19
Viewfinder displays
Display item
What is displayed
Status causing the display to appear
I
Cause of !LED
lighting display
(this item appears
only during a MODE
check)
SUPER-V
EXT ON
FIL No1
FIL wo No1
FIL NG
SHUT ON
WHITE ATW
WHITE PRE
GAIN wo 0dB
Displayed when SUPER-V is set to ON.
Displayed when EXTENDER is set to ON.
Displayed when FILTER is set to 1.
Displayed when FILTER is set to a number other than 1.
Displayed when FILTER is set to NG.
Displayed when SHUTTER is set to ON.
Displayed when ATW has been selected for AWB.
Displayed when the AWB switch has been set to PRE.
Displayed when a gain value other than 0 dB has been selected.
F
Calendar/clock status
switching display
D
“D” is displayed only when a VF DISPLAY setting has been selected. This is
to enable the user to differentiate between the screen displays when
“TIME+DATE” (see page 38) has been selected as the TIME/DATE setting
on <VF DISPLAY 2/2> and when “REC” has been selected as the TIME
STAMP setting (see page 35) on <VTR OPTION>.
G
Remaining
tape/recording inhibit
display
¢¢¢
min
=
END
=
INH
Normally, “
¢¢¢
min” is lighted, and it flashes when the tape is nearly at its end.
When the tape reaches the end, “
=
END” lights.
When recording is inhibited, “
=
INH” lights.
H
Safety zone markers
Corner:
3 types
Box:
3 types
16:9 full box: 3 types
The safety zone markers selected for 01 through 09 in SAFETY ZONE are
displayed. For further details, refer to the table for “SAFETY ZONE” (page
37) on the <MARKER/ZEBRA> sub-menu.
1
Extender display
2
INTERVAL REC status display
3
Time code display
4
Center marker
5
Message display
6
IRIS MODE switch status display
7
QUICK FOCUS display
8
Shutter speed display
9
LOW LIGHT warning display
:
Audio level meter display
;
VTR warning display/voltage warning display
<
FULL AUTO/SCENE FILE display
=
AWB color temperature fine adjustment amount display
>
Zoom display
?
AWB color temperature display
@
ATW, AWB channel display
A
F value display
B
Gain display
C
Filter display
D
Calendar/clock display
E
Remaining battery charge display
F
Calendar/clock status switching display
G
Remaining tape/recording inhibit display
H
Safety zone markers
≤
≤
–
–
≤
≤
≤
≤
≤
–
≤
≤
≤
–
–
–
–
–
–
–
–
≤
–
–
–
–
–
≤
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
≤
≤
–
≤
≤
–
≤
–
≤
≤
≤
–
≤
≤
≤
≤
≤
≤
≤
≤
≤
≤
–
≤
≤
–
–
≤
–
–
–
–
–
–
≤
≤
–
–
–
–
–
–
–
–
–
≤
–
≤
–
≤
–
≤
–
–
≤
–
≤
≤
≤
–
≤
≤
≤
≤
≤
≤
≤
≤
≤
≤
–
≤
–
Selecting the viewfinder screen display
Status displayed
when the
corresponding
status is
established
Display/non-
display selected
by
MARKER/ZEBRA
Display/non-
display selected
by VF DISPLAY
1/2 or 2/2
Display can be
cleared
Displayed
during playback