8 Service Mode
8.1. (DVD) Self-Diagnosis and Special Mode Setting
8.1.1. (DVD) Self-Diagnosis Functions
Self-Diagnosis Function provides information for errors to service personnel by “Self-Diagnosis Display” when any error has
occurred.
U**, H** and F** are stored in memory and held.
You can check latest error code by transmitting [0] [1] of Remote Controller in Service Mode.
Automatic Display on FL will be cancelled when the power is turned off or AC input is turned off during self-diagnosis display is ON.
Error Code
Diagnosis contents
Description
Monitor Display
Automatic FL display
U30
Remote control code error
Display appears when main unit and remote
controller codes are not matched.
No display
“*” is remote controller code of the
main unit.
Display for 5 seconds.
U59
Abnormal
inner
temperature
detected
Display appears when the drive temperature
exceeds 70°C.
The power is turned off forcibly.
For 30 minutes after this, all key entries are
disabled. (Fan motor operates at the highest
speed for the first 5 minutes. For the
remaining 25 minutes, fan motor is also
stopped.) The event is saved in memory as
well.
No display
“U59 is displayed for 30 minutes.
U61
The unit is carrying out its
recovery process.
No display
U88
The unit is carrying out its
recovery process.
No display
U99
Hang-up
Displayed when communication error has
occurred between Main microprocessor and
Timer microprocessor.
No display
Displayed
is
left
until
the
[POWER] key is pressed.
H19
Inoperative fan motor
When inoperative fan motor is detected after
powered
on,
the
power
is
turned
off
automatically.
The event is saved in memory.
No display
No display
F00
No error information
Initial setting for error code in memory
(Error code Initialization is possible with error
code initialization and main unit initialization.)
No display
No display
F09
Serial
Communication
Error
between VHS Microprocessor
and Timer Microprocessor.
Please
confirm
Serial
Communication
terminal of Microprocessor.
NOTE:
If F09 appears just after updating Firmware,
pull off and insert AC plug, then it will
disappear.
No display
F34
Initialization error when main
microprocessor is started up
for program recording
When initialization error is detected after
starting up main microprocessor for program
recording,
the
power
is
turned
off
automatically.
The event is saved in memory.
No display
No display
F58
Drive hardware error
When drive unit error is detected, the event is
saved in memory.
No display
No display
F60
DVD module has not been
started.
Defect of Digital P.C.B.
Mode: No change
No display
23
DMR-EH75VP
Summary of Contents for DMR-EH75VP
Page 6: ...2 2 Precaution of Laser Diode 6 DMR EH75VP ...
Page 8: ...3 Service Navigation 3 1 Service Information 8 DMR EH75VP ...
Page 9: ...4 Specifications 9 DMR EH75VP ...
Page 11: ...11 DMR EH75VP ...
Page 12: ...12 DMR EH75VP ...
Page 13: ...13 DMR EH75VP ...
Page 18: ...6 Location of Controls and Components 6 1 Each Buttons 18 DMR EH75VP ...
Page 19: ...19 DMR EH75VP ...
Page 40: ...10 2 P C B Positions 40 DMR EH75VP ...
Page 50: ...11 1 2 Checking and Repairing of Main P C B 50 DMR EH75VP ...
Page 52: ...11 1 3 Checking and Repairing of RAM Digital P C B Module 52 DMR EH75VP ...
Page 53: ...11 1 4 Checking and Repairing of HDD 53 DMR EH75VP ...
Page 57: ...57 DMR EH75VP ...
Page 120: ...17 1 2 Casing Parts Mechanism Section 2 120 DMR EH75VP ...
Page 121: ...17 1 3 VHS Mechanism Section 121 DMR EH75VP ...
Page 122: ...17 1 4 Packing Accessories Section 122 DMR EH75VP ...