Panasonic CS-XE12CKR Operating Instructions Manual Download Page 6

TROUBLESHOOTING

OK?

1

2

3

4

5

6

7

8

1

2

3

4

No problem

In case of...

Abnormal noise during operation

Water/foreign particles have entered the Remote Control

Water leak from Indoor unit

Switches/buttons do not operate properly

Circuit breaker switches off frequently

Power plug/cord become unnaturally warm

• «

TIMER

»

 flashes

!

No Operation

3

Circuit breaker tripped?

3

Power plug OK?

3

TIMER used correctly?

Remote control/display doesn

t work

3

Batteries empty?

3

Batteries correctly inserted? See page 56

Noise too loud

3

Installation work slanted?

3

Front grille/panel closed properly?

Cooling/heating efficiency low

3

Temperature set correctly?

3

Windows/doors closed?

3

Filters cleaned/replaced?

3

Outdoor unit obstructed?

3

Intake/outlet ventilators obstructed?

It sounds like water flowing...

3

Caused by refrigerant flow inside

Mist seems to emerge from the indoor unit

3

Condensation effect due to cooling

Outdoor unit emits water/steam

3

Condensed moisture due to cooling

Delayed air discharging

3

At COOL, SOFT DRY (Auto Fan Speed): Prevent odours
from blowing out

3

At HEAT (POWER LED flashes): Prevent cold air from
blowing out

Function stops suddenly

3

At COOL, SOFT DRY (Auto Fan Speed): Function
interruptions to the internal temp. measurement

3

At HEAT (POWER LED flashes): Iced up outer device is
defrosted (approx. 10min.)

Smell during oxygen operation

3

Oxygen brought in from the outside air may contain odour.
Remove source of odour around the outdoor unit.

Soft splashing sound from indoor unit during oxygen operation

3

Sound emitted by high humidity airflow from oxygen tube

Slight increase in sound level from outdoor unit

3

Sound increased cause by oxygen operation

1.

press

CHECK

RESET

CHECK

CLOCK

FA

OFF

CANCE

ON

SE

1

2

TIMER

5 sec.

2.

search code

if 4x beep

=Code

(H23/H26/H27/H28)

*Emergency operation (limited function)

TURN OFF / UNPLUG

CALL authorized distributor

*1. Press MODE - 2. Select COOL/HEAT - 3. Press OFF/ON

57

CS-XE9CKR CU-XE9CKR / CS-XE12CKR CU-XE12CKR

Summary of Contents for CS-XE12CKR

Page 1: ... under front panel see page 4 Indicator Auto operation button Cooling Heating Dehumidifying Air Circulation 1 3 Remote Control 1 Direction louver 0 1 0 m Fluorescent lights may interfere with signal transmission see page see page Memory reset 1 2 3 Under front panel Open Ioniz er DO NOT TOUCH Switch OFF ON of the device Activate Select air flow direction Select Fan Speed Set CLOCK Set TEMPERATURE ...

Page 2: ...AT min 1 6 C max 30 C TEMP AUTO ON OFF HEAT FAN AUTO AUTO Choose the right temperature to be comfortably cool Cooling COOL min 1 6 C max 30 C TEMP AUTO ON OFF COOL FAN AUTO AUTO V ery gentle cooling and dehumidifying operation Dehumidifying DRY min 1 6 C max 30 C TEMP AUTO ON OFF DRY FAN AUTO AUTO COOL DRY HEAT Recommended 20 24 C 26 28 C Recommended Room temperature 1 2 C Switch off Fan operation...

Page 3: ...de quiet operation Air flow sound Air flow sound will reduce during operation ON OF F Activate Deactivate Produce negative ion for fresh air ON Provide negative ion during operation OF F Provide negative ion with FAN operation Air conditioner If Blinking press twice Still Blinking Call Service OXYGEN Operation ON OF F Activate Deactivate ON Enriches oxygen content during operation OF F Enriches ox...

Page 4: ...ow HELPFUL INFORMATION CARE CLEANING Front panel Decorative Panel Purifying filter Thunder Lightning Built in surge protection BUT UNPLUG in case of very strong lightning MODE Filters 3 Release holder from rear side Max 20 Dry Cloth AUTO 10 COOL 1 C HEAT 2 C Use TIMER QUIET Remove Reinstall Wash Dry Beware of dropping Insert decorative panel Part No CZ SF70P Vacuum refresh Remove 3 4 every 2 weeks...

Page 5: ...Plug breaker 2 3 h For extended non operation dry internal parts START Unplug Remove batteries OFF Remove AIR filters Place PURIFYING filter Place AIR filters CLOSE front panel Plug in Call Service ервиз Καλέστε τον αντιπρ σωπο вы зовите сервис 15 Min Open remove Rechargeable Insert batteries close Check 1 Use Year Press Set time Set current time immediately Confirm Check 1 Fans obstructed OK 2 Ba...

Page 6: ...n effect due to cooling Outdoor unit emits water steam 3 Condensed moisture due to cooling Delayed air discharging 3 At COOL SOFT DRY Auto Fan Speed Prevent odours from blowing out 3 At HEAT POWER LED flashes Prevent cold air from blowing out Function stops suddenly 3 At COOL SOFT DRY Auto Fan Speed Function interruptions to the internal temp measurement 3 At HEAT POWER LED flashes Iced up outer d...

Page 7: ...objects into the unit especially dangerous for children Unused for a long time OFF unplug NEVER install remove or reinstall yourself NOT in potentially explosive atmosphere Australia AS Standard The appliance is not intended for use by young children or infirm person without supervision Young children should be supervised to ensure that they do not play with the appliance United Kingdom GB Standar...

Page 8: ...ark AUTO min max min max 53 Automatic Operation indoor temp is gauged to select the optimum mode 54 Ionizer Mode produce negative ion for fresh air 54 Oxygen Mode enriches oxygen content in fresh air 54 Quiet Mode to provide quiet operation 55 Auto Restart Control after power failure restart automatically when power resume 55 Removable Front Panel for quick and easy cleaning washable 55 Decorative...

Reviews: