Panasonic FV-08-11VF5 Installation Instructions Manual Download Page 2

2

For  Your  Safety

To  reduce  the  risk  of  injury,  loss  of  life,  electric  shock,  fire,  malfunction,  and  damage  to  equipment 
or  property,  always  observe  the  following  safety  precautions.

Explanation  of  symbol  word  panels

The  following  symbol  word  panels  are  used  to  classify  and  describe  the  level  of  hazard,  injury,  and 
property  damage  caused  when  the  denotation  is  disregarded  and  improper  use  is  performed.

CAUTION

Denotes  a  potential  hazard  that  could  result  in  serious  injury 
or  death.

Denotes  a  hazard  that  could  result  in  minor  injury.

WARNING

The  following  symbols  are  used  to  classify  and  describe  the  type  of  instructions  to  be  observed.

This  symbol  is  used  to  alert  users  to  a  specific  operating  procedure  that  must  not  be 
performed.

This  symbol  is  used  to  alert  users  to  a  specific  operating  procedure  that  must  be  followed 
in  order  to  operate  the  unit  safely.

This  symbol  is  used  to  alert  users  not  to  disassemble  the  equipment.

This  symbol  is  used  to  alert  users  to  make  sure  of  grounding  when  using  the  equipment 
with  the  grounding  terminal.

GENERAL SAFETY INFORMATION

Use  this  unit  only  in  the  manner  intended  by  the  manufacturer.  If  you  have  any  questions, 
contact  the  manufacturer. 

Before servicing or cleaning unit, switch power off at service panel and lock the service 
disconnecting means to prevent power from being switched on accidentally. When the 
service disconnecting means cannot be locked, securely fasten a prominent warning device, 
such as a tag, to the service panel.

Installation  work  and  electrical  wiring  must  be  done  by  qualified  person(s)  in  accordance  with
all  applicable  codes  and  standards,  including  fire-rated  construction.

Ducted  fans  must  always  be  vented  to  the  outdoors.

If  this  unit  is  to  be  installed  over  a  tub  or  shower,  it  must  be  marked  as  appropriate  for  the 
application  and  be  connected  to  a  GFCI(Ground  Fault  Circuit  Interrupter)  -  protected  branch 
circuit. 

To  reduce  the  risk  of  fire,  electric  shock  or  injury  to  persons,  observe  the  following  :

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE) and the local code authorities.

When  cutting  or  drilling  into  wall  or  ceiling,  do  not  damage  electrical  wiring  and  other 
hidden  utilities.

WARNING

Summary of Contents for FV-08-11VF5

Page 1: ...ease explain to users how to operate and maintain the product after installation and this booklet should be presented to users Please retain this booklet for future reference FV 08 11VFM5 FV 08 11VF5 Model No FV 08 11VFM5 FV 08 11VF5 GENERAL SAFETY INFORMATION DESCRIPTION UNPACKING SUPPLIED ACCESSORIES DIMENSIONS WIRING DIAGRAM FEATURE INSTALLATION NEW CONSTRUCTION INSTALLATION RETROFIT MAINTENANC...

Page 2: ...uestions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person...

Page 3: ...t kink the supply wiring Protect the supply wiring from sharp edges oil grease hot surfaces chemicals or other objects Always disconnect the power source before working on or near the fan motor or junction box Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupation Safety and Health Act OSHA Do not install these ventilating fans where interior ro...

Page 4: ... sirocco fan developed to reduce the noise level These products have two speeds 80 is low airflow and 110 is high airflow FV 08 11VFM5 is equipped with a motion sensor that shifts the fan to vent automatically when motion is detected It stops the flow automatically after 20 minutes when motion is no longer detected 1 Part name Appearance Quantity Self drilling screw 4 Warranty sheet 1 2 Installati...

Page 5: ...itch Sensor unit Blade 11 TM Flex Z Fast bracket Pick A Flow switch Blade Adaptor connector TM Flex Z Fast bracket 12 1 8 307 12 1 8 307 FV 08 11VF5 5 5 8 143 13 330 13 330 11 10 1 4 260 6 150 3 3 8 85 10 1 4 260 6 150 3 3 8 85 10 5 5 8 143 2 15 16 74 2 15 16 74 2 7 8 72 1 26 9 8 2 7 8 72 1 26 ...

Page 6: ...80 CFM Air volume options Factory setting 80 CFM 110 CFM 80 110 CFM 80 110 CFM Pick A Flow Feature These products come with Pick A Flow speed option The Pick A Flow switch on the surface of the products allows the option to choose 80 110 CFM FEATURE Pick A Flow switch ...

Page 7: ...nstall the TM Flex Z Fast bracket to joists by using the 2 pre installed tapping screws Fig 2 1 Remove the junction box and duct adaptor from the fan housing before installing the fan Remove the machine screw M4X6 and disconnect the electrical molex cable by pinching the tabs to insure the junction box and adaptor clear the fan housing when sliding the adaptor off the housing Fig 1 The fan positio...

Page 8: ...e Fig 7 8 Insert fan body and slide into adaptor until assembly TM the flange overlaps the Flex Z Fast bracket Secure TM the fan body to Flex Z Fast bracket by using 2 self drilling screws plug connector to receptacle and secure the fan body to adaptor by using machine screw M4X6 Fig 6 CAUTION Secure the duct adaptor to the fan housing with the machine screw M4X6 by re inserting and carefully scre...

Page 9: ... by using 2 self drilling screws plug connector to receptacle and secure the fan body to adaptor by using machine screw M4X6 Fig 14 Secure the duct adaptor to the fan housing with the machine screw M4X6 by re inserting and carefully screwing the adaptor to the housing Please insure the screw is appropriately placed so it does not strip the teeth nor come in contact with the TM Flex Z Fast bracket ...

Page 10: ...t wipe dry with clean cloth Fig 15 2 The grille should be dry after cleaning Fig 16 fan body using a vacuum Fig 17 fan body 5 Reinstall grille Routine maintenance must be done every year Please wear gloves during the cleaning work WARNING CAUTION Fig 17 FV 08 11VFM5 FV 08 11VF5 Fig 16 FV 08 11VFM5 FV 08 11VF5 ...

Page 11: ...ors and our fluorescent lamps do not create enough ambient heat to be subjected to these limitations The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Use the shortest straightest duct routing possible for best performance and avoid installing the fan with smaller ducts than recommended Insulatin around the ducts can reduce...

Page 12: ... Panasonic Corporation 2015 X0315 2095 08VF50420B Warning Concerning Removal of Covers The unit should be serviced by qualified technicians only Your product is designed and manufactured to ensure a minimum of maintenance Should your unit require service or parts call Panasonic Call Center at 1 866 292 7299 USA or 1 800 669 5165 Canada Two Riverfront Plaza Newark NJ 07102 ...

Reviews: