Installation Instructions

High-spec Wired Remote Controller

Model No. 

CZ-RTC5A

English

Read through the Installation Instructions before you proceed 

with the installation.

In particular, you will need to read under the “Safety 

Precautions” on page 3.

Panasonic Corporation

1006 Kadoma, Kadoma City, Osaka, Japan

CV6233312187

Panasonic Corporation
http://www.panasonic.com

Contents

 

Part Names ....................................... 2

 

Supplied accessories ...................... 2

 

Safety Precautions ........................... 3

 

Speci

fi

 cations ................................... 4

 

Installation Precautions................... 5

 

Mounting ........................................... 7

Exposed type ................................ 7
Embedded type ............................ 8

 

Setting ............................................... 9

Language ..................................... 9
Clock ............................................ 9
Controller name ............................ 9
Service contact ........................... 10
RC. setting mode .........................11
Detailed settings ..........................11
Auto address .............................. 12
Set elec. consumption ................ 12

 

Con

fi

 rming Information ................. 13

 

Test Operation ................................ 14

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Summary of Contents for CZ-RTC5A

Page 1: ...Kadoma City Osaka Japan CV6233312187 Panasonic Corporation http www panasonic com Contents Part Names 2 Supplied accessories 2 Safety Precautions 3 Specifications 4 Installation Precautions 5 Mounting 7 Exposed type 7 Embedded type 8 Setting 9 Language 9 Clock 9 Controller name 9 Service contact 10 RC setting mode 11 Detailed settings 11 Auto address 12 Set elec consumption 12 Confirming Informati...

Page 2: ...links during alarm 8 Start Stop button Starts Stops operation 3 Enter button Fixes the selected content 4 Energy saving button Switches Energy saving Normal operation Right Left Note Press centre No pen No glove Supplied accessories Screw M3 8 x 16 2 Instructions 1 Quick Reference 1 Clamper 1 Remote control wiring is not supplied field supplied item AMP Air Conditioning www ampair co uk sales ampa...

Page 3: ...re installation Ask your dealer or professionals for installation and electric work This controller shall be installed in accordance with National Wiring Regulations Connect and fix the specified cables for wiring securely Do not allow the connection to be exposed to the external force of the cables Choose an installation location that sufficiently supports the weight of the remote controller CAUT...

Page 4: ...mance or occurrence of an alarm Remote controller wiring R1 R2 R1 R2 RC Refrigerant system 1 Outdoor unit Indoor unit Indoor unit For more information refer to the Operating Instructions in CD supplied Refrigerant system 2 Outdoor unit Model No CZ RTC5A Dimensions H 120 mm x W 120 mm x D 16 mm Weight 180 g Temperature Humidity range 0 C to 40 C 20 to 80 no condensation Indoor use only Power Source...

Page 5: ...ng diagram 1 2 R1 R2 Indoor unit Terminals for RC wiring RC RC wiring field supply No polarity Type of wiring Use cables of 0 5 to 1 25 mm2 Total wire length 500 m or less The wire length between indoor units should be 200 m or less Number of connectable units Remote controller Max 2 Indoor unit Max 8 Attention Use the field supplied RC wiring with at least 1 mm in thickness of insulation part inc...

Page 6: ...tion set this unit to Main CZ RTC2 CZ RTC4 CZ RE2C2 CZ RELC2 Using 1 indoor unit 1 2 1 2 R1 R2 RC wiring field supply No polarity Terminals for RC wiring RC main RC sub Indoor unit Using more than 1 indoor unit or heat exchange ventilation unit 1 2 1 2 R1 R2 R1 R2 R1 R2 R1 R2 RC main RC sub RC wiring field supply No polarity Terminals for RC wiring Indoor unit Indoor unit Indoor unit Indoor unit N...

Page 7: ...ll Flat blade screwdriver Insert the driver and slightly turn Bottom case Mounting Exposed type 1 3 2 Mount the top case Align the claws of the top case and then align the claws of the bottom case Preparation Make 2 holes for screws using a driver Mount the bottom case to the wall Cut here with a nipper and remove the burr with a file Claw 2 places Screw Supplied Hole for screw Claw 2 places Wall ...

Page 8: ...ottom case Avoid the wire being caught Claw 2 places Screw Supplied Hole for screw Claw 2 places Mount the bottom case to the wall Pass the wire through the hole in the centre of the bottom case Remote controller terminal board Remove the coating Approx 6 mm Make sure the wiring connection is in the correct direction Bottom case Back side Top case Back side Dimensions AMP Air Conditioning www ampa...

Page 9: ...er name 4 Set Repeat the same procedure for all characters Up to 16 characters Space is included in the number of characters To change the character type Select the character type with and press To enter space Select Space with and press To delete 1 character Select BS with and press 5 Select Conf Controller name AMP Air Conditioning www ampair co uk sales ampair co uk ...

Page 10: ... is included in the number of characters To change the character type Select the character type with and press To enter space Select Space with and press To delete 1 character Select BS with and press 5 Select Conf Up to 16 characters Space is included in the number of characters 6 Select on the screen for step 3 Contact number 7 Repeat the same procedure for all characters 8 Select Conf AMP Air C...

Page 11: ...ssword change Set the administrator password 0000 to 9999 0000 factory setting Detailed settings 3 Set Select the indoor unit number Code no and Set data Repeat Indoor unit number Set data Code no Code no Set data 31 Vent output setting Set this when connecting a commercially sold fan etc to the ventilation fan output FAN DRIVE 2P White on the indoor control board Dedicated cables optional are req...

Page 12: ...ore have passed Operate the units after Auto address is set and 1 minute and 30 seconds or more have passed Set elec consumption 3 Set Select the power supply voltage of outdoor units Note Set the power supply voltage of outdoor units to calculate electric consumption of the Power consumption monitor If the setting differs from the power supply voltage of outdoor units the electricity display erro...

Page 13: ...or units and outdoor units 3 Select Select the unit number 4 Confirm the content Pressing will return to the Maintenance func screen Service check This displays the alarm history 3 Confirm the content Information of 4 errors is displayed shows that no error has occurred Pressing will return to the Maintenance func screen To delete the error history press and select YES AMP Air Conditioning www amp...

Page 14: ...m the test operation 5 Finish the test operation Perform step 1 and 2 and then select OFF in step 3 TEST display disappears Any of the Heat Cool and Fan operations can only be performed Temperature cannot be changed The test operation mode is automatically turned off in 60 minutes To prevent continuous test operation Outdoor units do not operate for approx 3 minutes after the power is turned on or...

Page 15: ... Panasonic Corporation 2016 AMP Air Conditioning www ampair co uk sales ampair co uk ...

Reviews: