Precautions with regard to safety

Replacing the lamp unit

WARNING

The lamp unit should only be replaced by a qualified 

technician.
When replacing the lamp, allow it to cool for at least one hour 

before handling it.

•  The lamp cover gets very hot, and contact with it can cause burns.

Notes on replacing the lamp unit

•  The light generating lamp is made of glass, so dropping it or allowing it to hit hard objects may 

cause it to burst. Be careful when handling the lamp.

•  Dispose of the removed the old lamp with the same care that would be taken with a fluorescent 

light.

•  A Phillips screwdriver is necessary for removing the lamp unit.

NOTICE:

For USA only

Hg-LAMP CONTAINS MERCURY, Manage in Accord with Disposal Laws,

See: 

www.lamprecycle.org

 or 1-888-411-1996

NOTE:

•  If the lamp usage time has passed 2 000 hours (when “LAMP POWER” has been set 

to “STANDARD” and when “AI” has been set to “OFF”), the projector will switch to 

standby mode after approximately 10 minutes of operation. The steps 

7

 to 

12

 after the 

replacement of the lamp unit should thus be completed within 10 minutes.

•  If the LCD projector is operating, turn off the power by the following procedure and wait 

for the lamp unit to cool down before carrying out replacement.

(1)  Hold down the POWER button for at least 0.5 seconds or press the POWER button 

twice to turn off the power. (The POWER button on the projector will illuminate orange 

while the cooling fan is still operating.)

(2) Disconnect the power cord after the POWER button on the projector illuminates red.

If the lamp has broken, ventilate the room immediately. Do not 

touch or bring your face close to the broken pieces.

•  Failure to observe this may cause the user to absorb the gas which was released when the 

lamp broke and which contains nearly the same amount of mercury as fluorescent lamps, and 

the broken pieces may cause injury.

•  If you believe that you have absorbed the gas or that the gas has got into your eyes or mouth, 

seek medical advice immediately.

•  Ask your dealer to replace the lamp unit and check the inside of the projector.

Caution

Summary of Contents for ET-LAB50

Page 1: ...aste handling For more information about collection and recycling of old products and batteries please contact your local municipality your waste disposal service or the point of sale where you purchased the items Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business users in the European Union If you wish to discard electrical and el...

Page 2: ...fter approximately 10 minutes of operation The steps 7 to 12 after the replacement of the lamp unit should thus be completed within 10 minutes If the LCD projector is operating turn off the power by the following procedure and wait for the lamp unit to cool down before carrying out replacement 1 Hold down the POWER button for at least 0 5 seconds or press the POWER button twice to turn off the pow...

Page 3: ... screws at the bottom of the projector and then remove the lamp unit cover 3 Use a Phillips screwdriver to loosen the two lamp unit fixing screws until the screws turn freely Then hold the handles of the lamp unit and gently pull the lamp unit out from the projector Handles Ⓐ Ⓑ NOTE Be sure to install the lamp unit and the lamp unit cover securely 5 Install the lamp unit cover and then use a Phill...

Page 4: ...ff the power Disconnect the mains lead after the POWER button on the projector illuminates red 12 This will reset the cumulative usage time for the lamp unit to 0 NOTE Press any button other than the POWER button to cancel the LAMP RUNTIME RESET screen Accessory Air filter 1 Printed in Japan NOTE Replace the air filter with the new filter which is supplied as an accessory while referring to the re...

Reviews: