3

ENGLISH

FOR SYSTEMS WITHOUT COOL/HEAT CHANGEOVER REMOTE CONTROL

SWITCH (see figure 4)

1

Press the operation mode selector button several times and
select the operation mode of your choice;

Cooling operation

Heating operation

Automatic operation

Fan only operation

Note 

Automatic operation
In this operation mode, cool/heat changeover is
automatically conducted.

2

Press the on/off button.
The operation lamp lights up and the system starts
operation.

FOR SYSTEMS WITH COOL/HEAT CHANGEOVER REMOTE CONTROL

SWITCH (see figure 7)

1

Select operation mode with the cool/heat changeover
remote control switch as follows:

 

Cooling operation (see figure 7.1)

 

Heating operation (see figure 7.2)

Fan only operation (see figure 7.3)

2

Press the on/off button.
The operation lamp lights up and the system starts
operation.

Adjustment

For programming temperature, fan speed and air flow
direction, follow the procedure shown below.

 

3

Press the temperature setting button and program the
desired temperature.

Each time this button is pressed, the temperature
setting rises or lowers 1°C.

Note 

Set the temperature within the operation range.

The temperature setting is impossible for fan only
operation.

4

Press the fan speed control button and select the fan speed
of your preference.

5

Press air flow direction adjust button.

Refer to the chapter “Adjusting the air flow direction” for
details.

Stopping the system

6

Press the on/off button once again.

The operation lamp goes off and the system stops operation.

Note 

Do not turn off power immediately after the unit stops, but
wait for at least 5 minutes.

EXPLANATION OF HEATING OPERATION

Defrost operation (heatpump types only)

In heating operation, freezing of the outdoor unit coil
increases. Heating capability decreases and the system
goes into defrost operation.

The indoor unit fan stops and the remote controller
displays 

.

After maximum 10 minutes of defrost operation, the
system returns to heating operation again.

Hot start (heatpump types only)

In order to prevent cold air from blowing out of an indoor
unit at the start of heating operation, the indoor fan is
automatically stopped. The display of the remote
controller shows 

.

PROGRAM DRY OPERATION

The function of this program is to decrease the humidity
in your room with a minimum temperature decrease.

T h e   m i c r o   c o m p u t e r   a u t o m a t i c a l l y   d e t e r m i n e s
temperature and fan speed.

The system does not go into operation if the room
temperature is low.

FOR SYSTEMS WITHOUT COOL/HEAT CHANGEOVER REMOTE CONTROL

SWITCH (see figure 5)

1

Press the operation mode selector button several times and

select 

 ( program dry operation)

2

Press the on/off button

The operation lamp lights up and the system starts
operation.

3

Press the air flow direction adjust button. Refer to the

chapter “Adjusting the air flow direction” for details.

Stopping the system

4

Press the on/off button once again.

The operation lamp goes off and the system stops operation.

Note 

Do not turn off power immediately after the unit stops, but
wait for at least 5 minutes.

FOR SYSTEMS WITH COOL/HEAT CHANGEOVER REMOTE CONTROL

SWITCH (see figure 8)

1

Select cooling operation mode with the cool/heat

changeover remote control switch.

2

Press the operation mode selector button several times and

select program dry 

.

3

Press the on/off button

The operation lamp lights up and the system starts
operation.

4

Press the air flow direction adjust button. Refer to the

chapter “Adjusting the air flow direction” for details.

Stopping the system

5

Press the on/off button once again.

The operation lamp goes off and the system stops operation.

Note 

Do not turn off power immediately after the unit stops, but
wait for at least 5 minutes.

3VA11387-2A̲Eng

01.10.9, 7:54 PM

Page 3

Adobe PageMaker 6.5J/PPC

Summary of Contents for CU-8ME1XPA

Page 1: ...SPAÑOL ITALIANO E HNIKA NEDERLANDS PORTUGUES OPERATION MANUAL Model No Urban Multi Heat recovery inverter series CU 8ME1XPA CU 10ME1XPA PACKAGED AIR CONDITIONER Before operating this set please read these instructions completely ...

Page 2: ...le to changeover heat cool with the remote controller when this icon is displayed 4 Display air flow flap Refer to the chapter Operation procedure Adjusting the air flow direction 5 Display ventilation air cleaning This display shows that the total heat exchange and the air cleaning unit are in operation these are optional accessories 6 Display set temperature This display shows the temperature yo...

Page 3: ...ller with a hard pointed object The remote controller may be damaged Never pull or twist the electric wire of the remote controller It may cause the unit to malfunction Never inspect or service the unit by yourself Ask a qualified service person to perform this work To prevent refrigerant leak contact your Panasonic dealer When the system is installed and run in a small room it is required to keep...

Page 4: ...pability decreases and the system goes into defrost operation The indoor unit fan stops and the remote controller displays After maximum 10 minutes of defrost operation the system returns to heating operation again Hot start heatpump types only In order to prevent cold air from blowing out of an indoor unit at the start of heating operation the indoor fan is automatically stopped The display of th...

Page 5: ...gnated as the master remote controller and the display showing changeover under control vanishes The displays of other remote controllers show changeover under control PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one remote controller controls one indoor unit system Confirm the following if you...

Page 6: ...rature distribution inside a room becomes uneven It is necessary to clean the interior of the indoor unit Ask your Panasonic dealer for details on cleaning the unit This operation requires a qualified service person Immediately after the cooling operation stops and if the room temperature and humidity are low This is because warm refrigerant gas flows back into the indoor unit and generates steam ...

Page 7: ...utomatically restarts immediately after the power supply is recovered Check if no fuse has blown or breaker has worked Change the fuse or reset the breaker if necessary 2 If the system goes into fan only operation but as soon as it goes into heating or cooling operation the system stops Check if air inlet or outlet of outdoor or indoor unit is not blocked by obstacles Remove any obstacle and make ...

Page 8: ...3VA11387 2A EM01A146 0110 HT Matsushita Electric Industrial Co Ltd Web Site http www panasonic co jp global ...

Reviews: