3.3.
Confirm “RAM-Drive Last Error” in Service Mode
Execute Service Mode
1. Press [REC], [CH UP] and [OPEN/CLOSE] simultaneously for 5 seconds when P-off.
FL Display:
*After finishing display “(9). Factor of Drive Error occurring”, press [0] [2] ~[1] [9] keys of the Remote Controller so that 19
memories can be displayed as maximum.
2. Press [4] [2] keys of remote controller.
Example of FL Display:
(1) Error Number is displayed for 5 seconds.
(2) Time when the error has occurred (1/2) is displayed for 5 seconds.
(3) Time when the error has occurred (2/2) is displayed for 5 seconds.
(4) Last Drive Error code No.1 is displayed for 5 seconds.
(5) Last Drive Error code No2. (1/2) is displayed for 5 seconds.