background image

Anti-Pulse Power Resistors

(1) Rated Continuous Working Voltage (RCWV) shall be determined from RCWV=√Power Rating × Resistance Value, 

  or Limiting Element Voltage listed above, whichever less.

(2) Overload (Short-time Overload) Test Voltage (SOTV) shall be determined from SOTV=2.5×Power Rating or max.

 Overload Voltage listed above whichever less.

(3) Intermittent Overload Test Voltage (IOTV) shall be determined from IOTV=4.0×Power Rating or max. 

 Intermittent Overload Voltage listed above whichever less.

(4) Resistance tolerance is of use besides range listed, please inquire.

Power  Derating  Curve

For resistors operated in ambient  

temperatures above 70 °C,  power

rating shall be derated in accordance 

with the figure on the right.

■ As for Packaging Methods and / or cut formed leads,

    Please see Metal (Oxide) Film Resistors Packaging Methods

      Safety Precautions

The following are precautions for individual products. Please also refer to the common precautions for Fixed Resistors in this catalog.

1. Transient voltage

2. The resistors are covered with a special coating. Do not apply shock or vibration to them, or pinch them with long-nose pliers. 

Otherwise, the resistors may be damaged.

3. Do not apply excessive tension to the lead-connected sections. When bending the lead wire, do not apply excessive stress to the 

resistors and provide the wire with a natural curvature.

4. Do not brush the resistors during or after the cleaning process, which may be conducted after soldering.
  Otherwise, the coating film may be damaged.

If there is a possibility that the transient phenomenon (significantly high voltage applied in a short time) may occur or that a

high voltage pulse may be applied, make sure to evaluate and check the characteristics of Anti-Pulse Power Resistors

(hereafter called the resistors) mounted on your product rather than only depending on the calculated power limit or steady-

state conditions to complete the design or decide to use the resistors.

E24

E24

E24

E24

51 k

240 k

110 k

330 k

110 k

510 k

110 k

750 k

J (±5)

G (±2)

J (±5)

G (±2)

J (±5)

G (±2)

min.

max.

Resistance Range

(4)

(Ω)

(%)

J (±5)

G (±2)

Resistance

Tolerance

1000

500

500

700

700

800

1000

1000

500

800

1000

1000

1000

400

500

500

ERG3D

0.5

1

2

3

ERG12D

ERG1D

ERG2D

(W)

(V)

(V)

(V)

(VAC)

Ratings

Should a safety concern arise regarding this product, please be sure to contact us immediately.

1-Oct-21

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.

Standard

Resistance

Value

Part No.

Power Rating

at 70 °C

Limiting

Element

Voltage

(1)

Maximum

Overload

Voltage

(2)

Maximum

Intermittent

Overload

Voltage

(3)

Dielectric

Withstanding

Voltage

20

40

60

80

100

0

120

-

60

-

20 0 20

60 80 100

140

180

-

40

40

120

160

200

240

220

-

55 

70 

235 

130 

ERG12D

ERG1D ~

3D

Ra

te

Lo

ad(

%

)

Ambient Temperature

(

°C)