Cooling or Soft Dry Operation
Purpose is to obtain a comfortable room temperature while
sleeping. When you press the SLEEP Mode, the following
movement will start to avoid overcooling.
•
Sleep shift operation starts, when the room temperature
reaches the setting temperature or after 1 hour of operation.
•
The setting temperature will be risen by 0.5°C at the start of
operation and by 0.5°C one hour later.
•
The airflow volume will automatically change to Lo fan
speed.
•
Sleep Mode operation time is 8 hours, the operation will be
stop after 8 hours.
•
When used together with the Timer, the Timer has priority.
8.5. Sleep Mode Auto Operation
8.6. Powerful Mode Operation
•
Purpose of this operation is to obtain the setting temperature quickly.
•
When the Powerful Mode is set, the set temperature will be automatically decreased 3°C against the present setting
temperature (Lower temperature: 16°C).
•
This operation automatically will be running under SHi Fan Speed (Cooling), SLo Fan Speed (Soft Dry).
•
Vertical Airflow Direction:-
- In “Manual” setting, the vane will automatically swing down 10° lower than previous setting.
- In “Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward.
•
Powerful Mode will operate for 15 minutes only, after that it will shift back to previous operation mode.
•
Powerful Mode will stop if:-
- Powerful mode button is pressed again.
- Stopped by ON / OFF switch.
- Timer OFF activates.
- Economy mode button is pressed.
- Sleep mode is pressed.
- Operation mode button is changed.
8.7. Economy Mode Operation
•
Purpose of this operation is to save or reduced electrical power consumption of the room air conditioner.
•
When the Economy Mode is set, the set temperature will be automatically increased 0.5°C against the preset setting
temperature (Higher temperature: 30°C).
•
This operation automatically will be running under SLo Fan Speed.
•
Vertical Airflow Direction:-
In “Manual” or “Auto” setting, the vane will automatically change to Auto Air Swing.
•
Economy Mode will stop if:-
- Economy Mode button is pressed again.
- Stopped by ON / OFF switch.
- Timer OFF activates.
- Powerful mode button is pressed.
- Auto or Manual air swing button is pressed.
- Fan Speed control button is pressed.
- Sleep Mode button is pressed ON.
- Operation Mode is changed.
31