This product has been developed / produced 
for industrial use only.
Make sure that the power is off while wiring.
Take care that wrong wiring will damage the 
sensor.
Verify that the supply voltage variation is 
within the rating.
If power is supplied from a commercial 
switching regulator, ensure that the frame 
ground (F.G.) terminal of the power supply is 
connected to an actual ground.
In case noise generating equipment (switch-
ing regulator, inverter motor, etc.) is used in 
the vicinity of this product, connect the frame 
ground (F.G.) terminal of the equipment to an 
actual ground.
Do not run the wires together with high-volt-
age lines or power lines or put them in the 
same raceway. This can cause malfunction 
due to induction.
Do not use during the initial transient time 
(20ms) after the power supply is switched on.
Take care that the sensor is not directly exposed 
to fluorescent lamp from a rapid-starter lamp, a 
high frequency lighting device or sunlight etc., as 
it may affect the sensing performance.
Extension up to total 100m, or less, is possi-
ble with 0.3mm

2

, or more, cable. However, in 

order to reduce noise, make the wiring as 
short as possible.
Make sure that stress by forcible bend or pulling 
is not applied directly to the sensor cable joint.
This sensor is suitable for indoor use only.
Do not use this sensor in places having exces-
sive vapor, dust, etc., or where it may come in 
direct contact with water, or corrosive gas.
Take care that the sensor does not come in 
contact with water, oil, grease, organic sol-
vents, such as, thinner etc., or strong acid, 
and alkaline.

MOUNTING

3

٨

The tightening torque should be 0.39N

m or 

less.

EX-M2

M3 (length 16mm)
screw with washers

Sensor mounting bracket

MS-EX-1

 (Accessory)

٨

The tightening torque must not exceed the 
values given below.

EX-M2E

: 0.58N

m

EX-D200E

: 0.39N

m

EX-M2E, EX-D200E

M3 (length 16mm)
screw with washers

Sensor mounting bracket

MS-EX-1E

 (Accessory)

٨

٨

Never use this product as a sensing 
device for personnel protection.
In case of using sensing devices for 
personnel protection, use products 
which meet laws and standards, 
such as OSHA, ANSI or IEC etc., for 
personnel protection applicable in 
each region or country.

WARNING

SPECIFICATIONS

1

15% or less of operation distance

Hysteresis

Material

MS-EX-1E

 (Sensor mounting bracket): 1 set

Adjusting screwdriver: 1 pc.
Adjuster cap: 1 pc.

30mA or less

12 to 24V DC

r

10% Ripple P-P 10% or less

Supply voltage

Emitter: 20mA or less, Receiver: 20mA or less

Current consumption

0.04mm or less

0.1mm or less

Repeatability
(perpendicular to sensing axis)

0.14mm

2

 4-core (thru-beam type sensor emitter: 2-core) oil, heat and cold resistant cabtyre cable, 3m long

Cable

Enclosure: Black PBT (Glass fiber reinforced), Lens: Polycarbonate

Infrared LED (modulated)

Emitting element

IP65 (IEC)

Protection

-10 to +60

͠

 (No dew condensation or icing allowed), Storage: -30 to +70

͠

Ambient temperature

35 to 85% RH, Storage: 35 to 85% RH

Ambient humidity

Continuously variable adjuster

Sensitivity adjuster

Red LED (lights up when the output is ON), thru-beam type sensor: located on the receiver

Operation indicator

1ms or less

Response time

Light-ON or Dark-ON operation can be selected by changing the connection of the control input wire

Incorporated

Output

Output operation

Short-circuit protection

NPN open-collector transistor

Maximum sink current: 100mA

Applied voltage: 30V DC or less (between output and 0V)

Residual voltage: 1V or less (at 100mA sink current)

0.4V or less (at 16mA sink current)

MS-EX-1E

 (Sensor mounting bracket): 2 sets

MS-EX-1

 (Sensor mounting bracket): 2 sets

65g approx.

