7 Service Mode
7.1. (DVD) Self-Diagnosis and Special Mode Setting
7.1.1. (DVD) Self-Diagnosis Functions
Self-Diagnosis Function provides information for errors to service personnel by “Self-Diagnosis Display” when any error has
occurred.
U**, H** and F** are stored in memory and held.
You can check latest error code by transmitting [0] [1] of Remote Controller in Service Mode.
Automatic Display on FL will be cancelled when the power is turned off or AC input is turned off during self-diagnosis display is ON.
Error Code
Diagnosis contents
Description
Monitor Display
Automatic FL display
U30
Remote control code error
Display appears when main unit and remote
controller codes are not matched.
No display
“*” is remote controller code of the
main unit.
Display for 5 seconds.
U59
Abnormal
inner
temperature
detected
Display appears when the drive temperature
exceeds 70°C.
The power is turned off forcibly.
For 30 minutes after this, all key entries are
disabled. (Fan motor operates at the highest
speed for the first 5 minutes. For the
remaining 25 minutes, fan motor is also
stopped.) The event is saved in memory as
well.
No display
“U59 is displayed for 30 minutes.
U61
The unit is carrying out its
recovery process.
No display
U88
The unit is carrying out its
recovery process.
No display
U99
Hang-up
Displayed when communication error has
occurred between Main microprocessor and
Timer microprocessor.
No display
Displayed
is
left
until
the
[POWER] key is pressed.
H19
Inoperative fan motor
When inoperative fan motor is detected after
powered
on,
the
power
is
turned
off
automatically.
The event is saved in memory.
No display
No display
F00
No error information
Initial setting for error code in memory
(Error code Initialization is possible with error
code initialization and main unit initialization.)
No display
No display
F09
Serial
Communication
Error
between VHS Microprocessor
and Timer Microprocessor.
Please
confirm
Serial
Communication
terminal of Microprocessor.
NOTE:
If F09 appears just after updating Firmware,
pull off and insert AC plug, then it will
disappear.
No display
F34
Initialization error when main
microprocessor is started up
for program recording
When initialization error is detected after
starting up main microprocessor for program
recording,
the
power
is
turned
off
automatically.
The event is saved in memory.
No display
No display
F58
Drive hardware error
When drive unit error is detected, the event is
saved in memory.
No display
No display
F60
DVD module has not been
started.
Defect of Digital P.C.B.
Mode: No change
No display
15
DMR-ES35VP / DMR-ES35VPC
Summary of Contents for DMR-ES35VP
Page 6: ...2 2 Precaution of Laser Diode 6 DMR ES35VP DMR ES35VPC ...
Page 8: ...3 Service Navigation 3 1 Service Information 8 DMR ES35VP DMR ES35VPC ...
Page 9: ...4 Specifications 9 DMR ES35VP DMR ES35VPC ...
Page 10: ...5 Location of Controls and Components 5 1 Each Buttons 10 DMR ES35VP DMR ES35VPC ...
Page 11: ...11 DMR ES35VP DMR ES35VPC ...
Page 31: ...9 2 P C B Positions 31 DMR ES35VP DMR ES35VPC ...
Page 41: ...10 1 2 Checking and Repairing of Main P C B 41 DMR ES35VP DMR ES35VPC ...
Page 42: ...10 1 3 Checking and Repairing of RAM Digital P C B Module 42 DMR ES35VP DMR ES35VPC ...
Page 44: ...10 2 3 Items that should be done after replacing parts 44 DMR ES35VP DMR ES35VPC ...
Page 45: ...45 DMR ES35VP DMR ES35VPC ...
Page 60: ...60 DMR ES35VP DMR ES35VPC ...
Page 68: ...DMR ES35VP DMR ES35VPC 68 ...
Page 104: ...DMR ES35VP DMR ES35VPC 104 ...
Page 105: ...16 Exploded Views 16 1 Casing Parts Mechanism Section1 105 DMR ES35VP DMR ES35VPC ...
Page 106: ...16 2 Casing Parts Mechanism Section 2 106 DMR ES35VP DMR ES35VPC ...
Page 107: ...16 3 VHS Mechanism Section 107 DMR ES35VP DMR ES35VPC ...
Page 108: ...16 4 Packing Accessories Section 108 DMR ES35VP DMR ES35VPC ...