8.3. Automatic Operation
•
Automatic operation can be set using remote control.
•
This operation starts to operate with indoor fan at SLo speed for 20 seconds to judge the intake air temperature.
•
After judged the temperature, the operation mode is determined by referring to the below standard.
•
Then, the unit start to operate at determined operation mode, until it is switched off using remote control, with the setting
temperature as shown in below table.
•
The setting temperature for all the operations can be changed one level up or one level down from the standard temperature
as shown in below table by pressing on the temperature up or temperature down button at remote control.
Operation
Hi
(Standard)
Lo
(+2°C)
(±0°C)
(-2°C)
Cooling
27°C
25°C
23°C
Soft Dry
24°C
22°C
20°C
•
The operation mode judging temperature and standard setting temperature can be increased by 2°C permanently, by open the
circuit of JX1 at indoor electronic controller.
8.4. Operation Control
(For 8.5.1 to 8.5.7 information applies only to Cooling and Soft Dry Operation)
8.4.1. Restart Control (Time Delay Safety Control)
•
When the thermo-off temperature (temperature which compressor stops to operate) is reached during:-
−
Cooling operation - the compressor stops for 3 minutes (minimum) before resume operation.
−
Soft Dry operation - the compressor stops for 6 minutes (minimum) before resume operation.
•
If the operation is stopped by the remote control, the compressor will not turn on within 3 minutes from the moment operation
stop, although the unit is turn on again within the period.
•
This phenomenon is to balance the pressure inside the refrigerant cycle.
8.4.2. 60 Seconds Forced Operation
•
Once the air conditioner is turned on, the compressor will not stop within 60 seconds in a normal operation although the intake
air temperature has reached the thermo-off temperature. However, force stop by pressing the OFF/ON operation button at the
remote control is permitted.
•
The reason for the compressor to force operate at minimum 60 seconds is to allow the refrigerant oil run in a full cycle and
return back to the outdoor unit.
18
CS-V18DKE CU-V18DKE / CS-V24DKE CU-V24DKE
Summary of Contents for CS-V18DKE
Page 11: ...4 2 Outdoor Unit 4 2 1 CU V18DKE CU V24DKE 11 CS V18DKE CU V18DKE CS V24DKE CU V24DKE ...
Page 12: ...5 Refrigeration Cycle Diagram 12 CS V18DKE CU V18DKE CS V24DKE CU V24DKE ...
Page 13: ...6 Block Diagram 13 CS V18DKE CU V18DKE CS V24DKE CU V24DKE ...
Page 14: ...7 Wiring Diagram CS V18DKE CU V18DKE CS V24DKE CU V24DKE 14 ...
Page 15: ...CS V18DKE CU V18DKE CS V24DKE CU V24DKE 15 ...
Page 71: ...71 CS V18DKE CU V18DKE CS V24DKE CU V24DKE ...
Page 73: ...19 2 Remote Control 73 CS V18DKE CU V18DKE CS V24DKE CU V24DKE ...