Panasonic CS-YN18YKF Operating Instructions Manual Download Page 1

English

Operating Instructions

Air Conditioner

ACXF55-31540

١٧

-

٢

ﻞﻴﻐﺸﺘﻟﺍ

 

ﺕﺎﻤﻴﻠﻌﺗ

ﺪﻳﺮﺒﺘﻟﺍ

 

ﺯﺎﻬﺟ

 

ﻅﺎﻔﺘﺣﻻﺍﻭ

 

ﺔﻳﺎﻨﻌﺑ

 

ﻞﻴﻐﺸﺘﻟﺍ

 

ﺕﺎﻤﻴﻠﻌﺗ

 

ﺓﺀﺍﺮﻗ

 

ﻰﺟﺮﹸﻳ

 

،ﺓﺪﺣﻮﻟﺍ

 

ﻞﻴﻐﺸﺗ

 

ﻞﺒﻗ

.

ﻞﺒﻘﺘﺴﻤﻟﺍ

 

ﻲﻓ

 

ﺎﻬﻴﻟﺇ

 

ﻉﻮﺟﺮﻠﻟ

 

ﺎﻬﺑ

:

ﻥﺃ

 

ﺐﻴﻛﺮﺘﻟﺎﺑ

 

ﻢﺋﺎﻘﻟﺍ

 

ﻰﻠﻋ

 

ﺐﺠﻳ

 

،ﺐﻴﻛﺮﺘﻟﺍ

 

ﻞﺒﻗ

 

ﺐﻴﺘﹸﻜﻟﺍ

 

ﺍﺬﻬﺑ

 

ﻅﺎﻔﺘﺣﻻﺍ

 

ﻞﻴﻤﻌﻟﺍ

 

ﻦﻣ

 

ﺐﻠﻄﻳ

 

ﻢﺛ

 

،ﺐﻴﻛﺮﺘﻟﺍ

 

ﺕﺎﻤﻴﻠﻌﺗ

  

ﺃﺮﻘﻳ

.

ﻞﺒﻘﺘﺴﻤﻟﺍ

 

ﻲﻓ

 

ﻊﺟﺮﻤﻛ

.

ﺔﻴﻠﺧﺍﺪﻟﺍ

 

ﺓﺪﺣﻮﻟﺍ

 

ﻊﻣ

 

ﺓﺩﻮﺟﻮﻤﻟﺍ

 

ﺪﻌﺑ

 

ﻦﻋ

 

ﻢﻜﺤﺘﻟﺍ

 

ﺓﺪﺣﻭ

 

ﺔﻟﺍﺯﺈﺑ

 

ﻢﻗ

Operating Instructions
Air Conditioner

18-35

Before operating the unit, please read these operating 
instructions thoroughly and keep them for future reference.
Before installation, the installer should:
Read the Installation Instructions, then request the 
customer keep them for future reference.
Remove the remote control packed with the indoor unit.

Name and Address of Manufacturer:
Panasonic Appliances Air-Conditioning Malaysia Sdn. Bhd.
Shah Alam, Selangor, MALAYSIA

Name and Address of Importer:
Panasonic Marketing Middle East & Africa FZE
Jebel Ali, Dubai, UNITED ARAB EMIRATES

Model No.
Indoor Unit 

Outdoor Unit

CS-YN18YKF
CS-YN24YKF

CU-YN18YKF
CU-YN24YKF

Summary of Contents for CS-YN18YKF

Page 1: ...35 Before operating the unit please read these operating instructions thoroughly and keep them for future reference Before installation the installer should Read the Installation Instructions then request the customer keep them for future reference Remove the remote control packed with the indoor unit Name and Address of Manufacturer Panasonic Appliances Air Conditioning Malaysia Sdn Bhd Shah Alam...

Page 2: ... ﻋﻠﻰ ٥ ﻟﻤﺪﺓ ﻋﻠﻰ ﺍﺿﻐﻂ ﺍﻟﻮﻗﺖ ﻹﻇﻬﺎﺭ ﺎ ﹰ ﺒ ﺗﻘﺮﻳ ﹴ ﺛﻮﺍﻥ ﺎ ﹰ ﺣ ﺻﺒﺎ ﺳﺎﻋﺔ ١٢ ﻧﻤﻂ ﻋﻠﻰ ﺳﺎﻋﺔ ٢٤ ﺃﻭ ﹰ ﺀ ﻣﺴﺎ ﻟﻠﺘﺄﻛﻴﺪ SET ﺍﺿﻐﻂ ٢ ﺟﻬﺎﺯ ﺍﺳﺘﺨﺪﻡ ﺑﻌﺪ ﻋﻦ ﺍﻟﺘﺤﻜﻢ ﺃﻣﺘﺎﺭ ٨ ﻧﻄﺎﻕ ﻓﻲ ﻭﺣﺪﺓ ﻣﺴﺘﻘﺒﻞ ﻣﻦ ﻓﻲ ﺑﻌﺪ ﻋﻦ ﺍﻟﺘﺤﻜﻢ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺍﻟﻮﺣﺪﺓ ٢ AIR CONDITIONER ON OFF SET TIMER CANCEL OFF ON TEMP OFF ON MODE SLEEP AIR SWING JET STREAM FAN SPEED QUIET AIR CONDITIONER ON OFF TIMER CANCEL SLEEP AIR SWING JET STREAM FAN SPEED QUIET A B ...

Page 3: ...ﻢ TEMP DOWN ﻭ TEMP UP ﻋﻠﻰ ﺍﺿﻐﻂ ٣ ﺍﳌﻄﻠﻮﺑﺔ ﺍﳊﺮﺍﺭﺓ ﺩﺭﺟﺔ ﻟﺘﺤﺪﻳﺪ TEMP ﻟﻼﻋﻠﻰ ﻟﻼﺳﻔﻞ ﺍﻻﺧﺘﻴﺎﺭ ﻣﺪﻯ ﺩﺭﺟﺔ ٦٠ ﻣﺌﻮﻳﺔ ﺩﺭﺟﺔ ٣٠ ﺇﻟﻰ ﻣﺌﻮﻳﺔ ﺩﺭﺟﺔ ١٦ ﻓﻬﺮﻧﻬﺎﻳﺖ ﺩﺭﺟﺔ ٨٦ ﺇﻟﻰ ﻓﻬﺮﻧﻬﺎﻳﺖ ﺎ ﹰ ﺒ ﺗﻘﺮﻳ ﹴ ﺛﻮﺍﻥ ١٠ ﳌﺪﺓ ﻋﻠﻰ ﺍﺿﻐﻂ ﺃﻭ ﻣﺌﻮﻳﺔ ﺩﺭﺟﺔ ﳕﻂ ﻋﻠﻰ ﺍﳊﺮﺍﺭﺓ ﺩﺭﺟﺔ ﻹﻇﻬﺎﺭ ﻓﻬﺮﻧﻬﺎﻳﺖ ﻣﻦ ﺍﻟﻬﻮﺍﺀ ﻣﻜﻴﻒ ﺷﺮﺍﺀ ﻋﻠﻰ ﻟﻚ ﺷﻜﺮﺍ ﺑﺎﻧﺎﺳﻮﻧﻴﻚ ﻻﻏﺮﺍﺽ ﻫﻲ ﻴﺐ ﹼ ﺘ ﺍﻟﻜ ﻫﺬﺍ ﻓﻲ ﺍﻟﺘﻮﺿﻴﺤﻴﺔ ﺍﻟﺮﺳﻮﻣﺎﺕ ﺍﳊﻘﻴﻘﻴﺔ ﺍﻟﻮﺣﺪﺓ ﻋﻦ ﺗﺨﺘﻠﻒ ﺍﻥ ﻭﳝﻜﻦ ﻓﻘﻂ ﺍﻟﺸﺮﺡ ﺇﺷﻌﺎﺭ ﺩﻭﻥ ﻟﻠﺘﻐﻴﻴﺮ ﺮﺿﺔ ﻋﹸ ﻓﻬﻢ ...

