Panasonic DP-00 Series Instruction Manual Download Page 2

9

SPECIFICATIONS

 

Model No.

DP-00

1 2

-

3

-

4

-

5

1

1

: Low pressure type, 

2

: High pressure type

2

:  None: For outside of Japan, 

Z

: For inside of Japan

3

:  None: NPN output type, 

P

: PNP output type

4

:  None: With cable with a connector, 

J

: Without attachment

5

:  None: Without attachment

 

H1

: With sensor mounting bracket

 

H2

: With panel mounting bracket

Type

Low pressure type

High pressure type

Pressure type

Gauge pressure

Rated pressure range

-100.0 to +100.0kPa

0.000 to +1.000MPa

Displayable / settable 

pressure range

-101.0 to +101.0kPa

-0.010 to +1.010MPa

Pressure resistance

500kPa

1.5MPa

Applicable fluid

Air, Non-corrosive gas

Supply voltage

12 to 24V DC ±10% Ripple P-P 10% or less

Current consumption

30mA or less

Comparative 

output

<NPN output type>

NPN open-collector transistor

•   Maximum sink current: 50mA

•   Applied voltage: 30V DC or less

(between comparative output and 0V)

•   Residual voltage: 2V or less (at 50mA sink current)

<PNP output type>

PNP open-collector transistor

•   Maximum source current: 50mA

•   Applied voltage: 30 V DC or less

(between comparative output and + V)

•   Residual voltage: 2 V or less (at 50mA source current)

Output operation

Selectable either NO or NC, with key operation

Hysteresis

Refer to “

7

OUTPUT MODE AND OUTPUT OPERATION

Repeatability

±0.2% F.S.

(within ±4 digits)

±0.4% F.S.

(within ±4 digits)

Response time

2.5ms / 25ms / 250ms  Selected by key operation

Protection

IP40 (IEC)

Ambient temperature

0 to +50°C (No dew condensation)

Storage: -10 to +60°C

Ambient humidity

35 to 85% RH, Storage: 35 to 85% RH

Pollution degree

2

Overvoltage category

I

Usable altitude

2,000m or less

Temperature 

characteristics

(+20°C standard)

+10 to +40°C: 

Within ±1% F.S.

0 to +50°C: 

Within ±2.5% F.S.

+10 to +40°C: 

Within ±2% F.S.

0 to +50°C: 

Within ±5% F.S.

Material

Enclosure: PBT, LCD display: Acryl

Pressure port: Brass-nickel plating

Mounting screw section: Brass, O-ring: Nitrile rubber (NBR)

Key section: Polycarbonate

Weight

(Main body only)

Approx. 25g

Accessories

CN-14A-C2

 (Cable with a connector, 2m long) (optional for 

J

 type): 1 pc.

MS-DP1-1

 (Sensor mounting bracket) (only 

H1

 type): 1 pc.

MS-DP1-8

 (Panel mounting bracket) (only 

H2

 type): 1 pc.

10

CAUTIONS

 

● This product has been developed / produced for 

industrial use only.

 

● The product shall be used only within the rated 

pressure range.

 

●  Do not apply pressure exceeding the pressure resis-

tance. Otherwise, destruction of diaphragm occurs, 

preventing the product to perform normal operation.

 

● Make sure that the power supply is OFF while 

performing the wiring operation.

 

● Verify that the supply voltage variation is within 

the rating.

 

●  If power is supplied from a commercial switching reg-

ulator, ensure that the frame ground (F.G.) terminal of 

the power supply is connected to an actual ground.

 

● In case noise generating equipment (switching 

regulator, inverter motor, etc.) is used in the vicini-

ty of this product, connect the frame ground (F.G.) 

terminal of the equipment to an actual ground.

 

●  Do not use during the initial transient time (0.5 

sec.) after the power supply is switched ON.

 

●  When extending the cable, use a cable whose con-

ductor cross-sectional area is 0.3mm

2

 or more. The 

cable can be extended to up to 10m in total length.

 

●  Do not run the wires together with high-voltage lines 

or power lines or put them in the same raceway.

This can cause malfunction due to induction.

 

● The specification may not be satisfied in a strong 

magnetic field.

 

● This product is suitable for indoor use only.

 

● Take care that an excessive stress is not applied 

to the unit. Otherwise, pressure values may vary.

 

●  Take care that strong impact such as fall is not giv-

en to this product. Otherwise, it may be destroyed.

 

● Avoid dust, dirt, and steam.

 

● When cleaning, wipe off with a soft cloth that does 

not make dirt.

 

●  Take care that the product does not come into 

contact with organic solvents such as thinner.

 

● Take care that the product does not come into 

contact with oil or grease.

 

● Take care that the product does not come into 

contact with strong acid or alkaline.

 

● Do not insert wire into the pressure port. Other-

wise, destruction of diaphragm occurs, preventing 

the product to perform normal operation.

 

●  Make sure that stress by forcible bend or pulling 

is not applied to the sensor cable joint.

 

● Never disassemble or modify the product.

11

FACTORY SETTINGS

Type

Low pressure type

High pressure type

Operation setting

EASY mode

NO / NC setting

NC

NO

Threshold value

-50.0

0.500

Pressure unit

kPa

MPa

Display color

Red when ON, White when OFF

Response speed

2.5ms

12

MENU SETTING MODE

Display during output operation

Output OFF

Output ON

*:  Settings of output operation and display colors can be changed in "Dis-

play color setting mode" of "Setting mode."

Threshold value setting mode

RUN mode

After 10 sec.

After 10 sec.

or

1 sec.

1 sec.

2 sec.

2 sec.

*: Displayed only when hysteresis mode / window comparator mode is 

set.

Zero point adjustment mode

RUN mode

When adjustable

When unadjustable

2 sec.

3 sec.

Key lock setting / release mode

<Setting of key lock>

1 sec.

1 sec.

2 sec.

<Release of key lock>

1 sec.

1 sec.

2 sec.

*:  The key lock mark appears for 1 sec. when key operation is performed 

in RUN state with the key lock set (turns OFF in RUN state).

Detailed setting mode

2 sec.

RUN mode

Pressure unit setting mode (Note 1)

Operation setting mode

Settings initializing mode

NO / NC setting mode

mmHg (Note 3)

psi

bar

kgf/cm

2

kPa (Note 2)

EASY mode

No

Yes

NO

NC

Hysteresis 

mode

Window compar-

ator mode

2 sec.

1 sec.

1 sec.

1 sec.

1 sec.

2 sec.

2 sec.

2 sec.

Response speed setting mode

2.5ms

25ms

250ms

1 sec.

2 sec.

Display color setting mode

Red when ON

White when OFF

White when ON

Red when OFF

Always red

Always white

1 sec.

2 sec.

1 sec.

Notes: 1) The pressure unit setting mode is not displayed in the product 

intended for use in Japan.

 

2) “MPa” is used for high pressure type.

 

3) “mmHg” is used only for low pressure type.

 

4) When setting change has been made, do not turn OFF the pow-

er supply within 5 sec. after returning to RUN mode.

http://panasonic.net/id/pidsx/global

Overseas Sales Division (Head Office) 

2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan 

Phone: +81-568-33-7861  FAX: +81-568-33-8591

For sales network, please visit our website.

© Panasonic Industrial Devices SUNX Co., Ltd. 2015

PRINTED IN JAPAN