Panasonic Digital Business System - Installation Manual
March 1997
Issue 5
55
VAU Dip-switch settings
There are two banks of DIP switches on the VAU. Their settings apply to both VAU answer circuits. Refer to the
figure 6 on page 8 for their locations. The options for these switches are given below.
1) Forced Transfer
Switch
Forced Transfer
Disable
Forced Transfer
Enable (default)
SW1-1
OFF
ON
Forced Transfer Disable :
When the extension to receive the call is busy the VAU will recover the call and play
the second message..
Forced Transfer Enable :
The call is released to camp onto the receiving extension regardless of its status. The
call will revert to the VAU after the time set in the system programming, when the second message will be played.
2) CCU Type
Switch
DBS (default)
S-DBS
SW1-2
OFF
ON
3) Message Sending Time
Switch
32 secs.
(One message)
16 secs. (default)
(Two messages)
SW1-3
OFF
ON
When 1 message of 32 seconds is selected the VAU will repeat the message when it would otherwise play
message 2.
This switch sets the message timings for both ports.
4) Extension Call
Switch
(default / fixed)
SW2-1
OFF
5) Incoming Call Answer Timer
Switch
8 secs.
16 secs.
32 secs.
Instant
(default)
SW2-2
OFF
OFF
ON
ON
SW2-3
OFF
ON
OFF
ON
Before this timer starts, the VAU requires 1 ringing cycle to determine the presence of the call.
6) DTMF Detection Timer
Switch
80 ms
40 ms
(default)
SW2-4
OFF
ON