13.8 Random Auto Restart Control
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes. There are 10 patterns to be selected randomly after power supply resumes.
This control is not applicable during OFF/ON Timer setting.
This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.
Enable or disable selection
iCOMFiAUTO-XHEATCOOLDRYFAN
F
SHOWER
DIRECT
AM
PM
AM
ON
OFF
PM
Transmit
“Enable or Disable” code
Normal display mode
Control
Disable
Control
Enable
Press
SW to enter customer zone &
Press
SW’s to choose function 10
SET
13.9 Indication Panel
LED
POWER
TIMER
nanoe-G
DUST SENSOR
Color
White
White
White
White / Red
Light ON
Operation ON
Timer Setting ON
nanoe-G
Mode ON
DUST SENSOR
Mode ON
Light OFF
Operation OFF Timer Setting OFF
nanoe-G
Mode OFF
DUST SENSOR
Mode OFF
Note:
If POWER LED blinks, the possible operation of the unit is ON timer sampling.
If TIMER LED blinks, there is an abnormal operation occurs.
13.10 nanoe-G Operation
This operation provides clean air by producing great amount of negative ions and distribute through the
discharge airflow to capture or deactivate molds, bacteria or viruses.
nanoe-G operation start condition
o
During unit running at any operation mode, if nanoe-G operation is activated, combination operation
(operation mode + nanoe-G operation) starts.
o
During unit is OFF, if nanoe-G operation is activated, nanoe-G individual operation starts.
nanoe-G operation stop condition
o
When OFF/ON button is pressed to stop the operation.
o
When nanoe-G button is pressed.
o
When OFF Timer activates.
nanoe-G operation pause condition
o
When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe-G operation resume after
indoor fan restarts.
o
When indoor intake temperature ≥ 40°C. nanoe-G operation resume after indoor intake temperature < 40°C
continuously for 30 minutes.