background image

INSTRUCTION MANUAL

Digital Fiber Sensor  

FX-100-Z 

series

MJE-FX100ZC No.0035-67V

Thank you very much for purchasing Panasonic products. Read this Instruction Manual 

carefully and thoroughly for the correct and optimum use of this product. Kindly keep 

this manual in a convenient place for quick reference.

WARNING

 

● Never use this product as a sensing device for personnel protection.

 

● In case of using sensing devices for personnel protection, use products which

meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protec-

tion applicable in each region or country.

1

PART DESCRIPTION

Digital display (Green)

(Threshold value)

Digital display (Red)

(Incident light intensity)

MODE key

•  Selection of setting items

•  Confirmation of set contents

ON key / Set value UP key

•  Selection of setting contents

•  Settings in teaching mode

OFF key / Set value DOWN key

•  Selection of setting contents

•  Settings in teaching mode

Operation indicator

(Orange)

2

MOUNTING

<When using a DIN rail>

How to mount the amplifier

1.

Fit the rear part of the mounting section of the amplifier

on DIN rail.

2.

Press down the rear part of the mounting section of the 

unit on the

 

DIN rail and fit the front part of the mounting

section to the DIN rail.

35mm width DIN rail

1

2

How to remove the amplifier

1.

Push the amplifier forward.

2.

  Lift up the front part of the amplifier to remove it.

Note:  Take care that if the front part is lifted without pushing the amplifier forward, 

the hook on the rear portion of the mounting section is likely to break.

1

2

<When using screws with washers>

 

● Use M3 screws with washers for mounting. The tighten-

ing torque should be 0.5N·m or less.

M3 screw with 

washer

How to connect the fiber cable

Be sure to fit the attachment to the fibers first before inserting the fibers to the ampli-

fier. For details, refer to the Instruction Manual enclosed with the fibers.

1.

In cover open condition, snap the fiber lock lever down, 

till it stops completely.

2.

Insert the fiber cables slowly into the inlets until they

stop. (Note 1) 

3.

Return the fiber lock lever to the original position, till it 

stops.

Fiber

Fiber lock lever

1

3

2

Notes:  1)  In case the fiber cables are not inserted to a position where they stop, the sensing range reduces. Since a 

flexible fiber is easily bent, take care when it is inserted.

2)  With the coaxial reflective type fiber, such as, 

FD-42G

 or 

FD-61G

, insert the single-core fiber cable into the

beam-emitting inlet “

P

” and the multi-core fiber cable into the beam-receiving inlet “

D

.” If they are inserted in 

reverse, the sensing performance will deteriorate.

3

WIRING

 

● Make sure to use the cable with connector 

CN-24A-C

□ (optional) when connecting

to this product.

 

● Tighten the fixing ring of the cable with connector completely by hand when mount-

ing. (The tightening torque: 0.3 to 0.4N·m)

 

● Make sure to hold the side surface of this product when tightening or loosening the

fixing ring of the cable with connector.

 

● If the fixing ring is tightened by a tool such as pliers, it may cause connector damage.

 

● If the tightening torque is not enough, the fixing ring may loosen due to vibration, etc.

Connection method

 

● Insert the cable with connector 

CN-24A-C

□ (optional) 

into this product’s connector area as shown in the right

figure.

Cable with

connector 

CN-24A-C

Disconnection method

 

● Loosen the fixing ring, and, holding the fixing ring, pull

to separate the connector.

Note:  Before disconnecting, make sure to check that the fixing ring is completely 

loosened. If the cable is pulled by excessive force (15N or more) when the 

fixing ring is tightened, the cable may break.

Fixing ring

<Connector pin arrangement>

1

2

3

4

Connector pin No.

Terminal name

1

+V

2

External input

3

0V

4

Output

4

I/O CIRCUIT DIAGRAMS

NPN output type

+

12 to 24V DC

±10%

-

Main circuit

(Black) Output

(White) External input

(Blue) 0V

Load

8V

Connector pin No.

(Brown) +V

Color code of cable with connector

*1

PNP output type

Load

*2

+

12 to 24V DC

±10%

-

(Black) Output

(White) External input

(Blue) 0V

Connector pin No.