Emitter: 60g approx., Receiver: 60g approx. Emitter: 60g approx., Receiver: 65g approx.

Weight

Accessories

Side sensing

2m

200mm (Note 2)

Sensing range

EX-M2

EX-D200E

EX-M2E

Model No. (Note 1)

Item

Top sensing

Side sensing

Thru-beam

Diffuse reflective

Type

Ǿ

7mm or more opaque object (Note 3)

Opaque, translucent or transparent object

Sensing object

Notes: 1)

2)
3)

The model No. with suffix '

P

' shown on the label affixed to the thru-beam type sensor is the emitter, '

D

' shown on the label is the receiver.

Thru-beam type sensor emitter: 

EX-M2

غ

P

, Thru-beam type sensor receiver: 

EX-M2

غ

D

The sensing range of the diffuse reflective type sensor is specified for white non-glossy paper (200 

˜

 200mm) as the object.

If the slit mask (optional) is fitted, an object of 

EX-M2E

: 0.5

˜

3mm,

EX-M2

: 0.5

˜

2mm can be detected.

I/O CIRCUIT DIAGRAMS

4

*1: Selecting output operation be connecting 

control input wire (pink)

D

T

r

Z

D

12

24V DC

r

10%

Sensor circuit

Internal circuit

Users' circuit

Load

 (Black)
 Output (Note)

 (Blue) 0V

 (Pink) Control input
 (Note)

 (Brown) +V

100mA max.

*1

Connection

Connected to 0V

Light-ON

Light-ON

Dark-ON

Connected to +V

Dark-ON

Open

Dark-ON

Light-ON

Model No. 

EX-M2E

EX-M2

EX-D200E

Note: The thru-beam type sensor emitter does not incorporate.

Symbols...D

Z

D

T

r

: Reverse supply polarity protection diode
: Surge absorption zener diode
: NPN output transistor

Color code

ADJUSTMENTS

5

٨
Ԙ

ԙ

Ԛ

Beam alignment

Placing the emitter and the receiver face to face 
along a straight line, move the emitter in the up, 
down, left and right directions, in order to deter-
mine the range of the light received condition 
with the help of the operation indicator (red). 
Then, set the emitter at the center of this range.
Similarly, adjust for up, down, left and right an-
gular movement of the emitter.
Further, perform the angular adjustment for the 
receiver also.

Thru-beam type sensor (EX-M2E, EX-M2)

Sensing object

Emitter

Receiver

Operation indicator
(Red)

Diffuse reflective type sensor (EX-D200E)

After sensitivity adjustment is made, fit the ad-
juster cap.

Sensing object

Sensor

Adjuster cap

Operation indicator
(Red)

Sensitivity adjuster

٨

Sensitivity adjustment

Ԙ

ԙ

Ԛ

ԛ

Turn the sensitivity adjuster fully counter-
clockwise to the minimum sensitivity posi-
tion, MIN.

Place an object at the required distance 
from the sensor, turn the sensitivity adjust-
er gradually clockwise, and find out point
where the sensor changes to the light re-
ceived condition.

The position at the middle of points     and

  is the optimum sensing position.

Step Sensitivity adjuster

Description

Remove the object, turn the sensitivity adjuster 
further clockwise, and find out point      where 
the sensor changes to the light received 
condition again with only the background.

When the sensor does not go to the light 
received condition even if the adjuster is fully 
turned clockwise, point     is this extreme point.

Optimum position

Note: Use the accessory adjuster screwdriver to turn the distance 

adjuster slowly. Turning with excessive force will cause dam-
age the adjuster.

Thank you very much for purchasing Panasonic 
products. Please read this Instruction Manual 
carefully and thoroughly for the correct and 
optimum use of this product. Kindly keep this 
manual in a convenient place for quick reference.

Micro Photoelectric Sensor

EX

 Series

INSTRUCTION
MANUAL

MJE-EXM2 No.0034-43V

Reviews: