ADJUSTMENT PROCEDURES
Issue B
Section 7
MCUK011201C8
Revision 0
– 38 –
Service Manual
6.
Click the NEXT CAL button.
7.
Repeat steps 3, 4 and 5 until the NEXT CAL button is greyed out (i.e. cannot be selected).
8.
Click on the EXIT button when finished.
7.3.
RSSI
This procedure describes the calibration of RSSI on the mid-channel. This procedure must also be carried out for the low /
bottom channel and high / top channel.
The procedure is as follows:
1.
Connect the test equipment as shown in Figure 6.7:
2.
With the Channel Box software running, click on the RX CAL button
3.
Click on the RUN button.
4.
Click on the STEP button.
5.
Carry out the instructions described in the main dialogue window.
6.
Repeat steps 4 and 5 until the STEP button is greyed out (i.e. cannot be selected).
7.
Click on the EXIT button when finished.