Page 4: ...ﺍﺧﻠﻴﺔ ﺃﻭ ﺗﺴﺮﺏ ﺣﺪﻭﺙ ﺍﻟﻰ ﺍﳌﻌﺎﳉﺔ ﻓﻲ ﺍﻟﺼﺤﻴﺤﺔ ﻏﻴﺮ ﻭﺍﻟﻄﺮﻳﻘﺔ ﺍﳋﺎﻃﻲﺀ ﺍﻟﻨﺎﺭ ﺍﻧﺪﻻﻉ ﺃﻭ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺍﻟﺼﺪﻣﺔ ﺍﻱ ﺍﺳﺘﺨﺪﺍﻡ ﺣﻮﻝ ﺍﻟﻣﺨﺘﺺ ﺍﻟﻔﻨﻲ ﺃﻭ ﺍﳌﻔﻮﺽ ﺍﻟﻮﻛﻴﻞ ﺍﺳﺘﺸﺎﺭﺓ ﻳﺮﺟﻰ ﺍﻟﻰ ﺳﻴﺆﺩﻱ ﺼﺺ ﺍ ﺍﻟﺘﻮﻉ ﻏﻴﺮ ﺍﺧﺮ ﻧﻮﻉ ﺍﺳﺘﺨﺪﺍﻡ ﺍﻥ ﺍﳌﺒﺮﺩﺍﺕ ﻣﻦ ﻧﻮﻉ ﻭﺍﳉﺮﻭﺡ ﺍﳌﻨﺘﺞ ﺍﻧﻔﺠﺎﺭ ﺍﻭ ﺍﺗﻼﻑ ﺑﺨﻼﻑ ﻟﻠﺘﻨﻈﻴﻒ ﺃﻭ ﺍﳉﻠﻴﺪ ﺇﺯﺍﻟﺔ ﻋﻤﻠﻴﺔ ﻟﺘﺴﺮﻳﻊ ﻭﺳﺎﺋﻞ ﺍﻱ ﺗﺴﺘﺨﺪﻡ ﻻ ﺍﳌﺼﻨﻌﺔ ﺍﻟﺸﺮﻛﺔ ﻗﺒﻞ ﻣﻦ ﺑﻬﺎ ﺍﳌﻮﺻﻰ ﺗﻠﻚ ﺗﻠﻒ ﻳﺴﺒﺐ ﻗﺪ ﻣﺘﻮﺍﻓﻘﺔ ﻏﻴﺮ ﻣﻮﺍﺩ ﺍﺳﺘﺨﺪﺍﻡ ﺃﻭ ﺻﺎﳊﺔ ﻏﻴﺮ ﻃﺮﻳﻘﺔ ﺃﻱ ﺧﻄﻴﺮﺓ ﻭﺇﺻﺎ...

Page 5: ... ﺍﻟﺰﻣﻦ ﻣﻦ ﻃﻮﻳﻠﺔ ﻟﻔﺘﺮﺓ ﺍﻻﺳﺘﺨﺪﺍﻡ ﻋﺪﻡ ﺷﺪﻳﺪﺓ ﺑﺮﻕ ﻧﻮﺑﺎﺕ ﺣﺪﻭﺙ ﺗﻨﺒﻴﻪ ﺍﳋﺎﺭﺟﻴﺔ ﻭﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺍﻟﻮﺣﺪﺓ ﻣﺴﺤﻮﻕ ﺃﻭ ﺍﻟﺜﻨﺮ ﺃﻭ ﺍﻟﺒﻨﺰﻳﻦ ﺃﻭ ﺑﺎﳌﺎﺀ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺍﻟﻮﺣﺪﺓ ﻻﺗﻐﺴﻞ ﺍﻟﻮﺣﺪﺓ ﺗﺂﻛﻞ ﺃﻭ ﺗﻠﻒ ﻟﺘﻔﺎﺩﻱ ﺍﻟﺼﻘﻞ ﺍﳊﻴﻮﺍﻧﺎﺕ ﺃﻭ ﺍﻷﻃﻌﻤﺔ ﺃﻭ ﺍﻟﺪﻗﻴﻘﺔ ﺍﳌﻌﺪﺍﺕ ﺣﻔﻆ ﻓﻲ ﻻﺗﺴﺘﺨﺪﻡ ﺍﻟﻰ ﻳﺆﺩﻱ ﻗﺪ ﻫﺬﺍ ﻷﻥ ﺍﻷﺧﺮﻯ ﺍﳌﻮﺍﺩ ﺃﻭ ﺍﻟﻔﻨﻴﺔ ﺍﻷﻋﻤﺎﻝ ﺃﻭ ﺍﻟﻨﺒﺎﺗﺎﺕ ﺃﻭ ﺍﻟﺦ ﺍﳉﻮﺩﺓ ﺗﺮﺩﻱ ﺍﻟﻨﺎﺭ ﺍﻧﺘﺸﺎﺭ ﻟﺘﺠﻨﺐ ﺍﻟﻬﻮﺍﺀ ﺍﻧﺴﻴﺎﺏ ﻣﺠﺮﻯ ﺃﻣﺎﻡ ﺍﺣﺘﺮﺍﻕ ﺃﺟﻬﺰﺓ ﻻﺗﺴﺘﺨﺪﻡ ﻟﺘﻔﺎﺩﻱ ﺍﳌﺒﺎﺷﺮ ﺍﻟﻬﻮﺍﺀ ﺗﻴ...

Page 6: ... ﺩﺍﺋﻤ ﺍﻟﺘﺄﻛﺪ ﻳﺠﺐ ﺑﺈﻏﻼﻕ ﻗﻢ ﺍﻷﻧﺎﺑﻴﺐ ﺗﺨﺰﻳﻦ ﻋﻨﺪ ﺎ ﹰ ﺃﻳﻀ ﺍﻷﻧﺎﺑﻴﺐ ﺗﺪﺧﻞ ﻻ ﺫﻟﻚ ﺇﻟﻰ ﻭﻣﺎ ﺍﻟﻼﺻﻖ ﻭﺍﻟﺸﺮﻳﻂ ﺍﻟﻀﻐﻂ ﻃﺮﻳﻖ ﻋﻦ ﺑﺈﺣﻜﺎﻡ ﺍﻟﻔﺘﺤﺔ R410A ﻟـ ﻣﺸﺎﺑﻪ R32 ﻣﻊ ﺍﻟﺘﻌﺎﻣﻞ ﺫﻟﻚ ﻭﺍﻹﺻﻼﺡ ﻭﺍﻟﺼﻴﺎﻧﺔ ﺍﻟﺘﺸﻐﻴﻞ ﻋﻤﻠﻴﺎﺕ ﺇﺟﺮﺍﺀ ﻳﺠﺐ ﻭﻣﻌﺘﻤﺪﻳﻦ ﻣﺪﺭﺑﲔ ﻣﻮﻇﻔﲔ ﺑﻮﺍﺳﻄﺔ ﺍﻟﺘﺒﺮﻳﺪ ﻏﺎﺯ ﻭﺍﺳﺘﻌﺎﺩﺓ ﺍﻟﻨﺤﻮ ﻭﻋﻠﻰ ﻟﻼﺷﺘﻌﺎﻝ ﺍﻟﻘﺎﺑﻠﺔ ﺍﳌﺒﺮﺩﺍﺕ ﺍﺳﺘﺨﺪﺍﻡ ﻓﻲ ﻭﺍﻋﺘﻤﺎﺩ ﺗﺪﺭﻳﺐ ﻳﺠﺐ ﺍﳌﺼﻨﻌﺔ ﺍﻟﺸﺮﻛﺔ ﻗﺒﻞ ﻣﻦ ﺑﻪ ﺍﳌﻮﺻﻰ ﻋﻠﻰ ﺻﻴﺎﻧﺔ ﺃﻭ ﺗﺼﻠﻴﺢ ﺃﻭ ﻋﻤﻠﻴﺔ ﺑﺈﺟﺮﺍﺀ ﻳﻘﻮﻣﻮﻥ ﺃﻓﺮﺍﺩ ﺃﻱ ﺑﺎﳌﻌﺪﺍﺕ ﻣﺮ...

Page 7: ...ﻬﻮﻳﺔ ﻓﺘﺤﺎﺕ ﺑﻨﺪ ﻓﻲ ﺍﻟﻮﺍﺭﺩﺓ ﺍﻻﺣﺘﻴﺎﻃﺎﺕ ﺍﺗﺒﻊ ﺍﳌﻨﺘﺞ ﻣﻦ ﺍﻟﺘﺨﻠﺺ ﻋﻨﺪ ﺍﻟﻮﻃﻨﻴﺔ ﻟﻠﻮﺍﺋﺢ ﻭﺍﻣﺘﺜﻞ ٢١ ﺭﻗﻢ ﺻﺤﻴﺢ ﺑﺸﻜﻞ ﻟﻠﺘﻌﺎﻣﻞ ﺍﶈﻠﻴﺔ ﺍﻟﺒﻠﺪﻳﺔ ﲟﻜﺎﺗﺐ ﺎ ﹰ ﺩﺍﺋﻤ ﺍﺗﺼﻞ ﺍﻟﺼﻴﺎﻧﺔ ٢ ﺍﻟﺼﻴﺎﻧﺔ ﻣﻮﻇﻔﻮﺍ ١ ٢ ﺑﺎﻧﺘﻈﺎﻡ ﻭﺻﻴﺎﻧﺘﻪ ﻋﻠﻴﻪ ﻭﺍﻹﺷﺮﺍﻑ ﺍﻟﻨﻈﺎﻡ ﻓﺤﺺ ﻳﺘﻢ ﰎ ﺍﻟﺬﻳﻦ ﻭﺍﳌﻌﺘﻤﺪﻳﻦ ﺍﳌﺪﺭﺑﲔ ﺍﻟﺼﻴﺎﻧﺔ ﻣﻮﻇﻔﻲ ﻗﺒﻞ ﻣﻦ ﺍﳌﺴﺆﻭﻝ ﺍﻟﻄﺮﻑ ﺃﻭ ﺍﳌﺴﺘﺨﺪﻡ ﻗﺒﻞ ﻣﻦ ﺗﻜﻠﻴﻔﻬﻢ ﺣﺠﻢ ﻣﻊ ﻳﺘﻮﺍﻓﻖ ﺍﻟﺘﺒﺮﻳﺪ ﻟﻐﺎﺯ ﺍﻟﻔﻌﻠﻲ ﺍﻟﺸﺤﻦ ﺃﻥ ﻣﻦ ﺗﺄﻛﺪ ﻏﺎﺯ ﻋﻠﻰ ﲢﺘﻮﻱ ﺍﻟﺘﻲ ﺍﻷﺟﺰﺍﺀ ﺗﺮﻛﻴﺐ ﻓﻴﻬﺎ ﻳﺘﻢ ﺍﻟﺘﻲ ﺍﻟﻐﺮ...

