The laser diode in the optical pickup may break down due to
potential difference caused by static electricity of clothes or
human body.
So be careful of electrostatic break down during repair of the
optical pickup.
7.1. Handling of optical pickup
1. Do not subject the optical pickup to static electricity as it is
extremely sensitive to electrical shock.
2. To prevent the breakdown of the laser diode, an antistatic
shorting pin is inserted into the flexible board (FPC Board).
When removing or connecting the short pin, finish the job in
as short times as possible.
3. Be careful not to apply excessive stress to the flexible board
(FPC Board).
4. Do not turn the variable resistor (Laser power adjustment).
1. Human body grounding
Use the antistatic wrist strap to discharge the static
electricity from your body.
2. Work table grounding
Put a conductive material (sheet) or steel sheet on the area
where the optical pickup is placed and ground the sheet.
Caution
The static electricity of your clothes will not be grounded
through the wrist strap. So take care not to let your
clothes touch the optical pickup.
It has already been adjusted.
7 HANDLING PRECAUTIONS FOR TRAVERSE DECK
7.2. Grounding for electrostatic breakdown prevention
9
DVD-LS91PP
Summary of Contents for DVD-LS91PP
Page 4: ...18 3 Packing Accessories Exploded View 69 19 REPLACEMENT PARTS LIST 70 4 DVD LS91PP ...
Page 10: ...8 DISASSEMBLY REASSEMBLY AND SERVICE POSITION 10 DVD LS91PP ...
Page 11: ...8 1 Disassembly 11 DVD LS91PP ...
Page 27: ...27 DVD LS91PP ...
Page 28: ...28 DVD LS91PP ...
Page 42: ...42 DVD LS91PP ...
Page 48: ...DVD LS91PP 48 ...
Page 66: ...DVD LS91PP 66 ...
Page 67: ...18 EXPLODED VIEWS 18 1 Casing Parts Mechanism Section Exploded View 67 DVD LS91PP ...
Page 68: ...18 2 Mechanism Section Exploded View 68 DVD LS91PP ...
Page 69: ...18 3 Packing Accessories Exploded View 69 DVD LS91PP ...