background image

B

f

h

g

D

B

B

D

2

11

1

Pull the power cord 

e

 (from the 

power supply) and insert into the 
Pipe 

B

 hole as shown.

1

ܜႫᢟ

 

e

ȞՌႫྛȟٮԃყܚҰ஠Ϟ

ඨΣᏲᆓ

 

B

 

ЌȄ

2

Assemble the Pipe 

B

 to the Motor 

Assembly 

D

First, fi x the Pipe 

B

 to the motor 

shaft 

f

 as shown below.

Make sure that the Pipe hole and the 
motor shaft hole are aligned.
Then, ensure the switch 

g

 is 

pushed by switch lever 

h

.

 

Assemble Pipe to Motor 
Assembly

ġ

ಢ၆ᏲᆓՍีଢ଼ᐠಢӇ

2

CAUTION

Do not remove the switch 
lever at Pipe.

Fix the Pipe correctly to the 
motor shaft.
Can cause product not 
operate if switch has not been 
pressed down.

Do not press switch with 
other object, except using 
the switch lever given.

Can cause fi re, explosion, 
short circuit and electrical 
shock.
Can cause injury if the Ceiling 
Fan drops.

1

Kéo dây nguồn 

e

 (từ nguồn điện) 

và luồn vào lỗ Ống Trụ 

B

 như hình 

vẽ.

 

Lắp Ống Trụ với Bộ Động 

2

ಢ၆Ᏺᆓ

 

B

 

Սีଢ଼ᐠಢӇ

 

D

Ȅ

 

ॶӑȂ஠Ᏺᆓ

 

B

 

Ԋ၆ӵีଢ଼ᐠᙽଢ଼໅ġ

 

f

 

ΰȂԃήܚҰȄ

ጂۡᏲᆓЌᇄีଢ଼ᐠᙽଢ଼໅ЌᄇቆȄ
ณࡣȂҢ໠ᜰ؋

 

h

 

௰ଢ଼໠ᜰ

 

g

Ȅ

2

Lắp Ống Trụ 

B

 với Bộ Động Cơ 

D

Đầu tiên, bắt chặt Ống Trụ 

B

 vào 

trục động cơ 

f

 như hình dưới đây.

Cần đảm bảo lỗ Ống Trụ và lỗ trục 
động cơ được khớp với nhau.
Tiếp đến, cần kiểm tra xem công tắc  

g

 có được nhấn bởi cần công tắc  

h

 không.

ġġġݧཎ

ϸϼܶଶᏲᆓΰޟ໠ᜰ؋Ȅ

஠ᏲᆓғጂޟԊ၆ӵีଢ଼ᐠᙽ
ଢ଼໅ΰȄ
षؠᔆή໠ᜰџᏲम౰ࠢฒݲ
ᐇհȄ

ଶΟٺҢনԤޟ໠ᜰ؋оѴȂ
ϸϼᇄڏтݍՙӣਢ௰ࡸ໠
ᜰȄ

೻џᏲमЬخȂᛖࣔȂ฻ၯЅ
ႫᔞȄ
षӤਉ௬ဣོᏲमڧ༌Ȅ

LƯU Ý

Không được tháo cần công 
tắc ở Ống Trụ.  

Cố định Ống Trụ đúng cách 
với trục động cơ.
Có thể khiến quạt không hoạt 
động nếu công tắc không 
được ấn xuống. 

Không được đẩy công tắc 
bằng các vật khác trừ việc 
sử dụng cần công tắc được 
cung cấp.

Có thể gây cháy, nổ, đoản 
mạch và điện giật. 
Có thể gây chấn thương nếu 
Quạt Trần bị rơi.

How to install

ԃդԊ၆

Cách lắp đặt

3

Fix the Pipe and the Motor 
Assembly with the Ellipse Bolt 

G

, the P-R Washers 

H

, the Spring 

Washer 

I

, the Hexa Nut 

J

 and 

the Cotter Pin 

K

. (All taken from 

Part Set)
The slit 

i

 of the Ellipse Bolt 

position should be at top and 

bottom.
Bend the Cotter Pin 

K

 at last as 

shown.

3

ٺҢоήސࠢಢ၆Ᏺᆓᇄีଢ଼ᐠಢ
Ӈᐛ༫ᖳ੃

 

G

Ȃ

P-R 

წ୼

 

H

Ȃኆ

ᙋწ୼ġ

I

Ȃϲُלᖳൾ

 

J

 

໠ο᎛

 

K

ȄȞӒഋڥՌႭӇಢȟ

ᐛ༫ᖳ੃ޟዀᖁ

 

i

 

ᔖ՝ܻഥഋڷ

ۻᆒȄ
ശࡣܚҰ׷᠉໠ο᎛

 

K

Ȅ

3

Lắp Ống Trụ và Bộ Động Cơ bằng 
Bu-lông Hình Elip 

G

, Vòng Đệm 

P-R 

H

, Vòng Đệm Lò Xo 

I

, Đai 

Ốc Lục Giác 

J

 và Chốt Hãm Nêm 

K

. (Tất cả được lấy từ bộ ốc vít) 

Rãnh 

i

 của Bu-lông Hình Êlip 

cần ở phía trên cùng và dưới cùng.
Cuối cùng bẻ gập Chốt Hãm Nêm 

K

 xuống như hình vẽ.