Page 8: ...ﻳﺠﺐ ﺍﻟﻌﻤﻞ ﺗﻨﻔﻴﺬ ﻓﻴﻬﺎ ﺇﻃﻼﻗﻪ ﻳﺘﻢ ﻣﺒﺮﺩ ﺃﻱ ﺗﺸﺘﻴﺖ ﻋﻠﻰ ﺍﻟﺘﻬﻮﻳﺔ ﺗﻌﻤﻞ ﺃﻥ ﻳﺠﺐ ﺍﳉﻮ ﻓﻲ ﺎ ﹰ ﺧﺎﺭﺟﻴ ﻃﺮﺩﻩ ﻭﻳﻔﻀﻞ ﺁﻣﻦ ﺑﺸﻜﻞ ﺍﻟﺘﺒﺮﻳﺪ ﻣﻌﺪﺍﺕ ﻓﺤﺺ ٧ ٢ ﺗﻜﻮﻥ ﺃﻥ ﻳﺠﺐ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺍﳌﻜﻮﻧﺎﺕ ﺗﻐﻴﻴﺮ ﺣﺎﻟﺔ ﻓﻲ ﺍﻟﺼﺤﻴﺤﺔ ﻭﺍﳌﻮﺍﺻﻔﺎﺕ ﻟﻠﻐﺮﺽ ﻣﻨﺎﺳﺒﺔ ﺑﺎﻟﺸﺮﻛﺔ ﺍﳋﺎﺻﺔ ﻭﺍﻟﺘﻀﻠﻴﺢ ﺍﻟﺼﻴﺎﻧﺔ ﺇﺭﺷﺎﺩﺍﺕ ﺍﺗﺒﺎﻉ ﻳﺠﺐ ﺍﻷﻭﻗﺎﺕ ﺟﻤﻴﻊ ﻓﻲ ﺍﳌﺼﻨﻌﺔ ﻟﻠﺸﺮﻛﺔ ﺍﻟﻔﻨﻲ ﺍﻟﻘﺴﻢ ﺍﺳﺘﺸﺮ ﺷﻚ ﻓﻲ ﻛﻨﺖ ﺇﺫﺍ ﺍﳌﺴﺎﻋﺪﺓ ﻋﻠﻰ ﻟﻠﺤﺼﻮﻝ ﺍﳌﺼﻨﻌﺔ ﺍﻟﺘﻲ ﺍﻟﺘﺮﻛﻴﺒﺎﺕ ﻋﻠﻰ ﺍﻟﺘﺎﻟﻴﺔ ﺍﻟﻔﺤﻮﺻﺎﺕ ﺇﺟﺮﺍﺀ ﻳﺠﺐ ﻟﻼﺷﺘﻌﺎﻝ ﺍﻟﻘﺎﺑﻠ...

Page 9: ... ﺃﻥ ﻣﻦ ﺗﺄﻛﺪ ﺑﻴﺌﻴﺔ ﺗﺄﺛﻴﺮﺍﺕ ﺃﻱ ﺃﻭ ﺍﳊﺎﺩﺓ ﺍﳊﻮﺍﻑ ﺃﻭ ﺍﻻﻫﺘﺰﺍﺯ ﺃﻭ ﺍﻟﺰﺍﺋﺪ ﺍﻟﻀﻐﻂ ﺃﺧﺮﻯ ﺿﺎﺭﺓ ﺃﻭ ﺍﻟﺘﻘﺎﺩﻡ ﺁﺛﺎﺭ ﺍﻻﻋﺘﺒﺎﺭ ﻓﻲ ﺎ ﹰ ﺃﻳﻀ ﺍﻟﻔﺤﺺ ﻳﺄﺧﺬ ﺃﻥ ﻳﺠﺐ ﻛﻤﺒﺮﺳﻮﺭ ﺍﻟﻀﻮﺍﻏﻂ ﻣﺜﻞ ﻣﺼﺎﺩﺭ ﻣﻦ ﺍﳌﺴﺘﻤﺮ ﺍﻻﻫﺘﺰﺍﺯ ﺍﳌﺮﺍﻭﺡ ﺃﻭ ﻟﻼﺷﺘﻌﺎﻝ ﺍﻟﻘﺎﺑﻠﺔ ﺍﳌﺒﺮﺩﺍﺕ ﻋﻦ ﺍﻟﻜﺸﻒ ٦ ﻣﺼﺎﺩﺭ ﺍﺳﺘﺨﺪﺍﻡ ﺍﻟﻈﺮﻭﻑ ﻣﻦ ﻇﺮﻑ ﺃﻱ ﲢﺖ ﻳﺠﻮﺯ ﻻ ﺗﺴﺮﻳﺒﺎﺕ ﻋﻦ ﺍﻟﻜﺸﻒ ﺃﻭ ﺍﻟﺒﺤﺚ ﻓﻲ ﺍﶈﺘﻤﻠﺔ ﺍﻻﺷﺘﻌﺎﻝ ﺍﻟﺘﺒﺮﻳﺪ ﻏﺎﺯ ﺁﺧﺮ ﻛﺎﺷﻒ ﺃﻱ ﺃﻭ ﺍﻟﻬﺎﻟﻴﺪ ﺷﻌﻠﺔ ﺍﺳﺘﺨﺪﺍﻡ ﻳﺠﻮﺯ ﻻ ﹰﺎ ﻓ ﻣﻜﺸﻮ ﺎ ﹰ ﺒ ﻟﻬ ﻳﺴﺘﺨﺪﻡ ﻣﻘﺒﻮﻟﺔ ﺍﻟﺘﺎ...

Page 10: ...ﺙ ﺣﺪﻭﺙ ﻋﺪﻡ ﻣﻦ ﺗﺄﻛﺪ ﺍﻟﺸﺤﻦ ﻣﻌﺪﺍﺕ ﺍﺳﺘﺨﺪﺍﻡ ﺍﻹﻣﻜﺎﻥ ﻗﺪﺭ ﻗﺼﻴﺮﺓ ﺍﳋﻄﻮﻁ ﺃﻭ ﺍﳋﺮﺍﻃﻴﻢ ﺗﻜﻮﻥ ﺃﻥ ﻳﺠﺐ ﻓﻴﻬﺎ ﺍﳌﻮﺟﻮﺩ ﺍﻟﺘﺒﺮﻳﺪ ﻏﺎﺯ ﻛﻤﻴﺔ ﻟﺘﻘﻠﻴﻞ ﺎ ﻭﻓﻘﹰ ﻣﻨﺎﺳﺐ ﻭﺿﻊ ﻓﻲ ﺍﻷﺳﻄﻮﺍﻧﺎﺕ ﺣﻔﻆ ﻳﺠﺐ ﻟﻠﺘﻌﻠﻴﻤﺎﺕ ﺑﻐﺎﺯ ﺍﻟﻨﻈﺎﻡ ﺷﺤﻦ ﻗﺒﻞ ﺍﻟﺘﺒﺮﻳﺪ ﻧﻈﺎﻡ ﺗﺄﺭﻳﺾ ﻣﻦ ﺗﺄﻛﺪ ﺍﻟﺘﺒﺮﻳﺪ ﺇﻥ ﺍﻟﺸﺤﻦ ﺍﻛﺘﻤﺎﻝ ﻋﻨﺪ ﺍﻟﻨﻈﺎﻡ ﻋﻠﻰ ﻣﻠﺼﻖ ﺑﻮﺿﻊ ﻗﻢ ﺑﺎﻟﻔﻌﻞ ﺫﻟﻚ ﻳﻜﻦ ﻟﻢ ﻧﻈﺎﻡ ﻣﻠﻲﺀ ﻓﻲ ﺗﻔﺮﻁ ﻻ ﺣﺘﻰ ﺍﻟﺸﺪﻳﺪ ﺍﳊﺬﺭ ﺗﻮﺧﻲ ﻳﺠﺐ ﺍﻟﺘﺒﺮﻳﺪ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺍﻟﻀﻐﻂ ﺍﺧﺘﺒﺎﺭ ﻳﺠﺐ ﺍﻟﻨﻈﺎﻡ ﺷﺤﻦ ﺇﻋﺎﺩﺓ ﻗﺒﻞ ٧ ﺍﻟﺒﻨﺪ ﺭﺍﺟﻊ O...

