![Panasonic FP7 Series Additional Functions Manual Download Page 26](http://html1.mh-extra.com/html/panasonic/fp7-series/fp7-series_additional-functions-manual_3529967026.webp)
High-level Instructions
3-10
Example 2) Specifying a device for the bit number
D: DT1, n: DT0
Bit
F E D C B A 9 8 7 6 5 4 3 2 1 0
DT0
0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 U8
DT1
0 1 0 1 1 0 0
0
0 1 1 1 0 0 0 0
Bit
F E D C B A 9 8 7 6 5 4 3 2 1 0
DT1
0 1 0 1 1 0 0
1
0 1 1 1 0 0 0 0
Precautions during programming
Difference between the FP7 and conventional models (such as FP2 or FP2SH);
The conventional models operate with only the lower four bits as valid even when the
specified [n] is out of the settable range. For the FP7, an operation error occurs when the
specified value is out of the range.
Flag operation
Name
Description
Latest error
(SR7)
Hold error
(SR8)
To be set in case of out-of-range values in indirect access (index modification, pointer access).
To be set when [n] is out of the range.
Summary of Contents for FP7 Series
Page 1: ...FP7 CPU Unit Ver 4 20 Additional Functions Manual 12 21 2015...
Page 3: ...1 Introduction of Ver 4 20...
Page 6: ......
Page 7: ...2 Basic Instructions...
Page 17: ...3 High level Instructions...
Page 29: ...4 FP2 FP2SH Program Conversion Function...
Page 36: ......
Page 37: ...5 MEWTOCOL COM...