12

Please remove the Filter / PM2.5 Filter before wash/rinse the
dust filter with water.

Dust filters

Every 2 weeks

• Wash/rinse the dust filters gently 
  with water to avoid damage to the 
  filter surface.
• Dry the dust filters thoroughly under shade, 
  away from fire or direct sunlight.
• Replace any damaged filters.

Remove air filter

Attach air filter

Filter & PM 2.5 filter

• Clean the filter whenever necessary.
• Don’t wash/rinse the filter with water.
• The surface of the filter shouldn’t be rubbed
  with any object.
• The filter shouldn’t be pulled with strong force
  as it may get damaged.

Filter / PM 2.5 filter.

This filter is applicable to specific models only.

Dust filters

*PM2.5 Filter

*Filter

ACXF55-2301̲OL.ai   12   1/27/2020   7:19:39 PM

ACXF55-2301̲OL.ai   12   1/27/2020   7:19:39 PM

Summary of Contents for CS-TU12VKY Series

Page 1: ...nasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference C POWERFUL SLEEP POWER CS TU12VKYW series CS TU18VKYW series CS RU12VKYW series CS RU18VKYW series CS RU24VKYW series CU TU12VKYW series CU TU18VKYW series CU RU12VKYW series CU RU18VKYW series CU RU24VKYW series C POWERFUL POWE...

Page 2: ...C or higher degrees may save energy Default set temperature is 24 C in COOL mode as per country guidelines Use remote control around 7 m from the remote control receiver of the indoor unit ACXF55 2301 OL ai 2 1 27 2020 7 19 37 PM ACXF55 2301 OL ai 2 1 27 2020 7 19 37 PM ...

Page 3: ...K CHECK Safety precautions 4 9 How to use 10 11 Cleaning instructions 12 Troubleshooting 13 BEE Regulation 14 Information 15 7m ACXF55 2301 OL ai 3 1 27 2020 7 19 37 PM ACXF55 2301 OL ai 3 1 27 2020 7 19 37 PM ...

Page 4: ...iances etc Refer to Table A of Installation instructions table for Amin m Be aware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handin...

Page 5: ...410A R22 models Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side For R32 and R410A the same flare nut o...

Page 6: ...uthorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall be...

Page 7: ... any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks shall ...

Page 8: ...and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazing...

Page 9: ...ied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrige...

Page 10: ...rates at low fan speed to give a gentle cooling operation FAN To operate Air Con in Fan Only mode Indoor unit temp display will show set temp for AUTO COOL DRY mode and room temp for FAN mode Only indoor unit fan operates as per remote settings Outdoor is OFF so no cooling achieved Provides air circulation in the room C POWERFUL SLEEP POWER This operation is to achieve faster cooling This operatio...

Page 11: ...y pressing or then press The nearest timer setting will be displayed and will activate in sequence When ON Timer is set the unit may start earlier up to 15 minutes before the actual set time in order to achieve the desired temperature on time Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Quick guide 11 ACXF55 2301 OL ai...

Page 12: ...place any damaged filters Remove air filter Attach air filter Filter PM 2 5 filter Clean the filter whenever necessary Don t wash rinse the filter with water The surface of the filter shouldn t be rubbed with any object The filter shouldn t be pulled with strong force as it may get damaged Filter PM 2 5 filter This filter is applicable to specific models only Dust filters PM2 5 Filter Filter ACXF5...

Page 13: ...The unit stops and some alpha numeric codes appear on IDU display 13 ACXF55 2301 OL ai 13 1 27 2020 7 19 41 PM ACXF55 2301 OL ai 13 1 27 2020 7 19 41 PM ...

Page 14: ...nit Indoor unit Temperature Display will show for Full Load and for Half Load Setting Testing Guidelines Cooling Test Mode for Full Load 100 and Half Load 50 1 Mode Select COOL 2 Temperature a 16 ºC for Full Load 100 3 Air Swing S 4 Fan speed et vane position to 3rd step from top b 17 ºC for Half Load 50 Auto OFF ON Button Indication for Half load Indication for Full load For Full Load For Half Lo...

Page 15: ...tp www panasonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental breaka...

Page 16: ...ere is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information included in the Operation Instructions and or Installation Instructions ACXF55 2301 OL ai 16 1 27 2020 7 19 42 PM ACXF55 23...