Products in the EBL512 system 

Control and Indication Equipment (c.i.e.) 

1548 

EBL512 CU 512 addresses  

1549 

EBL512 CU 512 addresses with printer 

1550 

EBL512 CU 512 addresses without front 

1572 

Cabinet for drawings 

Expansion boards, etc. 

1580 

8 conventional zones expansion board  (8 zone line inputs) 

1581 

8 relays expansion board 

1587 

External Fire Brigade Panel / DU interface board 

1598 

Web-server II  (SW: Web512 II or OPC512 II downloaded via a config. tool.) 

1590 

TLON connection board 

Display Units, etc. 

1728 

External Presentation Unit (EPU;  Designation texts in Swedish / English) 

1735 / 1736 

Alert Annunciation Unit (AAU;  Designation texts in Swedish / other language) 

1826 / 1828 

External Fire Brigade Panel (Ext. FBP;  Metal / ABS plastic housing) 

4513 

Cabinet for drawings (to be mounted together with 1826) 

Analog Detectors 

3308 

Analog heat detector * 

3309 

Analog heat detector, water proof 

3312 

Analog base  (For analog detectors) 

3312F 

Analog base  (For analog detectors)  Fast connectors. 

3312FL 

Analog base  (For analog detectors)  Fast connectors.  Ext. LED output. 

4300 

Analog multi detector * 

4301 

Analog photoelectric smoke detector * 

4313 

Analog base with isolator  (For analog detectors) 

 

* Detector to be plugged in Analog base 3312 or 4313. 

Conventional Detectors (connected to a COM loop via a zone line input, e.g. 3361) 

2324 

Base  (For conventional detectors) 

4318 

Combination heat detector **   (59 d rate-of-rise) 

4350 

Multi detector ** 

4352 

Photoelectric smoke detector ** 

4375 

Heat detector 60 degrees ** 

4376 

Heat detector 80 degrees ** 

6295 

Heat detector 60 degrees, water proof 

6296 

Heat detector 80 degrees, water proof 

6297 

Heat detector 100 degrees, water proof 

6298 

Heat detector 120 degrees, water proof 

 

** Detector to be plugged in Base 2324.

 

Intrinsically Safe Detectors (connected to COM loop via 2821) 

2810 

IS photoelectric smoke detector *** 

2811 

IS heat detector *** 

2812 IS 

base 

2820 Galvanic 

isolator 

2821 

IS Zone interface 

 

*** Detector to be plugged in IS base 2812.

 

Other peripheral devices 

2218 

External indicator (ext. LED) 

3314 

Address setting tool for the units connected to the COM loops 

3333 

Addressable manual call point 

3339 

Addressable manual call point, water proof 

3361 Addressable Multipurpose I/O unit  (Two inputs & two outputs) 
3364 

Addressable 2 voltage outputs unit 

3366 

External power supply (Addressable) 

3377 Addressable 

siren 

3378 

Addressable sounder base (for analog detectors) 

4582 

I/O Matrix board 

 

Summary of Contents for EBL512

Page 1: ..._____________________________________ Panasonic Electric Works 2008 08 20 Fire Security Technology Europe AB Page 1 of 6 Fire alarm system EBL512 An analog addressable fire alarm system for early detection without unwanted alarms www panasonic fire security com ...

Page 2: ... Power Supply The c i e can on four COM loops handle up to 512 input and or output units i e detectors manual call points general in and output units for free programmable user definable functions etc Each loop unit uses one address Conventional detectors can also be used in the system Control and Indication Equipment EBL512 EBL512 can work as a standalone unit or in a TLON network with up to 30 u...

Page 3: ...a certain level A large number of alarm algorithms is supported by the system and can be set for each analog detector individually Alert annunciation The output for the alarm transmitter can be delayed for immediate on site investigation of a fire alarm Individual detectors zones programmable outputs and outputs for the alarm transmitter can be individually disabled Internally and or externally co...

Page 4: ...e data can also be uploaded from the c i e Win512 is also used to download new software etc System overview C i e 1548 1826 Ext FBP 1828 Ext FBP 1735 36 AA unit 1728 EPU 4301 Analog photoelectric smoke detector 3333 3339 Addr Manual Call Point TLON Network 1590 board 1590 board 1590 board 1580 board 0 7 1587 board COM loop External PC system Web browser LAN or Internet 4300 Analog multi detector 3...

Page 5: ...ctors Fast connectors Ext LED output 4300 Analog multi detector 4301 Analog photoelectric smoke detector 4313 Analog base with isolator For analog detectors Detector to be plugged in Analog base 3312 or 4313 Conventional Detectors connected to a COM loop via a zone line input e g 3361 2324 Base For conventional detectors 4318 Combination heat detector 59 degrees rate of rise 4350 Multi detector 43...

Page 6: ..._____________________________________________ Panasonic Electric Works Fire Security Technology Europe AB Citadellsvägen 23 SE 211 18 Malmö Sweden Tel 46 0 40 697 70 00 Fax 46 0 40 697 70 99 info fste eu pewg panasonic com www panasonic fire security com ...

Reviews: