11. Select PROGRAM TRIM PL MCH GSM.
Figure 6.12: Power level selection 2
12. Highlight the PL14 field and press ENTER.
Figure 6.13: Power level selection 3
13. Enter the value calculated in step 9 into the data field and then press ENTER.
14. Press ESC.
15. Re-measure the peak power.
16. Repeat steps 5 to 14 for the remaining power levels, in the following order:
PL6, PL9, and PL19.
Power levels between PL9 and PL6.
Power levels between PL14 and PL9.
Power levels between PL19 and PL14.
17. Calibrate PL15 (limits ±0.2 dB).