background image

English

7

How to use

To adjust airflow direction

(Remote control display)

• Keeps the room ventilated.
• If AUTO air swing is set, the flaps swings 
  left/right and up/down automatically.
• The horizontal and vertical flap are fixed at the
  predetermined position.
• Do not adjust the flap by hand.

(Vertical)

(Horizontal)

To set the timer

To turn ON and OFF the unit at a preset times. 

1

2

3

1

Select ON or OFF 
timer

Example: 
OFF at 22:00

• Each time pressed:

Cancel

2

Set the time

3

Confirm

TIMER

• To cancel ON or OFF timer, press 

 or 

 then press 

.

• If timer is cancelled manually or due to power 

failure, you can restore the timer again by 
pressing 

 or 

 then press 

.

• The nearest timer setting will be displayed and 

will activate in sequence.

• When ON Timer is set, the unit may start 

earlier (up to 15 minutes) before the actual 
set time in order to achieve the desired 
temperature on time.

• Timer operation is based on the clock set in 

the remote control and repeats daily once set. 
For clock setting, please refer to Quick guide.

Auto Restart Control

• If power is resumed after a power failure, the 

operation will restart automatically after a period 
of time with previous operation mode and airflow 
direction.

• This control is not applicable when TIMER is set.

To select fan speed 

(Remote control display)

(Low)

(Medium)

(High)

AUTO

FAN

• For AUTO, the indoor fan speed is automatically
  adjusted according to the operation mode. 

Operation conditions

Use this air conditioner under the following
temperature range.
DBT  : Dry bulb temperature
WBT : Wet bulb temperature

50

30

• nanoe-G starts automatically when the unit is
  turned on with          .

• Can be activated even when the unit is turned
  off. In this condition, the unit will operate as a fan
  with AUTO fan speed and louver swing.

nanoe-G
PURIFIER

nanoe-G

ACXF55-2242̲OL.ai   7   1/28/2020   12:46:34 PM

ACXF55-2242̲OL.ai   7   1/28/2020   12:46:34 PM

Summary of Contents for CS-XS12VKYF Series

Page 1: ...nk you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference SLEEP SLEEP POWERFUL POWERFUL nanoe G nanoe G PURIFIER PURIFIER ACXF55 2242 OL ai 1 1 28 2020 12 46 28 PM ACXF55 2242 OL ai 1 1 28 2020 12 46 28 PM ...

Page 2: ...ACXF55 2242 OL ai 2 1 28 2020 12 46 32 PM ACXF55 2242 OL ai 2 1 28 2020 12 46 32 PM ...

Page 3: ... 2 C lower than room temperature Use remote control within 7 m from the remote control receiver of the indoor unit Default set temperature is 24 C in COOL mode as per country guidelines Safety precautions 4 5 How to use 6 7 Cleaning instructions 8 Troubleshooting 9 FAN DRY 7m 1 3 2 BEE Regulation 10 Information 11 POWERFUL QUIET nanoe G 2 1 3 ACXF55 2242 OL ai 3 1 28 2020 12 46 32 PM ACXF55 2242 O...

Page 4: ...stall remove and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc Do not install the unit in a potentially explosive or flammable atmosphere Failure to do so could result ...

Page 5: ... CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for preservation of precise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation Do not expose plan...

Page 6: ...s power reset To maximise comfort while sleeping This operation provides you with a comfortable environment while sleeping by gradually increase the set temperature 1 C after every 3 hours operation The unit is turned off after 8 hours Can be cancelled by pressing the respective button again SLEEP POWERFUL To switch between POWERFUL and QUIET mode POWERFUL To reach set temperature quickly SLEEP PO...

Page 7: ...to achieve the desired temperature on time Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Quick guide Auto Restart Control If power is resumed after a power failure the operation will restart automatically after a period of time with previous operation mode and airflow direction This control is not applicable when TIMER ...

Page 8: ...f the unit cleaning has to be carried out at regular intervals A dirty unit may cause malfunction Please consult authorised dealer Switch off the power supply and unplug before cleaning Do not touch the aluminium fin sharp parts may cause injury Do not use benzine thinner or scouring powder Use only soap pH 7 or neutral household detergent Do not use water hotter than 40 C Indoor unit Wipe the uni...

Page 9: ...tons are not functioning properly The unit stops and the TIMER indicator blinks Use remote control to retrieve error code Press for 5 seconds Press for 5 seconds to quit checking Press until you hear 4 beep sound then write down the error code Turn the unit off and reveal the error code to authorised dealer 2 1 3 4 operation but if problem persist please consult authorised dealer with error code F...

Page 10: ...sts 60g shall be released to follow the rated refrigerant amount mentioned in nameplate Open the Front Panel by lifting Intake Grille Follow the below Instructions 4 Air Swing Horizontal Airflow Set vane position to be straight For applicable Model 5 Fan speed Maximum 1 2 1 2 For Half Load QUIET CLEAN 1 2 1 2 Indication for Half load Indication for Full load POWER TIMER nanoe G PURIFIER SLEEP POWE...

Page 11: ...p www panasonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental breakag...

Page 12: ...F55 22420 AB FT0918 0 Printed in India Panasonic Corporation Website http www panasonic com Panasonic Corporation 2019 ACXF55 2242 OL ai 12 1 28 2020 12 46 36 PM ACXF55 2242 OL ai 12 1 28 2020 12 46 36 PM ...