8.12. Powerful Mode Operation
Purpose of this operation is to be obtain the setting temperature quickly.
1. Cooling and Soft Dry Mode
•
When the Powerful Mode is set, the set temperature will be automatically decreased 3°C against the present setting
temperature. This operation automatically will be running under Super High Fan speed.
•
Vertical Airflow Direction:-
In “Manual” setting, the vane will automatically shift down 10°C lower than previous setting.
In “Auto” setting, the vane will automatically swing up and down. However the upper and down. However the upper and
lower limit will be shifted 10° downward.
2. Heating Mode
•
When the Powerful Mode is set, the set temperature will be automatically increased 3°C against the present setting
temperature.
•
The Fan Speed will shift as shown below:
•
Vertical Airflow Direction:-
In “Manual” setting, the vane will automatically shift down 5°C lower than previous setting.
In “Auto” setting, the vane will automatically shift between upper and lower limit depending on the intake air temperature as
Heating Mode, Airflow Direction Auto-Control. However the upper and lower limit will be shifted 5°C downward.
3. Powerful mode will operate for 15 minutes only.
4. Powerful Mode will stop if:
•
Power mode button is pressed again.
•
Stopped by ON / OFF switch.
•
Timer-off activates.
•
Economy mode button is pressed.
•
Sleep mode button is pressed.
•
Operating mode is changed.
35
CS-VA75KE CU-VA75KE / CS-VA95KE CU-VA95KE / CS-VA125KE CU-VA125KE
Summary of Contents for CS-VA75KE
Page 12: ...4 Dimensions 12 CS VA75KE CU VA75KE CS VA95KE CU VA95KE CS VA125KE CU VA125KE...
Page 13: ...13 CS VA75KE CU VA75KE CS VA95KE CU VA95KE CS VA125KE CU VA125KE...
Page 14: ...5 Refrigeration Cycle Diagram 14 CS VA75KE CU VA75KE CS VA95KE CU VA95KE CS VA125KE CU VA125KE...
Page 15: ...15 CS VA75KE CU VA75KE CS VA95KE CU VA95KE CS VA125KE CU VA125KE...
Page 16: ...6 Block Diagram 16 CS VA75KE CU VA75KE CS VA95KE CU VA95KE CS VA125KE CU VA125KE...
Page 92: ...15 Technical Data 92 CS VA75KE CU VA75KE CS VA95KE CU VA95KE CS VA125KE CU VA125KE...
Page 94: ...94 CS VA75KE CU VA75KE CS VA95KE CU VA95KE CS VA125KE CU VA125KE...
Page 95: ...95 CS VA75KE CU VA75KE CS VA95KE CU VA95KE CS VA125KE CU VA125KE...
Page 96: ...96 CS VA75KE CU VA75KE CS VA95KE CU VA95KE CS VA125KE CU VA125KE...
Page 107: ...107 CS VA75KE CU VA75KE CS VA95KE CU VA95KE CS VA125KE CU VA125KE...
Page 109: ...23 1 REMOTE CONTROL 109 CS VA75KE CU VA75KE CS VA95KE CU VA95KE CS VA125KE CU VA125KE...
Page 112: ...112 CS VA75KE CU VA75KE CS VA95KE CU VA95KE CS VA125KE CU VA125KE MACC Printed in Malaysia...