140
21.1.3 CS-Z50UFRAW CU-Z50UBRA
Outdoor Air Temperature (°C)
Outdoor Air Temperature (°C)
Outdoor Air Temperature (°C)
Lo
w
Pres
sure (PSI)
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46
Outdoor Air Temperature (°C)
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46
8.00
5.00
6.00
7.00
1.200
1.000
0.800
0.600
0.400
0.200
0.000
4.00
5.00
6.00
7.00
3.00
2.00
1.00
0.00
174.045
145.038
116.030
87.023
58.015
29.008
0.000
4.00
3.00
2.00
1.00
0.00
14.0
12.0
10.0
8.0
6.0
4.0
2.0
0.0
Indo
or Disc
harge
Air Temperature (°
C)
Low Pressure (M
Pa)
C
urrent
(A)
Capac
ity
(
kW)
Outdoor Air
Temperature (°C)
5
16
25
35
8.80
9.88
11.24
11.75
46
12.83
Indoor Discharge
Air Temperature (°C)
Outdoor Air
Temperature (°C)
5
16
25
35
0.776 / 112.549
0.770 / 111.679
0.869 / 126.038
0.916 / 132.855
46
0.967 / 140.251
Low Pressure
(MPa) / (PSI)
Outdoor Air
Temperature (°C)
5
16
25
35
5.962
6.162
5.586
5.000
46
4.103
Capacity
(kW)
Outdoor Air
Temperature (°C)
5
16
25
35
4.37
4.17
5.04
5.59
6.20
46
6.87
4.84
5.39
6.00
6.67
Current (A)
230V
240V