![Panasonic CS-YS12MKV-7 Service Manual Download Page 54](http://html.mh-extra.com/html/panasonic/cs-ys12mkv-7/cs-ys12mkv-7_service-manual_1508267054.webp)
54
12.10 Cooling Overload Control
Pipe temperature limitation / restriction.
o
Detects the outdoor pipe temperature and carry out restriction / limitation below (Limit the compressor
operation frequency)
o
The compressor stops if outdoor pipe temperature exceeds 61°C.
o
If the compressor stops 4 times in 20 minutes, Timer LED blinks (“F95” indicated: Outdoor high pressure rise
protection)
12.11 Freeze Prevention Control
When indoor heat exchanger temperature is lower than 0°C continuously for 6 minutes, compressor will stops
operation.
Compressor will resume its operation 3 minutes after the indoor heat exchanger is higher than 13°C.
At the same time, indoor fan speed will be higher than during its normal operation.
If the indoor heat exchanger temperature is higher than 13°C for 5 minutes, the fan speed will return to its normal
operation.
12.12 Freeze Prevention Control 2
Control start conditions
o
During Cooling operation and soft dry operation
During Thermo OFF condition, Indoor intake temperature is less than 10°C or
Compressor stops for freeze prevention control
o
Either one of the conditions above occurs 5 times in 60 minutes.
Control
contents
o
Operation
stops
o
Timer LED blinks and “H99” indicated
12.13 Dew Prevention Control
To prevent dew formation at indoor unit discharge area.
This control will be activated if:
o
Cooling mode or Quiet mode is activated.
o
Remote control setting temperature is less than 25°C.
o
Fan Speed is at CLo or QLo.
o
Room temperature is constant (±1°C) for 30 minutes.
o
Compressor is continuously running.
Fan speed will be adjusted accordingly in this control.
o
Fan speed will be increased slowly if the unit is in quiet mode but no change in normal cooling mode.
12.14 Odor Cut Control
To reduce the odor released from the unit.
o
Start
Condition
AUTO FAN Speed is selected during COOL or DRY operation.
During freeze prevention control and timer preliminary operation, this control is not applicable.
o
Control
content
Depends on compressor conditions:
1. Compressor
OFF
→
Compressor ON.
The indoor unit fan stops temporarily and then starts to blow at minimum airflow for 30 seconds.
2. Compressor
ON
→
Compressor OFF.
The indoor unit fan stops for 90 seconds and then blows at minimum airflow for 20 seconds.
Summary of Contents for CS-YS12MKV-7
Page 11: ...11 3 Location of Controls and Components 3 1 Indoor Unit 3 2 Outdoor Unit 3 3 Remote Control ...
Page 12: ...12 4 Dimensions 4 1 Indoor Unit 4 1 1 CS YS9MKV 7 CS YS12MKV 7 ...
Page 13: ...13 4 1 2 CS YS18MKV 7 CS YS22MKV 7 ...
Page 14: ...14 4 2 Outdoor Unit 4 2 1 CU YS9MKV 7 4 2 2 CU YS12MKV 7 CU YS18MKV 7 ...
Page 15: ...15 4 2 3 CU YS22MKV 7 ...
Page 16: ...16 5 Refrigeration Cycle Diagram 5 1 CS YS9MKV 7 CU YS9MKV 7 CS YS12MKV 7 CU YS12MKV 7 ...
Page 17: ...17 5 2 CS YS18MKV 7 CU YS18MKV 7 CS YS22MKV 7 CU YS22MKV 7 ...
Page 18: ...18 6 Block Diagram 6 1 CS YS9MKV 7 CU YS9MKV 7 ...
Page 19: ...19 6 2 CS YS12MKV 7 CU YS12MKV 7 ...
Page 20: ...20 6 3 CS YS18MKV 7 CU YS18MKV 7 ...
Page 21: ...21 6 4 CS YS22MKV 7 CU YS22MKV 7 ...
Page 22: ...22 7 Wiring Connection Diagram 7 1 Indoor Unit 7 1 1 CS YS9MKV 7 CS YS12MKV 7 ...
Page 23: ...23 7 1 2 CS YS18MKV 7 CS YS22MKV 7 ...
Page 28: ...28 8 Electronic Circuit Diagram 8 1 Indoor Unit 8 1 1 CS YS9MKV 7 CS YS12MKV 7 ...
Page 29: ...29 8 1 2 CS YS18MKV 7 CS YS22MKV 7 ...
Page 30: ...30 8 2 Outdoor Unit 8 2 1 CU YS9MKV 7 ...
Page 31: ...31 8 2 2 CU YS12MKV 7 ...
Page 32: ...32 8 2 3 CU YS18MKV 7 ...
Page 33: ...33 8 2 4 CU YS22MKV 7 ...
Page 34: ...34 9 Printed Circuit Board 9 1 Indoor Unit 9 1 1 Main Printed Circuit Board ...
Page 36: ...36 9 1 3 Indicator Printed Circuit Board ...
Page 37: ...37 9 2 Outdoor Unit 9 2 1 Main Printed Circuit Board 9 2 1 1 CU YS9MKV 7 ...
Page 38: ...38 9 2 1 2 CU YS12MKV 7 ...
Page 39: ...39 9 2 1 3 CU YS18 22MKV 7 ...
Page 43: ...43 This can be used for left rear piping and bottom piping also ...
Page 87: ...87 15 2 3 To remove power electronic controller Figure 14 Figure 15 Figure 16 ...