Page 11: ...ﻳﺪ ﻏﺎﺯ ﻧﻘﻞ ﻋﻨﺪ ﻓﻘﻂ ﺍﳌﻨﺎﺳﺒﺔ ﺍﻟﺘﺒﺮﻳﺪ ﻏﺎﺯ ﺍﺳﺘﺮﺩﺍﺩ ﺃﺳﻄﻮﺍﻧﺎﺕ ﻟﻼﺣﺘﻔﺎﻅ ﺍﻷﺳﻄﻮﺍﻧﺎﺕ ﻣﻦ ﺍﻟﺼﺤﻴﺢ ﺍﻟﻌﺪﺩ ﺗﻮﻓﺮ ﻣﻦ ﺗﺄﻛﺪ ﺍﻹﺟﻤﺎﻟﻴﺔ ﺍﻟﻨﻈﺎﻡ ﺑﺸﺤﻨﺔ ﻣﺨﺼﺼﺔ ﺍﺳﺘﺨﺪﺍﻣﻬﺎ ﺳﻴﺘﻢ ﺍﻟﺘﻲ ﺍﻷﺳﻄﻮﺍﻧﺎﺕ ﺟﻤﻴﻊ ﺍﻷﺳﻄﻮﺍﻧﺎﺕ ﺃﻱ ﺍﻟﺘﺒﺮﻳﺪ ﻟﻐﺎﺯ ﻌﻠﻤﺔ ﹸ ﻭﻣ ﺍﳌﺴﺘﻌﺎﺩ ﺍﻟﺘﺒﺮﻳﺪ ﻟﻐﺎﺯ ﺍﻟﺘﺒﺮﻳﺪ ﻏﺎﺯ ﻻﺳﺘﻌﺎﺩﺓ ﺍﳋﺎﺻﺔ ﺗﻨﻔﻴﺲ ﺻﻤﺎﻡ ﻣﻊ ﻛﺎﻣﻠﺔ ﺍﻷﺳﻄﻮﺍﻧﺎﺕ ﺗﻜﻮﻥ ﺃﻥ ﻳﺠﺐ ﻋﻤﻞ ﺣﺎﻟﺔ ﻓﻲ ﺑﻪ ﺍﳌﺮﺗﺒﻄﺔ ﺍﻹﻏﻼﻕ ﻭﺻﻤﺎﻣﺎﺕ ﺍﻟﻀﻐﻂ ﺟﻴﺪﺓ ﻗﺒﻞ ﺗﺒﺮﻳﺪﻫﺎ ﺃﻣﻜﻦ ﻭﺇﺫﺍ ﺍﻻﺳﺘﺮﺩﺍﺩ ﺃﺳﻄﻮﺍﻧﺎﺕ ﺗﻔﺮﻳﻎ ﻳﺘﻢ ﺍﻻﺳﺘﻌﺎﺩﺓ ﺣﺪ...

Page 12: ... ﺩﺭﺟﺔ ﺇﻟﻰ ﻟﻠﻮﺻﻮﻝ JET STREAM 2 C 4 F ﺳﺎﻋﺔ ﺍﻷﻗﺼﻰ ﺍﳊﺪ ﺍﳊﺮﺍﺭﺓ ﺩﺭﺟﺔ ﺿﺒﻂ JETSTREAM ﺗﺒﺮﻳﺪ ﺳﺮﻋﺔ ﻟﺰﻳﺎﺩﺓ ﺍﳌﺮﻭﺣﺔ ﻭﺳﺮﻋﺔ ﺍﳊﺮﺍﺭﺓ ﺩﺭﺟﺔ ﺿﺒﻂ ﻓﻲ ﺍﻟﻮﺣﺪﺓ ﺗﺘﺤﻜﻢ ﺍﻟﻐﺮﻓﺔ ﺩﺭﺟﺔ ﺇﻋﺪﺍﺩ ﺁﺧﺮ ﺍﻟﻐﺮﻓﺔ ﺣﺮﺍﺭﺓ ﺩﺭﺟﺔ ﺗﺘﺒﻊ ﺗﻘﺪﻳﺮ ﺃﻗﺼﻰ ﻋﻠﻰ ﻭﺍﺣﺪﺓ ﺳﺎﻋﺔ ﺑﻌﺪ ﺿﺒﻂ ﰎ ﺣﺮﺍﺭﺓ ﺳﺮﻋﺔ ﲢﺪﻳﺪ ﻭﺳﻴﺆﺩﻱ ﺍﻟﻔﺎﺋﻘﺔ ﺍﻟﺴﺮﻋﺔ ﻭﺿﻊ ﻋﻠﻰ ﺍﳌﺮﻭﺣﺔ ﺳﺮﻋﺔ ﺗﺜﺒﻴﺖ ﻳﺘﻢ JETSTREAM ﺗﺸﻐﻴﻞ ﺇﻟﻐﺎﺀ ﺇﻟﻰ ﺍﳌﺮﻭﺣﺔ ﻣﻊ ﺍﻟﻮﺣﺪﺓ ﺳﻴﺸﻐﻞ JET STREAM ﻋﻠﻰ ﺍﻟﻀﻐﻂ ﺍﻟﻮﺣﺪﺓ ﺗﺸﻐﻴﻞ ﺇﻳﻘﺎﻑ ﺃﺛﻨﺎﺀ JETSTREAM ﻭﺿﻊ ﺗﺸ...

Page 13: ... ﺍﻟﻮﺣﺪﺓ OFF ﺗﺸﻐﻴﻞ ﺇﻳﻘﺎﻑ ﺃﻭ ON ﻟﺘﺸﻐﻴﻞ ﺍﻟﻨﻮﻡ ﺃﺛﻨﺎﺀ ﺑﺎﻟﺮﺍﺣﺔ ﺍﻟﺸﻌﻮﺭ ﻟﺰﻳﺎﺩﺓ SLEEP CANCEL ﺍﻟﻮﺿﻊ ﺗﻨﺸﻴﻂ ﻓﺘﺮﺓ ﺃﺛﻨﺎﺀ ﺎ ﹰ ﺗﻠﻘﺎﺋﻴ ﺍﻟﻨﻮﻡ ﳕﻂ ﻋﻠﻰ ﺍﳊﺮﺍﺭﺓ ﺩﺭﺟﺔ ﺑﻀﺒﻂ ﺗﻘﻮﻡ ﺇﺫ ﺍﻟﻨﻮﻡ ﺃﺛﻨﺎﺀ ﻣﺮﻳﺤﺔ ﺑﻴﺌﺔ ﺍﻟﻄﺮﻳﻘﺔ ﺑﻬﺬﻩ ﺍﻟﺘﺸﻐﻴﻞ ﳝﻨﺤﻚ ﺎ ﹰ ﻣﻌﺘﻤ ﺍﳌﺆﺷﺮ ﺳﻄﻮﻉ ﻛﺎﻥ ﺇﺫﺍ ﺍﻟﻮﺿﻊ ﻫﺬﺍ ﻳﺴﺘﺨﺪﻡ ﻻ ﻫﺬﺍ ﺍﻟﺘﺸﻐﻴﻞ ﻭﺿﻊ ﺗﻨﺸﻴﻂ ﺃﺛﻨﺎﺀ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺍﻟﻮﺣﺪﺓ ﻣﺆﺷﺮ ﺳﻴﻌﺘﻢ ﺳﺎﻋﺎﺕ ٩ ﺃﻭ ٨ ﺃﻭ ٧ ﺃﻭ ٦ ﺃﻭ ٥ ﺃﻭ ٤ ﺃﻭ ٣ ﺃﻭ ﺳﺎﻋﺘﺎﻥ ﺃﻭ ﺳﺎﻋﺔ ﺃﻭ ﺳﺎﻋﺔ ٠ ٥ ﳌﺪﺓ ﺗﻨﺸﻴﻂ ﲟﺆﻗﺖ ﺎ ﹰ ﺑ ﻣﺼﺤﻮ...

Page 14: ...ﺻﻰ ﺍﳊﺮﺍﺭﺓ ﺩﺭﺟﺔ ﻧﻄﺎﻕ ﻓﻲ ﺍﻟﻮﺣﺪﺓ ﺗﺸﻐﻴﻞ ﻋﻨﺪ ﺍﻟﻄﺎﻗﺔ ﺗﻮﻓﻴﺮ ﳝﻜﻨﻚ ﻓﻬﺮﻧﻬﺎﻳﺖ ﺩﺭﺟﺔ ٨٢ ﺇﻟﻰ ﻓﻬﺮﻧﻬﺎﻳﺖ ﺩﺭﺟﺔ ٧٩ ﻣﺌﻮﻳﺔ ﺩﺭﺟﺔ ٢٨ ﺇﻟﻰ ﻣﺌﻮﻳﺔ ﺩﺭﺟﺔ ٢٦ ﺍﻟﺘﺒﺮﻳﺪ COOL ﺍﻟﻬﻮﺍﺀ ﺗﺪﻓﻖ ﺍﲡﺎﻩ ﺍﳉﻔﺎﻑ ﺍﻟﺘﺒﺮﻳﺪ DRY COOL ﻭﺿﻊ ﻓﻲ ﺍﻟﻮﺳﻂ ﻣﻮﺿﻊ ﺇﻋﺪﺍﺩ ﻓﻲ ﺍﻷﻓﻘﻴﺔ ﺍﻟﻠﻮﺣﺔ ﺗﺜﺒﻴﺖ ﻳﺘﻢ ﺎ ﹰ ﺗﻠﻘﺎﺋﻴ ﻭﻷﺳﻔﻞ ﻷﻋﻠﻰ ﺍﻷﻓﻘﻴﺔ ﺍﻟﻠﻮﺣﺔ ﺗﺘﺄﺭﺟﺢ ﺍﶈﺪﺩﺓ ﺍﳊﺮﺍﺭﺓ ﺩﺭﺟﺔ ﺇﻟﻰ ﺍﻟﻮﺻﻮﻝ ﲟﺠﺮﺩ ﺍﳉﻔﺎﻑ ﺍﻟﺘﺒﺮﻳﺪ DRY COOL ﻭﺿﻊ ﻓﻲ ﺎ ﹰ ﺗﻠﻘﺎﺋﻴ ﻭﻷﺳﻔﻞ ﻷﻋﻠﻰ ﺍﻷﻓﻘﻴﺔ ﺍﻟﻠﻮﺣﺔ ﺗﺘﺄﺭﺟﺢ ﺍﻟﺘﻠﻘﺎﺋﻲ ﺍﻟﺘﺸﻐﻴﻞ ﺇ...

Page 15: ...ﻬﺮﻧﻬﺎﻳﺖ ﺩﺭﺟﺔ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺍﻟﻮﺣﺪﺓ ﺍﻟﻬﻮﺍﺀ ﻣﺮﺷﺢ ﺍﺳﺒﻮﻋﲔ ﻛﻞ ﻣﺮﺓ ﺑﻨﻌﻮﻣﺔ ﺑﺎﳌﺎﺀ ﺍﳌﺮﺷﺤﺎﺕ ﺍﺷﻄﻒ ﺍﻏﺴﻞ ﺍﻟﺴﻄﺢ ﺇﺗﻼﻑ ﻟﺘﺠﻨﺐ ﺃﺷﻌﺔ ﺃﻭ ﺍﻟﻨﺎﺭ ﻋﻦ ﺍ ﹰ ﺪ ﺑﻌﻴ ﺍﻟﻈﻞ ﻓﻲ ﺍ ﹰ ﺪ ﺟﻴ ﺍﳌﺮﺷﺤﺎﺕ ﺟﻔﻒ ﺍﳌﺒﺎﺷﺮﺓ ﺍﻟﺸﻤﺲ ﺗﺎﻟﻔﺔ ﻣﺮﺷﺤﺎﺕ ﺃﻱ ﺍﺳﺘﺒﺪﻝ ﺍﻟﻬﻮﺍﺀ ﻣﺮﺷﺢ ﺃﺯﻝ ﺍﻟﻬﻮﺍﺀ ﻣﺮﺷﺢ ﺿﻊ ﺍﻟﻮﺣﺪﺓ ﻣﻦ ﺃﺯﻝ ﺍﳌﻜﻴﻒ ﺍﻟﻰ ﺍﳌﺮﺷﺢ ﺍﺩﺧﻞ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺍﻟﻮﺣﺪﺓ ﻧﺎﻋﻤﺔ ﻗﻤﺎﺵ ﺑﻘﻄﻌﺔ ﺑﺮﻓﻖ ﺍﻟﻮﺣﺪﺓ ﺍﻣﺴﺢ ﻭﺟﺎﻓﺔ ﺩﻭﺭﻱ ﺑﺸﻜﻞ ﻭﺍﳌﺮﺍﻭﺡ ﺍﳌﻠﻔﺎﺕ ﺗﻨﻈﻴﻒ ﻳﺠﺐ ﻣﻌﺘﻤﺪ ﻭﻛﻴﻞ ﺑﻮﺍﺳﻄﺔ ﺍﳋﺎﺭﺟﻴﺔ ﺍﻟﻮﺣﺪﺓ ﺑﺎﻟﻮﺣﺪﺓ ﺍﶈﻴﻂ ﺍ...

Page 16: ...ﺃﻭ ﺍﳌﺎﺀ ﻳﻨﺒﻌﺚ ﻭﻗﺪ ﺍﻟﺒﺎﺭﺩﺓ ﺍﻷﻧﺎﺑﻴﺐ ﻋﻠﻰ ﺍﻟﺘﻜﺜﻴﻒ ﻳﺤﺪﺙ ﺍﻟﺘﺒﺮﻳﺪ ﻋﻤﻠﻴﺔ ﺃﺛﻨﺎﺀ ﺍﳋﺎﺭﺟﻴﺔ ﺍﻟﻮﺣﺪﺓ ﻣﻦ ﺍﳌﻜﺜﻒ ﺍﳌﺎﺀ ﻳﺘﺴﺎﻗﻂ ﺍﻟﺒﻼﺳﺘﻴﻚ ﺍﻷﺟﺰﺍﺀ ﺑﻌﺾ ﺃﻟﻮﺍﻥ ﺗﻐﻴﺮ ﺍﻟﺒﻼﺳﺘﻴﻜﻴﺔ ﺍﻷﺟﺰﺍﺀ ﻓﻲ ﺍﳌﺴﺘﺨﺪﻣﺔ ﺍﳌﻮﺍﺩ ﻷﻧﻮﺍﻉ ﺍﻟﻠﻮﻥ ﺗﻐﻴﺮ ﻳﺨﻀﻊ ﻓﻮﻕ ﺍﻷﺷﻌﺔ ﺿﻮﺀ ﺃﻭ ﺍﻟﺸﻤﺲ ﺿﻮﺀ ﺃﻭ ﻟﻠﺤﺮﺍﺭﺓ ﺗﻌﺮﺿﻬﺎ ﻋﻨﺪ ﺗﺘﺴﺎﺭﻉ ﺍﻟﺒﻴﺌﻴﺔ ﺍﻟﻌﻮﺍﻣﻞ ﺃﻭ ﺍﻟﺒﻨﻔﺴﺠﻴﺔ ﻣﻦ ﻣﺒﻜﺮﺓ ﻣﺮﺣﻠﺔ ﺧﻼﻝ ﺍﳋﺎﺭﺟﻴﺔ ﺍﻟﻮﺣﺪﺓ ﻣﻦ ﻋﺎﻟﻲ ﺻﻮﺕ ﺍﻟﻨﻔﺎﺙ ﺗﻴﺎﺭ JETSTREAM ﺗﺸﻐﻴﻞ ﻋﻤﻠﻴﺔ ﻣﻦ ﻣﺒﻜﺮﺓ ﻣﺮﺣﻠﺔ ﺧﻼﻝ ﺍﻟﺘﺒﺮﻳﺪ ﺃﺩﺍﺀ ﻟﺘﻌﺰﻳﺰ ...

Page 17: ...ﺎﺭ ﺍﻟﻮﺣﺪﺓ ﻓﻲ AUTO OFF ON ﺍﺳﺘﺨﺪﻡ ﻭﻣﺨﺮﺝ ﻣﺪﺧﻞ ﻓﺘﺤﺎﺕ ﺑﻴﻦ ﺍﻟﺘﺎﻟﻴﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺩﺭﺟﺔ ﻓﻲ ﺍﺧﺘﻼﻑ ﻫﻨﺎﻙ ﻳﻜﻮﻥ ﺃﻥ ﺍﻟﻄﺒﻴﻌﻲ ﻣﻦ ﺍﻟﺘﺸﻐﻴﻞ ﻣﻦ ﺩﻗﻴﻘﺔ ١٥ ﺑﻌﺪ ﺃﻋﻼﻩ ﺣﺪﺙ ﺍﻟﻬﻮﺍﺀ ﻓﻬﺮﻧﻬﺎﻳﺖ ﺩﺭﺟﺔ ١٤ ٤ ﻣﺌﻮﻳﺔ ﺩﺭﺟﺔ ٨ ﺍﻟﺘﺒﺮﻳﺪ COOL ﺃﻃﻮﻝ ﻟﻔﺘﺮﺓ ﺍﻟﻮﺣﺪﺍﺕ ﺍﺳﺘﺨﺪﺍﻡ ﻳﺘﻢ ﻟﻦ ﺍﻟﻜﻬﺮﺑﺎﺀ ﻗﺎﺑﺲ ﻣﻦ ﺍﻟﻮﺣﺪﺓ ﺍﻓﺼﻞ ﺛﻢ ﺍﻟﻮﺣﺪﺓ ﺗﺸﻐﻴﻞ ﺑﺈﻳﻘﺎﻑ ﻗﻢ ﺑﻌﺪ ﻋﻦ ﺍﻟﺘﺤﻜﻢ ﺟﻬﺎﺯ ﻣﻦ ﺍﻟﺒﻄﺎﺭﻳﺎﺕ ﺑﺈﺯﺍﻟﺔ ﻗﻢ ﻗﺒﻠﻚ ﻣﻦ ﺍﺻﻼﺣﻬﺎ ﻻﳝﻜﻦ ﺍﻟﺘﻲ ﺍﻻﻋﻄﺎﻝ ﺍﻟﺘﺎﻟﻴﺔ ﺍﳊﺎﻻﺕ ﻓﻲ ﻣﻌﺘﻤﺪ ﻭﻛﻴﻞ ﺍﺳﺘﺸﺮ ﺛﻢ ﺍﻟﻜﻬﺮﺑﺎﺀ...

Page 18: ...hen press to set the time Press for approximately 5 seconds to show the time as 12 hour am pm or 24 hour 2 Press SET to confirm Use the remote control within 8 m from the remote control receiver on the indoor unit 8 AIR CONDITIONER ON OFF SET TIMER CANCEL OFF ON TEMP OFF ON MODE SLEEP AIR SWING JET STREAM FAN SPEED QUIET AIR CONDITIONER ON OFF TIMER CANCEL SLEEP AIR SWING JET STREAM FAN SPEED QUIE...

Page 19: ...rom the remote control display 3 Press TEMP UP TEMP DOWN to select the desired temperature TEMP Up Down Selection range 16 C 30 C 60 F 86 F Press for approximately 10 seconds to show the temperature as C or F Thank you for purchasing Panasonic Air Conditioner The illustrations in this manual are for explanation purposes only and may differ from the actual unit They are subject to change without no...

Page 20: ...nstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc Do not use means to accelerate the defrosting process or to clean other than those recommended by manufacturer Any unfit meth...

Page 21: ...ng activity CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for preservation of precise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation Do not ...

Page 22: ...eal the opening by pinching taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use of flammable refrigerants and as recommended by the manufacturer Any personnel conducting an operation servicing or maintenance on a system or associated parts of the equipment should be trained and c...

Page 23: ...tions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised and maintained by a trained and certified service personnel who is employed by the person user or party responsible Ensure the actual refrigerant charge is in accordance with the room size within which the refr...

Page 24: ...ternally into the atmosphere 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance The following checks shall be applied to installations u...

Page 25: ...here from a leak 5 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans 6 Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in ...

Page 26: ... minimize the amount of refrigerant contained in them Cylinders shall be kept in an appropriate position according to the instructions Ensure that the refrigerating system is earthed prior to charging the system with refrigerant Label the system when charging is complete if not already Extreme care shall be taken not to over fill the refrigerating system Prior to recharging the system it shall be ...

Page 27: ...nsure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the recovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in good working order Recovery cylinders are evacuated and if p...

Page 28: ... QUIET To reach temperature quickly JET STREAM 2 C 4 F Max 1 hour Set temperature JETSTREAM The unit controls set temperature and fan speed to accelerate room cooling After max 1 hours the set temperature follows the last set temperature setting Fan Speed is fixed at Super High Fan speed selection will cancel JETSTREAM Operation During unit is off pressing JET STREAM will turn on the unit with JET...

Page 29: ...d will repeat daily when timer has been set For clock setting refer to Quick Guide To turn ON or OFF the unit at a preset time To maximise comfort while sleeping SLEEP CANCEL This operation provides you with a comfortable environment while sleeping It will automatically adjust the sleep pattern temperature during the activation period The indoor unit indicator will dim when this operation is activ...

Page 30: ...en operating the unit within the recommended temperature range COOL 26 C 28 C 79 F 82 F Air flow direction In COOL DRY mode The horizontal flap is fixed at middle position setting Once the temperature is achieved the horizontal flap swings up down automatically In COOL DRY mode The horizontal flap swings up down automatically Auto restart control When power is resumed after a power failure the ope...

Page 31: ... Once every 2 weeks Wash rinse the filters gently with water to avoid damaging the surface Dry the filters thoroughly under a shade away from fire or direct sunlight Replace any damaged filters Remove air filter Attach air filter Remove from the unit Insert into the unit Indoor unit Wipe the unit gently with a soft and dry cloth The coils and fans should be cleaned periodically by an authorised de...

Page 32: ...uring cooling operation condensation occurs on cold pipes and the condensed water may drip from the outdoor unit Discoloration of some plastic parts Discoloration is subjected to the types of materials used in plastic parts It is accelerated when exposed to heat sun light UV light or environmental factors Louder noise at outdoor unit during early operation of JETSTREAM The fan rotate at higher spe...

Page 33: ...emote control is missing or a malfunction has occurred above After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14 4 F The units will be not used for an extended period Turn off the power supply and unplug the unit Remove the batteries from the remote control NON SERVICEABLE CRITERIAS TURN OFF THE POWER SUPPLY AND...

Page 34: ...ﻻﺧﺮﻳﻦ ﺍﻟﺮﻣﺰﻳﻦ ﻣﺜﺎﻝ ﺍﻟﺒﻄﺎﺭﻳﺔ ﺭﻣﺰ ﻻﺣﻆ ﺍﻻﺩﺍﺭﻱ ﺍﻻﻣﺮ ﻣﺘﻄﻠﺒﺎﺕ ﻣﻊ ﻳﻨﻄﺒﻖ ﻓﺎﻧﻪ ﺍﳊﺎﻟﺔ ﻫﺬﻩ ﻓﻲ ﺍﻭ ﻛﻴﻤﻴﺎﻭﻱ ﺭﻣﺰ ﻣﻊ ﻳﺴﺘﻌﻤﻞ ﻗﺪ ﺍﻟﺮﻣﺰ ﻫﺬﺍ ﺍﻥ ﺍﻟﺪﺍﺧﻠﻪ ﺍﻟﻜﻴﻤﻴﺎﻭﻳﺔ ﺍﳌﻮﺍﺩ ﺣﻮﻝ ﲢﺬﻳﺮ ﻏﺎﺯ ﻳﺴﺘﺨﺪﻡ ﺍﳉﻬﺎﺯ ﻫﺬﺍ ﺃﻥ ﺍﻟﺮﻣﺰ ﻫﺬﺍ ﻳﺪﻝ ﻏﺎﺯ ﺗﺴﺮﻳﺐ ﰎ ﺇﺫﺍ ﻟﻼﺷﺘﻌﺎﻝ ﻗﺎﺑﻠﺔ ﺗﺒﺮﻳﺪ ﻓﻬﻨﺎﻙ ﺧﺎﺭﺟﻲ ﺇﺷﻌﺎﻝ ﻣﺼﺪﺭ ﻣﻊ ﺍﻟﺘﺒﺮﻳﺪ ﻟﻼﺷﺘﻌﺎﻝ ﺍﺣﺘﻤﺎﻝ ﺗﻌﻠﻴﻤﺎﺕ ﻗﺮﺍﺀﺓ ﻳﺠﺐ ﺃﻧﻪ ﺍﻟﺮﻣﺰ ﻫﺬﺍ ﻳﺪﻝ ﺑﻌﻨﺎﻳﺔ ﺍﻟﺘﺸﻐﻴﻞ ﻣﻮﻇﻒ ﻳﻘﻮﻡ ﺍﻥ ﻳﺠﺐ ﺃﻧﻪ ﺍﻟﺮﻣﺰ ﻫﺬﺍ ﻳﺪﻝ ﺇﻟﻰ ﺑﺎﻟﺮﺟﻮﻉ ﺍﳉﻬﺎﺯ ﻫﺬﺍ ﻣﻊ ﺑﺎﻟﺘﻌﺎﻣﻞ...

Page 35: ...bination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved WARNING This symbol shows that this equipment uses a flammable refrigerant If the refrigerant is leaked together with an external ignition source there is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows t...

Page 36: ...Printed in Malaysia ACXF55 31540 FS0122 0 Panasonic Corporation 1006 Oaza Kadoma Kadoma City Osaka 571 8501 Japan Website http www panasonic com Panasonic Corporation 2022 ...

Reviews: