7

2.Wash and clean grille assembly.
    (Use non-abrasive kitchen detergent, wipe dry with 
    clean cloth.)(Fig.12)

3. Remove dust and dirt from fan body using a 
    vacuum cleaner. (Fig.13)
    

1. Remove grille assembly. (Squeeze mounting springs 
    and pull down carefully.)(Fig.11)

4. Using a cloth dampened with kitchen detergent, 
     remove any dirt from Fan Body. Wipe dry with 
    clean cloth. (Fig.14)

5. Replace grille assembly.

WARNING

CAUTION

Fig.12

Fig.13

Fig.14

Ceiling

Vacuum
cleaner

Ceiling

Glove

Fig.11

INSTALLATION FOR FV-07VBB1

3. Insert the grille assembly mounting springs into the 
    slots as shown and mount grille assembly to fan body .     
    (Fig.10)

Fig.10

Grille assembly

Grille assembly

Mounting 
spring

Slot

Slot

Glove

Glove

Mounting 
spring

Fan body

Fig.9

Claw

Rib

Plug connector

Ceiling

2. Secure the blower / motor assembly with 2 screw 
    and connect the molex plug connector from the 
    blower to the junction box. (Fig.9)

Before turning on the fan, make sure the 
connector is inserted at the correct position. 
Failure to properly connect will result in fan not 
working.(Fig.9)

The claw of connector must latch to the rib 
completely.(Fig.9) 

CAUTION

WARNING

The blower / motor assembly must be installed 
into housing can tightly by the 2 screw   . failure 
to secure with screw will affect the grounding. 

2 Screw
(ST4.2X8)

Blower / motor assembly

 

Adaptor 
flanges

Ceiling

Fig.8

1. Insert the blower / motor assembly by sliding it into   
    adaptor flanges.  Then press lock the blower / motor  
    assembly into the housing can until the blower   
    “clicks” into place for temporary fixation.  (Fig.8)

INSTALLATION FOR FV-07VBB1

Summary of Contents for FV-07VBA1

Page 1: ...6 INSTALLATION FOR FV 07VBA1 WALL MOUNTING c g a ...

Page 2: ......

Page 3: ...he motor grille assembly FV 07VBB1 must be installed with housing can FV 07VBA1 that is marked on the carton to indicate the suitability with this model Other motor grille assembly can not be substituted ...

Page 4: ... ST4 2X20 12 h h a a a a c b b m m m m m g a ...

Page 5: ... Code NEC Using UL approved wire nuts connect house power wires to ventilating fan wires The clamps of the adaptor should be clipped on fan housing correctly Install the adaptor and secure v duct before installing entilation junction box 3 Slide the clamps of the adaptor to the top of the fan housing and then snap the clamps of the adaptor into the bottom of the fan housing opening Fig 2 4 Remove ...

Page 6: ...t with mastic or approved foil tape A 4 inch circular duct is needed to connect to the relevant part of adaptor Fig 2 of page 5 6 Affix the junction box cover to junction box If the knock out hole is used B this step must be performed after step 8 7 Insert the tongue on the bottom of the junction box so that it is on the outside of the fan housing 8 Affix the junction box to the top of the fan hou...

Page 7: ...ting spring Slot Slot Glove Glove Mounting spring Fan body Fig 9 Claw Rib Plug connector Ceiling 2 Secure the blower motor assembly with 2 screw and connect the molex plug connector from the blower to the junction box Fig 9 Before turning on the fan make sure the connector is inserted at the correct position Failure to properly connect will result in fan not working Fig 9 The claw of connector mus...

Page 8: ... their rated air flow P0816 0 07VBA1M420 Fig 15 Properly insulate the area around the fan to minimize building heat loss and gain Fig 15 Loose fill or batt insulation can be placed directly over the fan housing in the attic Our fans and fan light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitor s fan light combination Our effic...

Reviews: