9
SPECIFICATIONS
●
Model No.
DP-00
1 2
-
3
-
4
-
5
1
:
1
: Low pressure type,
2
: High pressure type
2
: None: For outside of Japan,
Z
: For inside of Japan
3
: None: NPN output type,
P
: PNP output type
4
: None: With cable with a connector,
J
: Without attachment
5
: None: Without attachment
H1
: With sensor mounting bracket
H2
: With panel mounting bracket
Type
Low pressure type
High pressure type
Pressure type
Gauge pressure
Rated pressure range
-100.0 to +100.0kPa
0.000 to +1.000MPa
Displayable / settable
pressure range
-101.0 to +101.0kPa
-0.010 to +1.010MPa
Pressure resistance
500kPa
1.5MPa
Applicable fluid
Air, Non-corrosive gas
Supply voltage
12 to 24V DC ±10% Ripple P-P 10% or less
Current consumption
30mA or less
Comparative
output
<NPN output type>
NPN open-collector transistor
• Maximum sink current: 50mA
• Applied voltage: 30V DC or less
(between comparative output and 0V)
• Residual voltage: 2V or less (at 50mA sink current)
<PNP output type>
PNP open-collector transistor
• Maximum source current: 50mA
• Applied voltage: 30 V DC or less
(between comparative output and + V)
• Residual voltage: 2 V or less (at 50mA source current)
Output operation
Selectable either NO or NC, with key operation
Hysteresis
Refer to “
7
OUTPUT MODE AND OUTPUT OPERATION
”
Repeatability
±0.2% F.S.
(within ±4 digits)
±0.4% F.S.
(within ±4 digits)
Response time
2.5ms / 25ms / 250ms Selected by key operation
Protection
IP40 (IEC)
Ambient temperature
0 to +50°C (No dew condensation)
Storage: -10 to +60°C
Ambient humidity
35 to 85% RH, Storage: 35 to 85% RH
Pollution degree
2
Overvoltage category
I
Usable altitude
2,000m or less
Temperature
characteristics
(+20°C standard)
+10 to +40°C:
Within ±1% F.S.
0 to +50°C:
Within ±2.5% F.S.
+10 to +40°C:
Within ±2% F.S.
0 to +50°C:
Within ±5% F.S.
Material
Enclosure: PBT, LCD display: Acryl
Pressure port: Brass-nickel plating
Mounting screw section: Brass, O-ring: Nitrile rubber (NBR)
Key section: Polycarbonate
Weight
(Main body only)
Approx. 25g
Accessories
CN-14A-C2
(Cable with a connector, 2m long) (optional for
J
type): 1 pc.
MS-DP1-1
(Sensor mounting bracket) (only
H1
type): 1 pc.
MS-DP1-8
(Panel mounting bracket) (only
H2
type): 1 pc.
10
CAUTIONS
● This product has been developed / produced for
industrial use only.
● The product shall be used only within the rated
pressure range.
● Do not apply pressure exceeding the pressure resis-
tance. Otherwise, destruction of diaphragm occurs,
preventing the product to perform normal operation.
● Make sure that the power supply is OFF while
performing the wiring operation.
● Verify that the supply voltage variation is within
the rating.
● If power is supplied from a commercial switching reg-
ulator, ensure that the frame ground (F.G.) terminal of
the power supply is connected to an actual ground.
● In case noise generating equipment (switching
regulator, inverter motor, etc.) is used in the vicini-
ty of this product, connect the frame ground (F.G.)
terminal of the equipment to an actual ground.
● Do not use during the initial transient time (0.5
sec.) after the power supply is switched ON.
● When extending the cable, use a cable whose con-
ductor cross-sectional area is 0.3mm
2
or more. The
cable can be extended to up to 10m in total length.
● Do not run the wires together with high-voltage lines
or power lines or put them in the same raceway.
This can cause malfunction due to induction.
● The specification may not be satisfied in a strong
magnetic field.
● This product is suitable for indoor use only.
● Take care that an excessive stress is not applied
to the unit. Otherwise, pressure values may vary.
● Take care that strong impact such as fall is not giv-
en to this product. Otherwise, it may be destroyed.
● Avoid dust, dirt, and steam.
● When cleaning, wipe off with a soft cloth that does
not make dirt.
● Take care that the product does not come into
contact with organic solvents such as thinner.
● Take care that the product does not come into
contact with oil or grease.
● Take care that the product does not come into
contact with strong acid or alkaline.
● Do not insert wire into the pressure port. Other-
wise, destruction of diaphragm occurs, preventing
the product to perform normal operation.
● Make sure that stress by forcible bend or pulling
is not applied to the sensor cable joint.
● Never disassemble or modify the product.
11
FACTORY SETTINGS
Type
Low pressure type
High pressure type
Operation setting
EASY mode
NO / NC setting
NC
NO
Threshold value
-50.0
0.500
Pressure unit
kPa
MPa
Display color
Red when ON, White when OFF
Response speed
2.5ms
12
MENU SETTING MODE
Display during output operation
Output OFF
Output ON
*: Settings of output operation and display colors can be changed in "Dis-
play color setting mode" of "Setting mode."
Threshold value setting mode
RUN mode
After 10 sec.
After 10 sec.
or
1 sec.
1 sec.
2 sec.
2 sec.
*: Displayed only when hysteresis mode / window comparator mode is
set.
Zero point adjustment mode
RUN mode
When adjustable
When unadjustable
2 sec.
3 sec.
Key lock setting / release mode
<Setting of key lock>
1 sec.
1 sec.
2 sec.
<Release of key lock>
1 sec.
1 sec.
2 sec.
*: The key lock mark appears for 1 sec. when key operation is performed
in RUN state with the key lock set (turns OFF in RUN state).
Detailed setting mode
2 sec.
RUN mode
Pressure unit setting mode (Note 1)
Operation setting mode
Settings initializing mode
NO / NC setting mode
mmHg (Note 3)
psi
bar
kgf/cm
2
kPa (Note 2)
EASY mode
No
Yes
NO
NC
Hysteresis
mode
Window compar-
ator mode
2 sec.
1 sec.
1 sec.
1 sec.
1 sec.
2 sec.
2 sec.
2 sec.
Response speed setting mode
2.5ms
25ms
250ms
1 sec.
2 sec.
Display color setting mode
Red when ON
White when OFF
White when ON
Red when OFF
Always red
Always white
1 sec.
2 sec.
1 sec.
Notes: 1) The pressure unit setting mode is not displayed in the product
intended for use in Japan.
2) “MPa” is used for high pressure type.
3) “mmHg” is used only for low pressure type.
4) When setting change has been made, do not turn OFF the pow-
er supply within 5 sec. after returning to RUN mode.
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
For sales network, please visit our website.
© Panasonic Industrial Devices SUNX Co., Ltd. 2015
PRINTED IN JAPAN