Ceiling / 

Ј߆ݖ

 /

Trần Nhà

e

B

1

Summary of Contents for F-56NCL

Page 1: ...asonic product Before operating this product please read the instructions carefully and save this manual for future reference H ng D n S D ng v L p t Qu t Tr n C m n qu kh ch h ng mua s n ph m qu t Pa...

Page 2: ...install the Ceiling Fan at oily and dusty places Can cause re or electrical shock due to short circuit Do not install the Ceiling Fan near ammable areas such as a gas cooker Can cause re or electrica...

Page 3: ...d by the manufacturer its service agent or suitably quali ed persons Can cause injury if Ceiling Fan drops The Ceiling Fan suspension system should be examined at least once every two years Can cause...

Page 4: ...4 800 1200 N cm 250 300 N cm 10 MCB...

Page 5: ...5 2 3 1 15 4...

Page 6: ...o d ng ho c ng i c n ng l c th ch h p C th g y ch n th ng n u Qu t Tr n b r i Kh ng l p Qu t Tr n nh ng n i c nhi u d u m v b i C th g y h a ho n ho c ch p i n do o n m ch Kh ng l p t Qu t Tr n t i nh...

Page 7: ...R i Xu ng do b l c l Nh s n xu t i di n b o d ng ho c ng i c n ng l c th ch h p s th c hi n vi c g n h th ng treo C th g y ch n th ng n u Qu t Tr n b r i N n ki m tra h th ng treo Qu t Tr n t nh t ha...

Page 8: ...Ceiling Fan suspension system shall be examined at least once every two years 1 2 3 4 3 5 6 7 1 Ki m tra t nh tr ng c a Qu t Tr n h ng n m N u x y ra b t c v n g ng ng s d ng Qu t Tr n Sau li n h v i...

Page 9: ...1 E B C nh Qu t 3 F B Pu li 1 G Bu l ng H nh Elip 1 H V ng m P R 1 I V ng m L Xo 1 J ai c L c Gi c 1 K Ch t H m N m 1 L B i u Ch nh T c 1 Attention Do not place the Ceiling Fan directly on the oor Ca...

Page 10: ...keep it for step 4 4 on page 16 Remove the Lower Canopy screw c from the Pipe and keep it for step 6 2 on page 17 1 a B b 16 4 4 c 17 6 2 2 Insert the Lower Canopy C to the Pipe B Then insert the Uppe...

Page 11: ...u ti n b t ch t ng Tr B v o tr c ng c f nh h nh d i y C n m b o l ng Tr v l tr c ng c c kh p v i nhau Ti p n c n ki m tra xem c ng t c g c c nh n b i c n c ng t c h kh ng L U Kh ng c th o c n c ng t...

Page 12: ...00 N cm And the Cotter Pin must be xed into the Bolt hole and bent Can cause injury if the Ceiling Fan drops 800 1200 N cm C NH B O m b o ng Tr c v n ch t ho n to n v i tr c ng c L c v n bu l ng l 800...

Page 13: ...safety wire must be xed correctly and connected at all time Can cause injury if the Ceiling Fan drops Ensure that the angle a keeps 40 45 degree and the safety wire does not touch the motor surface a...

Page 14: ...at the position on Blade 6 Ki m tra sau khi l p t C c v t C nh Qu t 6 chi c d ng g n ch t B C nh Qu t u c v n ch t L p t m an to n v o v tr tr n C nh Qu t 3 1 Remove the Blade screws l 6 pieces silve...

Page 15: ...g the ceiling during installation In case U hook C is being used installation method is the same 3 2 U C L u B c 3 c th c th c hi n tr c b c 2 m b o gi Qu t Tr n t th th ng ng trong qu tr nh l p t C n...

Page 16: ...n s n ph m Green Yellow Earth Xanh V ng N i t Blue Neutral Xanh D ng Trung H a Brown Live N u D y N ng Double poles single throw switch Breaker Switch C ng t c hai c c C ng T c Ng t 4 Loop the safety...

Page 17: ...i t b ng t qu t kh i ngu n i n Vi c n i hay thay i d y d n i n hay d y ch nh t thi t ph i do ng i c chuy n m n ti n h nh tr nh c c s c c th x y ra S d ng lo i ng 227IEC53 RVV ho c ng c d y tr n 1 mm C...

Page 18: ...n for the Speed Regulator L is shown below 1 L 1 K ch th c c a B i u Ch nh T c L c minh h a d i y 2 Loosen the screw p from the speed regulator cover q Open the Speed Regulator L by lifting up the spe...

Page 19: ...les Khe 5 Connect the Live Wire D with the terminal t and tighten the terminal screws 6 To close the Speed Regulator L insert the two holes on top of the speed regulator cover q to the two protruding...

Page 20: ...odel T n Model F 56NCL Voltage V V i n p V 220 Frequency Hz Hz T n S Hz 50 Wattage W LOW W i n N ng W TH P 14 HIGH CAO 70 Rotation RPM LOW RPM Gia T c Quay RPM TH P 103 HIGH CAO 268 Air Velocity m min...

Reviews: