FV-10VEC2

FV-10VEC2H

FV-10VE2

FV-10VE2H

CONTENTS
GENERAL SAFETY INFORMATION
DESCRIPTION

Model No.

2~3

READ AND SAVE THESE INSTRUCTIONS

Thank you for purchasing this Panasonic product.

Please read these instructions carefully before attempting to install, operate or service the 

Panasonic product. Please carefully read the “GENERAL SAFETY INFORMATION” (P.2~3) of 

this manual before use. Failure to comply with instructions could result in personal injury or 

property damage. Please explain to users how to operate and maintain the product after 

installation, and this booklet should be presented to users.

Please retain this booklet for future reference.

4

Installation and Operating Instructions

Energy Recovery Ventilator

WIRING DIAGRAM

WIRING METHOD

DUCT INSTALLATION

INSTALLATION

(WALL MOUNT)

INSTALLATION

ⅠⅠ

 

 

(CHAIN MOUNT)

START-UP PROCEDURE
OPERATION

13~15

TROUBLESHOOTING

18

MAINTENANCE

16~17

SPECIFICATIONS
PRODUCT SERVICE

BACK COVER

19

7~8

5~6

8~11

12
13

4~5

1 0 V C 2 M 4 5 0 A

Summary of Contents for FV-10VEC2

Page 1: ...ailure to comply with instructions could result in personal injury or property damage Please explain to users how to operate and maintain the product after installation and this booklet should be pres...

Page 2: ...f fire or electric shock do not use this unit with any solid state control device This symbol is used to alert users to a specific operating procedure that must be followed in order to operate the uni...

Page 3: ...ear the fan motor fixture or wiring cover For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors Sufficient air is needed for proper combustion and exhausti...

Page 4: ...into the incoming cold air and pre cooling and reducing the humidity of the incoming hot air This helps maintain a fresh environment even when the heating or cooling system is not operating Heating Co...

Page 5: ...l Neutral Earth ground Live Live WHITE BLACK GREEN Wire Nuts FV 10VEC2H FV 10VE2H Only FV 10VEC2H R JUNCTION BOX GREEN WHITE BLACK GROUND NEUTRAL LIVE R G G Installation work and electrical wiring mus...

Page 6: ...the HVAC AHU please open knock out holes for wall switch and boost switch connection only 4 Insert wires into the corresponding terminals deeply through the ribs Make sure the screw of terminal secure...

Page 7: ...e on wall bracket according to the distance between studs Unit inches mm A B 24 609 6 16 406 4 19 482 6 17 1 2 444 5 14 1 2 368 3 22 1 2 571 5 A B Stud 4 long screws ST4 2X30 Stud Wall bracket Floor E...

Page 8: ...t straight run on all duct attachments points before elbow is more than 2 ft 610 mm 2 Unit is normally balanced on high speed with the furnace blower on 3 A minimum separation of 40 inches 1 m is reco...

Page 9: ...allation Note 1 The ERV unit must be balanced 2 It is mandatory that HVAC AHU signal cord be connected 3 Check local codes and authority having jurisdiction for acceptance Note 1 Must Have 2 3 ft stra...

Page 10: ...and living areas Method Fully dedicated ducted installation Note 1 The ERV unit must be balanced 2 Check local codes and authority having jurisdiction for acceptance Note 1 Must Have 2 3 ft straight...

Page 11: ...o the OA and EA adapter 1 2 Attach duct rigid galvanized duct etc to the SA and RA adapter Please refer to the local codes for detail The intake side duct must be connected to the outside and at least...

Page 12: ...ains are not supplied Please purchase chains which must be subjected to the weight of 66 lbs 30 kg or above 2 Make sure ERV is horizontal after installation Note Chain Hanger Hanger Install Hanger Ins...

Page 13: ...on off 1 2 3 4 SA knob Set the supply air volume with this knob The factory default is 100 CFM The unit will consume some electricity unless you turn off the main switch OPERATION Note The SA air vol...

Page 14: ...the customer to set as ASHRAE 50 min h SA 90 CFM EA 90 CFM ON ON OFF when boost switch is ON ERV enforces the instructions ASHRAE 60 min h SA 100 CFM EA 100 CFM when boost switch is OFF ERV restores...

Page 15: ...C 104 F 40 C FV 10VE2 FV 10VE2H OA damper open Heat exchange mode Outside air OA Exhaust air EA Supply air SA Return air RA Supply air SA Return air RA Example of FV 10VEC2 and FV 10VEC2H Outdoor tem...

Page 16: ...wer by switching off main switch first then unplug before working on unit when it is in default mode CAUTION Routine maintenance must be performed every 2 or 3 months clogged filters may cause condens...

Page 17: ...pi3 min pi3 min It is suggested to replace the OA filter every 6 months Please fill in beginning time on new OA filter before replacing Please replace OA filter by Panasonic Model FV FL0810VE1 or FV F...

Page 18: ...iring connect SA motor error please disconnect the power and contact the dealer for repair Off Blink 2 s Blink 2 s EA motor error please disconnect the power and contact the dealer for repair OA dampe...

Page 19: ...6 SPECIFICATIONS Weight Ib For FV 10VEC2 and FV 10VEC2H To ensure quiet operation of the ENERGY STAR certified H ERV each product model must be installed using sound attenuation techniques appropriat...

Page 20: ...c com Panasonic Corporation 2023 Issue date 05 2023 Warning Concerning Removal of Covers The unit should be serviced by qualified technicians only Your product is designed and manufactured to ensure a...

Reviews: