2. Remove the screw as shown in step      of Fig.21.
    Remove the light cover as shown in step      of Fig.21.

MAINTENANCE     (REPLACEMENT OF LAMP)

1. Clean grille. (Don’t put into hot water. Use non-abrasive
    kitchen detergent, wipe dry with clean cloth) (Fig.17)

2. The grille should be dry after cleaning.
3. Remove dust and dirt from fan body using a vacuum
    cleaner. (Fig.18)
4. Using a cloth dampened with kitchen detergent, remove
    any dirt from fan body. Wipe dry with clean cloth. (Fig.19)
5. Reinstall grille.

Disconnect  power  source  before  working  on  unit.

Routine maintenance must be done every year. 
Please wear gloves during the cleaning work.

Never  use  gasoline,  benzene,  thinner  or  any  other
such  chemicals  for  cleaning  the  ventilating  fan.

Disconnect power source before working on unit. 
The lamp’s glass is fragile, be careful when the lamp 
is replaced.
Make sure the temperature of lens and lighting
unit has cooled down before maintenance
(cleaning) or replacement of lamp.

Do not immerse motor in water when cleaning.
Do not soak resin parts in water over 140 F (60 C).

WARNING

CAUTION

4. Install the 

 

LED lamps (CX-GU24-H-B, 7W) as shown in 

    step  1  and step  2  of Fig.9 (Page 9).

WARNING

Remove dust and dirt from light cover and lens, 
before replace the lamps.

The LED lamps should be replaced as the specified 
type. The supplied LED lamps are not intended for 
other use.

CAUTION

3. Replace the LED lamps (CX-GU24-H-B, 7W) as shown in 
    step  1  and step  2  of Fig.22.

Fig.17

Fig.18

Fig.19

11

5.  Install  light  cover.  (Fig.10  of  page  9)

1. Remove grille by pulling down one mounting spring 
    (Fig.20). Remove plug connector then pull down the other. 
    (For models plug-in FV-MSVK1 or FV-NLVK1: Pull down the 
    mounting spring that without lead wire passed side, and 
    remove motion sensor or LED night light as shown in Fig.20) 
    (Squeeze mounting spring and pull down carefully) 

Gloves

Gloves

Vacuum
cleaner

MAINTENANCE   (CLEANING)

Ceiling

Ceiling

Remove screw
(M4X8)

Light cover

Fig.22

Fig.21

LED lamp

Lens

Fig.20

Plug 
connector

Gloves

Grille

LED night light
(FV-NLVK1 only)

Clasp

Lighting 
unit

Motion sensor
(FV-MSVK1 only)

Mounting spring

Ceiling

Remove 
plug 
connector

Rib

Claw

Summary of Contents for FV-05-11VKSL1

Page 1: ...1 15VKL1 INSTALLATION INSTRUCTIONS Ventilating Fan Model No Contents FV 05 11VKSL1 FV 05 11VKL1 FV 11 15VKL1 Representative models 2 3 3 4 4 4 5 5 5 6 6 7 7 8 8 10 10 11 11 BACK COVER BACK COVER BACK...

Page 2: ...ibe the level of hazard injury and property damage caused when the denotation is disregarded and improper use is performed To reduce the risk of fire electric shock or injury to persons observe the fo...

Page 3: ...th a method which is not approved in the instructions WARNING This product must be properly grounded Do not use this fan with any solid state speed control device Solid state controls may cause harmon...

Page 4: ...gral transformer The motor is designed to have long operating life high dynamic response higher speed ranges with saving energy The grille covering the fan body is a spring loaded quick remove type A...

Page 5: ...ight Neutral Power supply AC120V 60Hz AC120V 60Hz Power supply Neutral Black Red Red Green Earth ground Green White White 114 C Fuse Thermally protected Hi Low switch When plug in Multi Speed module s...

Page 6: ...the high speed setting Selecting a particular TIME option will cause the fan to run for the selected amount of time before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM...

Page 7: ...ecessary to connect wall switch when only plug in FV NLVK1 fan can operate on high speed with wall switch control fan can also operate on low speed when used in combination with the FV VS15VK1 INDICAT...

Page 8: ...or from fan body by removing the machine screw M4X6 before installation Fig 1 IMPORTANT Remove the tape from damper and adaptor before installation As shown below The fan position between joists from...

Page 9: ...black Light Netural to white Netural to white Junction box Two red wires Connect to a general manual wall switch Earth ground to green INSTALLATION NEW CONSTRUCTION CONTINUED CAUTION CAUTION Machine s...

Page 10: ...fan body to adaptor by using machine screw M4X6 Fig 16 Secure machine screw M4X6 to the suitable TM hole and not touch the Flex Z Fast bracket Please fix the screw carefully to avoid screw slip teeth...

Page 11: ...t immerse motor in water when cleaning Do not soak resin parts in water over 140 F 60 C WARNING CAUTION 4 Install the LED lamps CX GU24 H B 7W as shown in step 1 and step 2 of Fig 9 Page 9 WARNING Rem...

Page 12: ...rection Exhaust Exhaust Exhaust 4 or 6 Exhaust Voltage V Voltage V Frequency Hz Frequency Hz Noise sones Noise sones Speed rpm Speed rpm Power W Power W Fan Fan Lighting unit Lighting unit Weight lb W...

Reviews: