background image

4

(EN)

Part names

Start/Stop 

button

Starts/Stops 

operation.

Enter button

Fixes the selected content.

Up/Down buttons

Selects an item.

Operation 

mode

 Setting information icon

• Only the partial settings can be checked on the 

top screen. To check all the settings (P.20)

• You can limit the number of icons to be 

displayed to simplify the display. (P.19)

Setting information icons displayed 

on the top screen

                        

   

• Icon details (P.21)

Control panel / Top screen

Note

Press centre

No glove

No pen

• If no operation is performed for an extended period, the backlight turns off to save electricity. 

(Press any button for illumination.)

Menu button

•  When pressed 

repeatedly during 

operation, this shows 

operating status 

confirmation, set temperature, 

operation mode, fan speed, flap, 

and the menu screen. (P.6)

•  When pressed while stopped, the 

menu screen is displayed. (P.8)

Under operation 

of nanoe™ X

LCD screen

Check the current 

operating status 

(P.6)

Set temperature

Appears when ECONAVI is being set to ON. 

(ECONAVI settings are possible only when fitted 

with ECONAVI panel/ECONAVI sensor.)

The control panel colour of CZ-RTC6W is white.

Summary of Contents for CZ-RTC6

Page 1: ...Page z z Safety precautions 3 z z Part names 4 Control panel Top screen 4 Screen display 5 Operation guide 5 z z Basic operations 6 z z Menu list 9 z z ECONAVI function 10 z z nanoe X function 13 z z...

Page 2: ...o comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential inst...

Page 3: ...his appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or...

Page 4: ...ress centre No glove No pen If no operation is performed for an extended period the backlight turns off to save electricity Press any button for illumination Menu button When pressed repeatedly during...

Page 5: ...Press z z To resume operation Press Key operations locked Prohibited Keys are locked so operations are not possible z z To return to the top screen Press Being centrally controlled operation is not po...

Page 6: ...o stop operation Press 2 Check the current operating status Press When no operation is performed for several seconds the display returns to the top screen Set temperature Fan speed Flap Operation mode...

Page 7: ...etting Press Press to finish Auto The mode is automatically switched to Cool or Heat to achieve the set temperature Operation modes that cannot be set are not displayed Heat Cool Dry Fan Auto Fan spee...

Page 8: ...with the flap movement Depending on the type of indoor unit and operation mode Flap can be set in 3 levels The flap display differs from the actual flap angle Menu 4 Select the menu item Press To ret...

Page 9: ...sound ON OFF P 18 6 Contrast Sets the screen contrast P 18 7 Backlight Sets the backlight brightness of the screen P 18 8 Language Sets the display language P 19 9 Display mode Changes the display of...

Page 10: ...re Heating Target temperature is 1 C lower than the set temperature Low activity Cooling Target temperature is 1 C higher than the set temperature Heating Target temperature is the same as the set tem...

Page 11: ...er a lapse of 3 hours since the room has been empty Operates in the Fan mode only Stops and resumes operations after human movements are detected Stops and will not resume operations even after human...

Page 12: ...s displayed To return to the top screen press 2 Select ECONAVI Press 3 Select ON or OFF Press Press to finish When ECONAVI is set to ON will appear on the top screen When the indoor unit is stopped wi...

Page 13: ...f nanoe X Under operation of nanoe X nanoe X For a fresher and cleaner environment nanoe X generates negative ions using the air in the room to give a healthy air It also reduces the smell in the room...

Page 14: ...to the top screen press 2 Select nanoeX Press 3 Select ON or OFF Press Press to finish When nanoe X is set to ON will appear on the top screen When the indoor unit is stopped will disappear ON OFF Not...

Page 15: ...top screen Filter sign reset 1 Display the menu screen When stopped Press When operating Press repeatedly until the menu screen is displayed To return to the top screen press 2 Select Filter sign Pres...

Page 16: ...the operation mode temperature needs to be set beforehand so that the outing function turns on the air conditioner with your desired operation mode temperature setting If the room temperature rapidly...

Page 17: ...layed To return to the top screen press 2 Select Outing function Press 3 Select Enable disable Press 4 Select Enable Press Enable Disable 5 Select Set limit temp Press 6 Set the temperature range 0 5...

Page 18: ...ss When operating Press repeatedly until the menu screen is displayed To return to the top screen press 2 Select the item to set Press Touch sound 3 Select ON or OFF Press Press to finish ON OFF Contr...

Page 19: ...n on the right Press Press to finish Default setting ENGLISH ENGLISH POLSKI ESPA OL ITALIANO DEUTSCH FRAN AIS Display mode 3 Select the display mode for the top screen Press Press to finish Detailed T...

Page 20: ...ation screen Press on the top screen Press and hold for 4 seconds or more 2 Select the icon Press Only icons currently being displayed on the screen are displayed here 3 Check the meaning of the icon...

Page 21: ...the gas heat pump air conditioner is used Energy saving is on to control energy consumption The operation capacity of the outdoor unit is restricted The temperature sensor of the remote controller is...

Page 22: ...rchase about the symptom and Model No Is displayed Alarm indication e g Defective indoor unit No z z If any of the following alarm indications appears stop operation once and restart approx 1 minute l...

Page 23: ...VI function is set to OFF Turn the ECONAVI function ON with the remote controller P 12 z z The indoor unit may not support the ECONAVI function If you turn the ECONAVI function ON with the remote cont...

Page 24: ...r use only Power Source DC16 V supplied from indoor unit Number of connected indoor units Indoor unit Up to 8 units Within group controlling Setting Information Indoor unit model name Indoor unit seri...

Page 25: ...ters etc or call the customer care toll free number https www panasonic com in corporate e waste management html Do s Don ts S No Do s Don ts 1 All electrical and electronic products are required to b...

Page 26: ...recovery and recycling of old products please take them to applicable collection points in accordance with your national legislation By disposing of them correctly you will help to save valuable resou...

Page 27: ...115191 11 3 8 800 200 21 00 a 30 03022 1 2 3 4 050010 192 3 Panasonic 7 727 330 88 07 8 800 0 809 809 050010 192 3 Panasonic 7 727 330 88 07 8 800 0 809 809 Information for users in the Republic of Ka...

Page 28: ...ation http www panasonic com Authorized representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany Contact in the UK Panasonic UK a branch of P...

Reviews: