Panasonic FV-0511VQL1 Installation Instructions Manual Download Page 11

English

11

Make sure the temperature of LED unit has cooled 

down before maintenance

(cleaning) or replacement of lamp.

WARNING

MAINTENANCE (CLEANING) CONTINUED

Gloves

Ceiling

5. Reinstall grille.

4. Using a cloth dampened with kitchen detergent, remove

    any dirt from fan body. Wipe dry with clean cloth. (Fig.15)

Fig.15

Fig.16

lnsulation

4 inches or 6 inches roof jack, wall cap,

or soffit vent with backdraft damper
Mechanically connect duct to termination

and seal with mastic or approved foil

faced tape

2-3 ft straight run before elbow

Short piece of flexible duct helps

alignment and absorbs sound.

Clamps plus mastic or approved

foil faced tape at all flex joints

Foil tape tightly covers all metal

duct joints (glue PVC joints)

Properly insulate the area around the fan to

minimize building heat loss and gain. (Fig.16)

Loose fill or batt insulation can be placed

directly over the fan housing in the attic.

Our fans does not create excessive heat that

is a common problem with recessed light

fixtures or some competitor’s fan/light

combination. Our efficient, cool-running

motors do not create enough ambient heat

to be subjected to these limitations.

The ducting from this fan to the outside of

the building has a strong effect on the air flow, 

noise and energy use of the fan. Use the shortest,

straightest duct routing possible for best performance, and avoid installing the fan with smaller

ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold

growth. Fans installed with existing ducts may not achieve their rated air flow.

ln attic installation,

caulk box to drywall

PRACTICAL GUIDE TO INSTALLATION

Model No.

Air

direction

Exhaust

4 or 6

Exhaust

Voltage

(V)

Frequency

(Hz)

Noise

(sones)

Speed

(rpm)

Power

(W)

Weight

Ib.(kg)

Duct

diameter

(inches)

Air volume

at 0.1"WG

(CFM)

FV-0511VQL1

FV-1115VQL1

110

<0.3
<0.3

0.5

<0.3
<0.3

0.4

7.8

4.0

10.4

6.1

11.0

13.1

679
722
740

768
867

1016

110

130

6

60

120

60

120

150

50
80

9.9(4.5)

10.1(4.6)

Exhaust

FV-0511VQCL1

50

<0.3
<0.3

0.4

4.0
6.1

11.0

768
867

1016

80

4 or 6

60

120

110

10.1(4.6)

HVI Certified performance based on HVI Procedures 915, 916, and 920.

SPECIFICATIONS

Summary of Contents for FV-0511VQL1

Page 1: ...t after installation and this booklet should be presented to users Please retain this booklet for future reference Representative models FV 0511VQL1 FV 1115VQL1 FV 0511VQCL1 Ventilating Fan FV 1115VQL...

Page 2: ...d by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power f...

Page 3: ...ntrol device Solid state controls may cause harmonic distortion which can cause motor humming noise Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occ...

Page 4: ...orth America Two Riverfront Plaza Newark NJ 07102 Customer Call Center 1 866 292 7299 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This dev...

Page 5: ...0 5 7 8 151 13 330 7 1 2 190 1 1 4 30 4 1 2 114 3 7 8 100 12 304 3 3 8 86 13 1 4 15 1 2 336 394 16 1 2 18 3 4 419 480 21 1 4 23 1 2 540 597 10 1 4 261 13 330 3 7 8 100 1 1 2 37 Part name Grille Blade...

Page 6: ...ht Live Fan Live N Light Neutral Neutral lue White Black Green Main control circuit Fan body LED DC Motor Junction box AC120V 60Hz Power supply AC120V 60Hz Power supply White Black Live Light Live Fan...

Page 7: ...Pick A Flow speed options The Pick A Flow switch on the face of all WhisperCeiling ventilating fans allow the option to choose 50 80 110 CFM for the FV 0511VQL1 or 110 130 150 CFM for the FV 1115VQL1...

Page 8: ...as the spacing between joists and install to joists by drilling the other 2 tapping screws which have been fixed on it Fig 3 4 Remove junction box cover and secure conduit or stress relief to junction...

Page 9: ...her mounting spring into the slot as shown and mount grille to fan body Fig 9 12 Adjust Pick A Flow switch Refer to indication on FEATURE 9 Finish ceiling work Ceiling hole should be aligned with the...

Page 10: ...chine screw M4X8 to the suitable hole and not touch the Flex Z Fast bracket Please fix the screw carefully to avoid screw slip teeth TM Fig 12 CAUTION WARNING WARNING Disconnect power source before wo...

Page 11: ...oblem with recessed light fixtures or some competitor s fan light combination Our efficient cool running motors do not create enough ambient heat to be subjected to these limitations The ducting from...

Page 12: ...a minimum of maintenance Should your unit require service or parts call Panasonic Call Center at 1 866 292 7299 USA or 1 800 669 5165 Canada Printed in Mexico P0717 0 11QCL1420B PRODUCT SERVICE Panas...

Reviews: