Page 1: ...NERS Before using your air conditioner please read this operation manual carefully and keep itfor future reference Outdoor Unit CU M1403KE CU M1803KE CU 3M2003KE Indoor Unit CS M903KE ENGLISH 357 0 DE...
Page 2: ...eeseeeseneenenees 10 11 Cooling Mode and Soft Dry Mode Operation 12 13 Setting the Timer s ssesesseseeseeecsessesseeesseeeneeeeneneenenencenenes 14 16 Convenient Operation Sleep Circulation Mode eect...
Page 3: ...te control Signal received sound two short beeps or one long beep Operation Indication Lamps Light up when the air conditioner is in operation Blinks on and off at the start of automatic operation Ver...
Page 4: ...be used Forced Operation Button Use when the remote control cannot be used Power switch Set to O OFF when not using the air conditioner for a long time Air Filter Remote Control Remote Control Two R03...
Page 5: ...peration Press once more to cancel Sleep Mode Auto Operation Operation Mode Selection Button Use to select the operation mode AUTOMATIC COOLING SOFT DRY CIRCULATION Airflow Direction Auto Contro l But...
Page 6: ...n Manual Two short beeps will sound Control Button Adjusts the airflow direction vertically Room Temperature Setting Button Use to set the room temperature Types of confirmation sound Stopping by pres...
Page 7: ...n be used for approximately one year Do not use rechargeable Ni Cd batteries because such batteries differ from standard dry cell batteries in shape dimensions and performance Be sure to replace the b...
Page 8: ...he letters of AM or PM will When changing the time blink The letters of AM or PM will blink Caution e The timer uses the current time as a reference If the time is not set correctly correct timer sett...
Page 9: ...receptor on the room air conditioner when operating Do not drop or throw the remote control Make sure that the signal path is not obstructed Do not place the remote conirol in a location that is expo...
Page 10: ...t going to be used for an extended period of time If the power switch is left at ON approximately 2 5 watts of electric power are used even if the main unit is turned off by remote control e If there...
Page 11: ...Operation Mode Soft Dry Operation Mode N c Circulation Operation Mode Automatic Operation e Each time the Operation Mode Selection button is pressed the indoor temperature sensor operates to automatic...
Page 12: ...decrease by 2 C Example of display When increasing When decreasing Helpful information Airflow Volume Notes The speed of the indoor fan is adjusted automatically to High ifthe compressor is in operati...
Page 13: ...ion Mode G Circulation Operation Mode Soft Dry Operation Soft Dry is a very gentle cooling operation consisting primarily of dehumidifying lt does not lower the room temperature very much The operatio...
Page 14: ...ndoor fan is adjusted automati cally to High if the compressor is in operation and to Medium speed ifthe compressor is stopped Circulation Operation Mode To change the room temperature Press the F of...
Page 15: ...ess the button to ad The timer indication lamp will vance the time and press the light up LED ORANGE Colour SJ button to go back Next to set the ON timer carry out steps 1 3 in Set ting the ON Timer E...
Page 16: ...dication lamp will advance the time and press light up the button to go back Next to set the OFF timer carry out steps 1 3 in Set ting the OFF Timer Example If the OFF timer has been set to 11 30 PM a...
Page 17: ...t the new day at a comfortable tempera ture When you return TV Lo Set the time you will come back with the Set the time you will go to sleep with the This will make the temperature pleasant when you r...
Page 18: ...will switch off Circulation Mode operation Sleep Mode operation When the temperature near the ceiling reaches the When the room temperature reaches the setting setting temperature Circulation Mode ope...
Page 19: ...air outlet vent automatically e Airflow Direction Adjustment ft UU Manual airflow direction operation Press the Airflow Direction Manual Control button continuously The vertical airflow direction lou...
Page 20: ...r adjustment during automatic airflow direction operation During cooling and Soft Dry operation the louver will automatically swing up and down from horizontal to 20 downward When cooling swings up an...
Page 21: ...d G Close the panel power switch on Operation button the air conditioner is at I ON gy 1 0 The operation indication lamp will blink for 20 seconds and then light up Press telower section Press the pan...
Page 22: ...filters e Re insert the air filters one each at right and left Be careful not to hurt your hands on metal parts If Air Cleaning Filters turn the same color as the sample color attached to the indoor u...
Page 23: ...ther dust from the louvers and the front panel time Using water above 40 C could cause deformation and or discoloration Volatile liquids such as thinner or benzene may damage the air conditioner Once...
Page 24: ...ons For air conditioners with a power plug stop operation and pull out the power plug Operate for 15 minutes Are the air outlet vents Is the drain hose If the difference in tempera and air intake vent...
Page 25: ...rotect the air conditioner Wait until the air conditioner begins operating During Sleep Mode operation the air conditioner repeatedly operates for a maximum of 10 minutes and stops for 20 minutes in o...
Page 26: ...the walls carpet furniture or clothing 4 in the room A sound like water flowing can This is the sound of refrigerant flowing be heard inside the air conditioner unit it seems that fog is coming out a...
Page 27: ...rature been Are the air filters dirty ti tly e Are the intake or outlet vents set incorrectly of the outdoor unit obstructed The air conditioner does not operate os c J Nh Has a circuit breaker been H...
Page 28: ...dead Are the batteries inserted in the incorrect and Are all windows and doors diveciane irections closed When there is a power failure Remote Control a The air conditioner will stay off Is the timer...
Page 29: ...e or twice every hour This is particularly recommended if you are using appliances which operate by gas Overcooling causes chills During summer if you are continually moving in and out of places where...
Page 30: ...e Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire wh...
Page 31: ...nnummer Handler Verkautsdatum Remarque i sis i eee Veuillez ne pas oublier de noter Le num ro de mod le 8 Le num ro de s rle Le nom du revendeur ae 2 ee ee ladated achat e baa Modeinummer Serienummer...