(Brown) +V

Color code of cable with connector

Main circuit

*1

*2

Non-voltage contact or NPN open-collector transistor

or

High (+8V to +V DC or Open): Invalid

Low [(0 to +2V DC (Source current 0.5mA or less)] : Valid

Non-voltage contact or PNP open-collector transistor

or

High [+4V to +V DC (Sink current 0.5 to 3mA or less)]: Valid

Low (0 to +0.6V DC or Open): Invalid

5

RUN MODE

<Digital display>

● When turning ON the power, the product name is indicated on the green digital dis-

play, while the emission frequency is indicated on the red digital display. Then switch-

es into RUN mode [digital display (green: threshold value, red: incident light intensity)].

AUTO

<When turning ON the power>

Emission 

frequency

<RUN mode>

Product 

name

Threshold

value

Incident light

intensity 

 

● When selecting emission halt in the external input setting mode and receiving the 

signal externally, “

” is indicated on the red digital display.

 

● When selecting ECO in the external input setting mode, key operation on the main 

body is invalid during external input.

 

● When selecting 2-point teaching in the external input setting mode, “

” is indi-

cated on the green digital display after inputting the first point.

 

● When ECO setting mode is ON, the digital display turns off in approx. 20 sec. In 

case of lighting up the digital display again, press any key for 2 sec. or more.

 

● For the settings of external input and ECO, refer to “

PRO MODE

.”

Threshold value fine adjustment function

 

● Fine adjustment of threshold value can be done when in RUN mode.

 

● Press the set value UP key or set value DOWN key to change threshold value.

(Hold down the key to make the value change faster.)

 

● The threshold value is stored after 3 sec.

Threshold

value

Incident light

intensity 

When in RUN mode

Keylock function

● The keylock function prevents key operations so that the conditions set in each setting 

mode are not inadvertently changed.

● In the keylock condition, “

” is displayed when pressing any key.

<Keylock set>

<When in RUN mode>

Press for 2 sec.

AUTO

<Keylock released>

Press for 2 sec. or more

<When in RUN mode>

AUTO

AUTO

6

SETTING MODE

 

● Setting mode appears after 

pressing MODE key for 2 sec. in RUN mode.

 

● RUN mode appears when MODE key is pressed for 2 sec. while setting and the

changed contents have been set.

 

● Make sure to return to RUN mode before turning OFF the power. If the power is

turned OFF while setting, the changed contents have not been set.

<Setting mode>

Press for 2 sec.

Press for 2 sec.

<Teaching mode>

<Output operation setting mode>

For details, refer to “

TEACHING MODE

.”

AUTO

[email protected]

www.digiparts.ch

Ihr Schweizer Industriepartner

Summary of Contents for FX-102P

Page 1: ...optional into this product s connector area as shown in the right figure Cable with connector CN 24A C Disconnection method Loosen the fixing ring and holding the fixing ring pull to separate the connector Note Before disconnecting make sure to check that the fixing ring is completely loosened If the cable is pulled by excessive force 15N or more when the fixing ring is tightened the cable may bre...

Page 2: ...ndition Thru beam type Light received condition Reflective type Mark Light interrupted condition Base The first incident light intensity is set and indicated on the green digital display Cancellation of the setting for the first incident light intensity is possible when MODE key is pressed The present incident light intensity blinks in red at the digital display Press OFF key in object present con...

Page 3: ...de 9 EXTERNAL INPUT SETTING When selecting emission halt in the external input setting mode and receiving the signal externally is indicated on the red digital display When selecting ECO in the external input setting mode key operation on the main body is invalid during external input When selecting 2 point teaching in the external input setting mode is indi cated on the green digital display afte...

Page 4: ...ss 2 power supply unit Contact for CE Until June 30 2013 Panasonic Electric Works Europe AG Rudolf Diesel Ring 2 D 83607 Holzkirchen Germany From July 1 2013 Panasonic Marketing Europe GmbH Panasonic Testing Center Winsbergring 15 22525 Hamburg Germany 1 Turn on the master side amplifier and the slave side amplifier at the same time Note 2 is shown on the green digital display of the master side a...

Reviews: