Turn
Press
Turn
Turn
Turn
Turn
Turn
Emitting power Hi
Emitting power Lo
Hysteresis: Standard
Hysteresis: Large
Hysteresis: Small
Margin width:
r
10%
Margin width:
r
15%
Margin width:
r
5%
OFF-delay timer
Without timer
ONE-SHOT timer
ON-delay timer
Amount of shift: 15% approx.
The range of available timer delays is
0.5ms, 1 to 9999ms (1ms increments).
Turn
Note: Only in the response time
H-SP mode, ON condition, the emit-
ting power is 2 level.
Press
Press
Response
time change
function
Emitting
power selec-
tion function
Timer set-
ting function
Hysteresis
function
Stability
function
Shift
function
Note: Set the threshold value at least a bit higher than the minimum threshold value. (The minimum
threshold value is where the value cannot be lowered any further even if the jog switch is