ENGLISH-3

Before replacing the lamp unit

 

z

Make sure to turn off the power before replacing the 

lamp unit. 

 

z

When switching off the projector, make sure 

to follow the procedures in “Switching off the 

projector” (

 page 3).

 

Checking the lamp unit to be 

replaced 

Check the status of the lamp 

indicators <LAMP1>/<LAMP2>.

 

z

The lamp unit corresponding to the lamp indicator 

that is lit in red is required to be replaced.

Main unit operating part

Power indicator

ON (G) / STANDBY (R) 

<Lamp indicator>

(LAMP1, LAMP2)

Power standby

<

  

> button

<MAIN POWER> switch 

Attention

 

z

Panasonic Connect Co., Ltd. shall not be 

responsible for damages or malfunctioning of the 

product due to the use of other than a Panasonic 

Connect Co., Ltd. lamp unit. Use only specified 

lamp units.

 

z

Do not use replacement lamp units (for portrait 

mode) and normal lamp units together. Check 

the product number on the label attached to the 

replacement lamp unit. 

 

z

A replacement lamp unit (for portrait mode) must 

be used when installing in a portrait orientation. 

 

z

Do not install the projector in any orientation other 

than portrait when using a replacement lamp unit 

(for portrait mode). 

 

z

Since the luminous lamp is made of glass, it may 

burst if dropped or hit with a hard object. Please 

handle with care.

 

z

Do not disassemble or modify the lamp unit.

 

z

When replacing the lamp unit, be sure to hold it 

by the handle because its surface is pointed and 

its shape is protruded.

 

z

The lamp may be burst. Replace the lamp unit 

carefully so that the broken pieces of the lamp 

glass will not scatter.

 

z

The lamp contains mercury. When disposing of 

used lamp units, contact your local authorities or 

dealer for correct methods of disposal.

 

z

Panasonic Connect Co., Ltd. recommends 

that the lamp unit be replaced by a specialized 

engineer. Contact your dealer. 

Note

 

z

A Phillips screwdriver is necessary when 

replacing the lamp unit.

 

z

The Multi Projector Monitoring & Control Software 

in the CD-ROM supplied with the PT-DZ13K 

series may not support the Model No. display of 

the replacement lamp unit (for portrait mode). 

Download the latest version of the software from 

“Multi Projector Monitoring & Control Software” on 

the website (https://panasonic.net/cns/projector/).

Switching off the projector

When the projector is operating, perform the follow-

ing steps to turn off the projector, and wait until the 

lamp unit cools off then make the replacement.

1)  Press the power standby <   > 

button. 

2)  Press 

◀▶

 to select [OK], and 

press the <ENTER> button. 

(Or press the power standby <   > 

button again.) 

 

z

Projection of the image will stop, and the 

power indicator <ON (G)/STANDBY (R)> on 

the projector lights in orange.

(The fan keeps running.)

3)  Wait until the power indicator  

<ON (G)/STANDBY (R)> of the 

projector lights in red (and the 

fan stops) for approximately 170 

seconds.

4) 

Press the <OFF> side of the <MAIN 

POWER> switch to turn off the 

power. 

Summary of Contents for ET-LAD320P

Page 1: ...for future use Model No ET LAD310A 1 pc ET LAD310AW 2 pcs ET LAD320P 1 pc ET LAD320PW 2 pcs TQZJ496 2 Replacement lamp unit Operating Instructions Model numbers ET LAD320P and ET LAD320PW are replacement lamp units to be used exclusively in portrait mode This lamp is used in projectors It is not intended to be used for indoor lighting of ordinary homes 2009 125 EC Product information for Turkey on...

Page 2: ...ws during the lamp unit replacement z Doing so can cause electric shocks burns or injury When replacing the lamp unit turn the power off and allow the lamp to cool for at least one hour before handling it z The cover reaches a very high temperature so failure to observe this will cause burns CAUTION Do not touch the fan with your fingers or any other parts of your body when replacing the lamp unit...

Page 3: ...e lamp unit be sure to hold it by the handle because its surface is pointed and its shape is protruded z The lamp may be burst Replace the lamp unit carefully so that the broken pieces of the lamp glass will not scatter z The lamp contains mercury When disposing of used lamp units contact your local authorities or dealer for correct methods of disposal z Panasonic Connect Co Ltd recommends that th...

Page 4: ...cover 3 Remove the lamp unit z Use a Phillips screwdriver to turn the lamp unit fixing screws two screws counterclockwise until they turn freely and then remove the lamp unit in the horizontal direction while holding the handle z Do not remove the screws other than the lamp unit fixing screws Lamp unit 2 Lamp unit 1 Handles Lamp unit fixing screws 4 Attach the lamp unit i Push in the new lamp unit...

Page 5: ...Minoshima Hakata ku Fukuoka 812 8531 Japan Importeur Panasonic Connect Europe GmbH Vertretungsberechtigter in der EU Panasonic Testing Centre Winsbergring 15 22525 Hamburg Deutschland Italiano Fabbricato da Panasonic Connect Co Ltd 4 1 62 Minoshima Hakata ku Fukuoka 812 8531 Giappone Importatore Panasonic Connect Europe GmbH Rappresentante autorizzato nell UE Panasonic Testing Centre Winsbergring ...

Page 6: ...rope GmbH Oficiālais pārstāvis ES Panasonic Testing Centre Winsbergring 15 22525 Hamburg Vācija Lietuvių Gamintojas Panasonic Connect Co Ltd 4 1 62 Minoshima Hakata ku Fukuoka 812 8531 Japonija Importuotojas Panasonic Connect Europe GmbH Įgaliotasis atstovas ES Panasonic Testing Centre Winsbergring 15 22525 Hamburgas Vokietija Magyar Gyártotta Panasonic Connect Co Ltd 4 1 62 Minoshima Hakata ku Fu...

Page 7: ...c Connect Europe GmbH Autorizovaný zástupca v EÚ Panasonic Testing Centre Winsbergring 15 22525 Hamburg Nemecko Slovenščina Proizvaja Panasonic Connect Co Ltd 4 1 62 Minoshima Hakata ku Fukuoka 812 8531 Japonska Uvoznik Panasonic Connect Europe GmbH Pooblaščeni zastopnik v EU Panasonic Testing Centre Winsbergring 15 22525 Hamburg Nemčija Türkçe Tarafından Üretilmiştir Panasonic Connect Co Ltd 4 1 ...

Page 8: ...t not be mixed with general household waste For proper treatment recovery and recycling of old products please take them to applicable collection points in accordance with your national legislation By disposing of them correctly you will help to save valuable resources and prevent any potential negative effects on human health and the environment For more information about collection and recycling...

Reviews: