background image

ENGLISH

11

 

CAUTION

INDOOR UNIT AND OUTDOOR UNIT

Do not wash the indoor unit with water, 

benzene, thinner or scouring powder to avoid 

damage or corrosion at the unit.
Do not use for preservation of precise equipment, 

food, animals, plants, artwork or other objects. 

This may cause quality deterioration, etc.

Do not use any combustible equipment in front 

of the airflow outlet to avoid fire propagation.
Do not expose plants or pet directly to airflow to 

avoid injury, etc.

Do not touch the sharp aluminium fin, 

sharp parts may cause injury.

Do not switch ON the indoor unit when waxing 

the floor. After waxing, aerate the room properly 

before operating the unit.
Do not install the unit in oily and smoky areas to 

prevent damage to the unit.
Do not dismantle the unit for cleaning purpose 

to avoid injury.

Do not step onto unstable bench when cleaning 

the unit to avoid injury.
Do not place vase or water container on the 

unit. Water may enter the unit and degrade the 

insulation. This may cause an electric shock.

Do not open window or door for long time during 

COOL mode operation. 
Ensure drainage pipe is connected properly and 

keep drainage outlet clear of gutters, containers 

or does not immersed in water to prevent water 

leakage.
After a long period of use or use with any 

combustible equipment, aerate the room 

regularly.

After a long period of use, make sure the 

installation rack is not deteriorate to prevent the 

unit from falling down.

REMOTE CONTROL

Do not use rechargeable (Ni-Cd) batteries.

It may damage the remote control.

To prevent malfunction or damage of the remote 

control:

•  Remove the batteries if the unit is not going to 

be used for a long period of time. 

•  New batteries of the same type must be 

inserted following the polarity stated. 

POWER SUPPLY

Do not pull the cord to disconnect the plug to 

prevent electric shock.

 

WARNING

POWER SUPPLY

If the supply cord is damage, it must be 

replaced by the manufacturer, its service agent 

or similarly qualified persons in order to avoid 

a hazard.

It is strongly recommended to be installed 

with Earth Leakage Circuit Breaker (ELCB) 

or Residual Current Device (RCD) to prevent 

electric shock or fire.
To prevent overheating, fire or electric shock:

• Insert the power plug properly.

•  Dust on the power plug should be periodically 

wiped with a dry cloth.

Stop using the product if any abnormality/failure 

occurs and disconnect the power plug or turn off 

the power switch and breaker.

(Risk of smoke/fire/electric shock)

Examples of abnormality/failure

•  The ELCB trips frequently. 

•  Burning smell is observed.

•  Abnormal noise or vibration of the unit is 

observed.

•  Water leaks from the indoor unit. 

•  Power cord or plug becomes abnormally hot.

•  Fan speed cannot be controlled.

•  The unit stops running immediately even if it is 

switched on for operation.

•  The fan does not stop even if the operation is 

stopped.

Contact your local dealer immediately for 

maintenance/repair.
Replacement or installation of power plugs shall 

be performed by authorized/qualified personnel 

only. The wires in this mains lead are coloured 

in accordance with the following code:

Terminals

Red

wires

live

neutral

earth

colours (IEC Standard)

blue

green-yellow

brown

Black

Green/Yellow

Wiring colour may vary depending on a country 

wiring code’s standard.

This equipment must be earthed to prevent 

electric shock or fire.

Prevent electric shock by switching off the 

power supply and unplug when:

- Before cleaning or servicing.

- Extended non-use.

- Abnormally strong lightning activity.

F568519_EN_CS4.indd   11

2012-1-18   11:08:02

Summary of Contents for CS-RE9NKA

Page 1: ...uture reference Operating Instructions Air Conditioner Indoor Unit Outdoor Unit CS RE9NKA CU RE9NKA CS RE12NKA CU RE12NKA Pa na son ic Co rpo rat ion We bsit e http p ana son ic n et Print ed in Chin...

Page 2: ...ATION 16 17 PRODUCT SPECIFICATION 18 QUICK GUIDE BACK COVER ENGLISH Thank you for purchasing Panasonic Air Conditioner NOTE The illustrations in this manual are for explanation purposes only and may d...

Page 3: ...temperature range Temperature C Indoor Outdoor DBT WBT DBT WBT COOLING Maximum 32 23 43 26 Minimum 16 11 16 11 HEATING Maximum 30 24 18 Minimum 16 5 6 DBT Dry bulb temperature WBT Wet bulb temperature...

Page 4: ...4...

Page 5: ...5 Ni Cd ELCB RCD IEC...

Page 6: ...6 8 5 5 AIR SWING 6 7 8 9 ANTI BACTERIAL FILTER 1 OFF 2 16 30 HEAT 20 24 COOL 26 28 DRY 1 2 3 AUTO HEAT COOL DRY 4 5 FAN SPEED 1 3 4 5 8 2 6 7 9...

Page 7: ...7 12 5 1 2 2 1 2 3 4 1 2 2 3 7 10 1 2 2 3...

Page 8: ...8 1 2 3 4 5 6 7 8 9 6 10 pH7 40 2 5 7 1 4 6 8 9 3...

Page 9: ...9 4 SELECT SET CANCEL AIR CONDITIONER QUIET POWERFUL A B 1 5 3 2...

Page 10: ...will cause leakage electric shock or fire Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product damage...

Page 11: ...for a long period of time New batteries of the same type must be inserted following the polarity stated POWER SUPPLY Do not pull the cord to disconnect the plug to prevent electric shock WARNING POWE...

Page 12: ...g preheating COOL mode To enjoy cool air Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode DRY mode To dehumidify the environment Unit operates at low f...

Page 13: ...hour for ON Timer This mode of timer can only be set while the air conditioner is in operation DELAY ON AND OFF TIMER For example to start the air conditioner 7 hours later and stop 10 hours later 1...

Page 14: ...hold until 1 beep is heard then release Cooling Press and hold until you hear double beep sound then release Heating Press the button to turn off 8 AIR FILTERS Clean the filters regularly Wash rinse...

Page 15: ...ep in preparation for the operation when the ON timer has been set Cracking sound during operation Changes of temperature cause the expansion contraction of the unit Check the following before calling...

Page 16: ...plug then please consult authorized dealer under the following conditions Abnormal noise during operation Water foreign particles have entered the remote control Water leaks from Indoor unit Circuit b...

Page 17: ...only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Note for the battery symbol bottom two sy...

Page 18: ...ting Capacity kW 3 30 4 25 Noise Level JIS C 9612 70 dB A dB A 42 42 42 42 Conditions 1m Distance Max cooling heating operation 47 48 48 50 Sound power level dB A 58 58 58 58 63 64 64 66 Air Circulati...

Page 19: ...19...

Page 20: ...00 QUICK GUIDE MODE AUTO HEAT DRY COOL Select the desired mode 2 OFF ON Start stop the operation 1 TEMP Select the desired temperature 3 Remote Control Preparation 1 Remove the battery cover 2 AAA R0...