Panasonic CS-V9NKA Operating Instructions Manual Download Page 12

12

MILD DRY

COOLING

ORT

MODE

POWERFUL/

QUIET

TEMP

TIMER

SET

ON

1

2

3

NANOE

-G

AIR SWING

FAN SPE

ED

V18NKA, V24NKA, 

V28NKA, V18NWA

6

REMOTE CONTROL

Press the remote control’s button

1

TO TURN ON OR OFF THE UNIT

POWER

•  Please be aware of the OFF indication on the remote 

control display to prevent the unit from starting/stopping 

improperly.

2

 

TO SET TEMPERATURE

•  For cool and dry modes, the range of temperature for 

selection is 16

˚

C ~ 30

˚

C.

•  Operating the unit within the recommended temperature 

could induce energy saving.

COOL mode : 26

˚

C ~ 28

˚

C.

DRY mode : 1

˚

C ~ 2

˚

C lower than room temperature.

3

TO SELECT OPERATION MODE

AUTO mode - For your convenience

•  Unit selects the operation mode according to the room 

temperature.

•  Once auto mode is selected, the unit will operate at the 

standard setting temperature.

Room 

temperature

Operation mode

Standard setting 

temperature

23

˚

C & above

Cool

25

˚

C

Below 23

˚

C

Dry

22

˚

C

• Press 

 for “HI” to +2

˚

C or 

 for “LO” to -2

˚

C to the 

standard setting temperature.

COOL mode - To enjoy cool air

•  Use curtains to screen off sunlight and outdoor heat to 

reduce power consumption during cool mode.

DRY mode - To dehumidify the environment

•  Unit operates at low fan speed to give a gentle cooling 

operation.

4

TO SELECT FAN SPEED (3 OPTIONS)

FAN SPEED

•  For AUTO, the indoor fan speed is automatically adjusted 

according to the operation mode.

5

TO ADJUST VERTICAL AIRFLOW DIRECTION 

(5 OPTIONS)

AIR SWING

•  Keeps the room ventilated.

•  In COOL/DRY mode, if AUTO is set, the louver swing 

up/down automatically.

6

TO ADJUST AIRFLOW DIRECTION (5 OPTIONS)

AIR SWING

•  Keeps the room ventilated.

•  In COOL/DRY mode, if AUTO is set, the louver swing 

left/right and up/down automatically.

FAN SPE

ED

AIR SWI

NG

NANOE

-G

POWERFUL/

QUIET

MODE

TEMP

OFF/ON

TIMER

SET

CANCEL

ON

OFF

1

2

3

SET

CLOCK

RESET

OFF

TIMER

ON

TIMER

AUTO

COOL

DRY

FAN

SPEED

AIR

SWING

3

7

4

2

5

12

1

9

10

11

V9NKA, V12NKA, V7NWA, 

V9NKA, V12NKA, V7NWA, 

V9NWA, V12NWA

V9NWA, V12NWA

Remote 

Control display

Maximum distance: 8m

Indicator

(Green)

(Orange)

(Blue)

(Orange/ 

Green)

POWER

TIMER

NANOE-G

POWERFUL/QUIET

Remote control receiver

8

Summary of Contents for CS-V9NKA

Page 1: ...KA CS V28NKA CU V28NKA CS V7NWA CU V7NWA CS V9NWA CU V9NWA CS V12NWA CU V12NWA CS V18NWA CU V18NWA QUICK GUIDE QUICK GUIDE ENGLISH Before operating the unit read these operating instructions thoroughl...

Page 2: ...E OF CONTENTS SAFETY PRECAUTIONS 10 11 REMOTE CONTROL 12 13 INFORMATION 13 INDOOR UNIT 14 TROUBLESHOOTING 15 QUICK GUIDE BACK COVER NOTE The illustrations in this manual are for explanation purposes o...

Page 3: ...16 11 OPERATION CONDITION OPERATION CONDITION Use this air conditioner under the following temperature range Temperature C Indoor Outdoor DBT Dry bulb temperature WBT Wet bulb temperature DBT WBT DBT...

Page 4: ...4...

Page 5: ...5 Ni Cd ELCB RCD ELCB GB...

Page 6: ...P OFF ON TIMER SET CANCEL ON OFF 1 2 3 SET CLOCK RESET OFF TIMER ON TIMER AUTO COOL DRY FAN SPEED AIR SWING 3 7 4 2 5 12 1 9 10 11 V9NKA V12NKA V7NWA V9NKA V12NKA V7NWA V9NWA V12NWA V9NWA V12NWA 8 POW...

Page 7: ...noe G 8 POWERFUL QUIET POWERFUL QUIET POWERFUL QUIET QUIET POWERFUL NORMAL POWERFUL 15 QUIET 9 5 10 10 C F 11 12 NANOE G POWERFUL QUIET POWERFUL QUIET ON OFF 1 2 TIMER SET ON OFF ON OFF CANCEL 15 SET...

Page 8: ...2 2 1 1 1 2 V18NKA V24NKA V28NKA V18NWA 3 4 5 V9NKA V12NKA V7NWA V9NWA V12NWA V18NKA V24NKA V28NKA V18NWA 6 7 8 9 nanoe G 6 nanoe G POWER TIMER NANOE G POWER FUL QU IET 2 7 1 4 8 5 6 3 9 nanoe G pH7 4...

Page 9: ...9...

Page 10: ...cause leakage electric shock or fire Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product damage burst...

Page 11: ...lightning activity CAUTION CAUTION INDOOR UNIT AND OUTDOOR UNIT Do not wash the indoor unit with water benzene thinner or scouring powder to avoid damage or corrosion at the unit Do not use for preser...

Page 12: ...to 2 C to the standard setting temperature COOL mode To enjoy cool air Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode DRY mode To dehumidify the env...

Page 13: ...emical involved Pb NOTES NOTES NANOE G POWERFUL QUIET Can be activated in all modes and can be cancelled by pressing the respective button again POWERFUL QUIET Cannot be selected at the same time 7 TO...

Page 14: ...s the button to turn off 8 AIR FILTERS Air filter cleaning is required every two weeks Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under s...

Page 15: ...once set Cracking sound during operation Changes of temperature caused the expansion contraction of the unit Check the following before calling for servicing Check the following before calling for se...

Page 16: ...OL DRY Panasonic Corporation Website http panasonic net Printed in Malaysia F568375 YS1011 0 2 1 3 V18NKA V24NKA V28NKA V18NWA V9NKA V12NKA V7NWA V9NKA V12NKA V7NWA V9NWA V12NWA V9NWA V12NWA Remote Co...

Reviews: