background image

LP-V Series / LP-W Series

FAyb laser Marker

lP-V10U-c

lP-V15U-c

lP-W052U-c

item

Model

Work distance

190mm (note 1)

350mm (note 1)

17mm (note 1)

Marking method

Galvanometer scanning method

Marking laser

Fibre laser 

λ

 = 1.06µm, laser class 4

Ave. output

1W model

5W model

Max. output

15W (note )

7.5W (note )

Guide laser, pointer

Semiconductor fibre 

λ

 = 650nm, laser class 

Max. output

1mW

Marking range (mm)

90 x 90

160 x 160

55 x 55

Scanning speed

Max. 1000mm/s

Max. 6000mm/s

line speed

Max. 40m/min. (note 3)

Max. 10m/min (note 3)

character setting
(Height & width)

0. to 90mm

(adjustable in increments of 0.001 mm) 

0. to 160mm

(adjustable in increments of 0.001mm) 

0. to 55mm

(adjustable in increments of 0.001mm)

Marking spacing  
(spacing & pitch)

0 to 90mm 

(adjustable in increments of 0.001mm) 

Fan-like: +/-180° 

(adjustable in increments of 0.01°)

0 to 160mm 

(adjustable in increments of 0.001mm)

Fan-like: +/-180° 

(adjustable in increments of 0.01°)

0 to 55mm 

(adjustable in increments of 0.001mm) 

Fan-like: +/-180° 

(adjustable in increments of 0.01°)

Array of character

Straight line, fan-like, proportional/typewriter fonts, tilted and fan-like 

type of characters

Capital & small characters, figures, katakana, hiragana, kanji (JIS level 1 & level ),

symbols, user-defined characters (up to 50 types)

Bar codes

CODE39, CODE18, ITF/5, NW-7, JAN/UPC/EAN, RSS 14, RSS limited, RSS expanded

2D codes

QR, Micro QR, Data Matrix (ECC00)

logo/shape

BMP / DXF / HPGL / JPEG

cooling method

Forced-aired cooling

Supply voltage

90 to 13VAC or 180 to 64VAC (auto-changing), 50/60Hz

Power consumption

390VA or less (at 100VAC)

310 VA or less (at 100VAC)

input

Remote, trigger, encoder (A), encoder (B), shutter control, laser pumping, alarm reset, emergency stop, laser stop, confirmation end, 

number, timehold

output

Power supply (+1V), remote (RS3C, I/O), marking ready, marking, marking finished, laser pumping, warning, alarm,  

confirmation end, counter finish

Marking condition

Stationary, (for moving objects)

Functions

Marking order optimising • correction of intersection • counter marking 

• current date/time marking • expiry date • lot marking • logos/pictures • bold marking • logo data USB transfer 

• I/O monitor • system offset • common setting • laser pointer • font select • proportional marking • marking image display 

• operator adjustment • error code display • work image display • guide laser • power speed setting per line/logo file • step & repeat 

• time delay • serial data processing & marking • multilayered marking • backup • various processing functions

• dual pointer • marking time measurement • font creation/editing • power check/correction 

Emergency stop switch

Provided on the controller

Ambient temperature

0 to +40°C (no condensation or frost), storage: -10 to 60°C

Ambient humidity

35 to 85%RH (no condensation or frost)

Weight

Head: approx. 9kg

Controller: approx. kg

Head: approx. 10kg

Controller: approx. kg

Head: approx. 9kg

Controller: approx. kg

SPEciFicAtioNS

Note 1: The work distance has an individual error of ±.0mm from product to product.
Note : The maximum output refers to a maximum value of laser light output that a laser oscillator can output.
Note 3: The line speed varies depending on the application.

11/2007

Reviews: