Setting up
16 - ENGLISH
3) Fix to the rack by using the commercially available screws
*1
(4 pcs).
*1: Use M5 or M6 screws for EIA standard rack.
▶
z
Securely tighten the screws.
Attention
z
During attachment, be careful that the interface box does not slip.
z
Be sure to fix the cables connected to the connecting terminals and the supplied AC adaptor nearby such as
the supports of the rack to avoid the cable and AC adaptor weights directly applied to the interface box.
z
Be sure that the temperature inside of the rack, of which the interface box is mounted, does not exceed 40°C
(104°F).
z
When mounting the interface box on the rack, leave 1 U (44.45 mm, 1.75") space at the upper side of the
interface box and be careful not to cover exhaust ports.
Mounting to the underside of the tabletop of the desk
1) Mount the supplied rack/table underside mounting bracket to the interface box (on
the left and right).
▶
z
Mount the bracket to the table underside mount screw holes at the lateral side of the interface box with the
supplied flat-head Phillips screws (3 pcs, each).
▶
z
Be sure to tighten at the specified torque.
Table underside mount
screw hole
Rack/table underside mounting bracket
2) Attach the AC adaptor and a mounting bracket for securing AC adaptor.
▶
z
For the attachment procedures, refer to “Connecting the AC adaptor” (
page 23).
▶
z
If the mounting bracket for securing AC adaptor is attached after the interface box is attached to the table
underside, excessive force may be applied to the mounting section on the table underside, which may
cause damage of the table or deformation of the interface box.
3) Fix to the underside of the tabletop by using the commercially available screws or
wood screws (4 pcs).
▶
z
Check that the tabletop is strong enough to bear the weight of the interface box.
▶
z
Securely tighten the screws and the wood screws.
Attention
z
When mounting the interface box to the underside of the tabletop of the desk, request the mounting operation
to the specialized engineer or to your dealer.
z
If the connecting terminals on the rear side become invisible when the interface box is attached to the table
underside, it is recommended to connect cables in advance before the interface box is attached to the table
underside.
z
During attachment, be careful that the interface box does not slip. Failure to observe this may cause a flaw on
the table.
z
When mounting to the underside of the tabletop of the desk, do not mount at a position, where an operator’s
leg may collide. Mount screws being loosened may cause the device to fall down, which will lead to damage to
or deformation of the device.
z
Be sure to fix the cables connected to the connecting terminals and supplied AC adaptors nearby such as the
legs of the desk to avoid the cable and AC adaptor weights directly applied to the interface box.
z
For heat release, leave 3 cm (1.2") or wider space at both sides of the interface box.
z
When using the interface box, do not place objects on the interface box. Be careful not to cover exhaust ports.