Panasonic CS-RE9JKX Operating Instructions Manual Download Page 3

3

ENGLISH

Information for Users on Collection and Disposal of Old Equipment and Used Batteries

These symbols on the products, packaging, and/or accompanying documents mean that used electrical and 

electronic products and batteries should not be mixed with general household waste.

For proper treatment, recovery and recycling of old products and used batteries, please take them to applicable 

collection points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC.
By disposing of these products and batteries correctly, you will help to save valuable resources and prevent any 

potential negative effects on human health and the environment which could otherwise arise from inappropriate 

waste handling.
For more information about collection and recycling of old products and batteries, please contact your local 

municipality, your waste disposal service or the point of sale where you purchased the items.
Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.

For business users in the European Union

If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further 

information.

[Information on Disposal in other Countries outside the European Union]

These symbols are only valid in the European Union. If you wish to discard these items, please contact your local 

authorities or dealer and ask for the correct method of disposal.

Note for the battery symbol (bottom two symbol examples):

This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement 

set by the Directive for the chemical involved.

Pb

  

REGULATORY INFORMATION

 REGULATORY INFORMATION

Thank you for purchasing 

Panasonic Air Conditioner

OPERATION CONDITION

OPERATION CONDITION

TABLE OF CONTENTS

TABLE OF CONTENTS

NOTE :

NOTE :

The illustrations in this manual are 
for explanation purposes only and 
may differ from the actual unit. It is 
subjected to change without notice 
for future improvement.

SAFETY PRECAUTIONS

2

REGULATORY INFORMATION

3

PRODUCT OVERVIEW & 

OPERATIONS

4~5

CARE & CLEANING

6

TROUBLESHOOTING

7

PRODUCT SPECIFICATION

38

QUICK GUIDE

BACK COVER

   • Do not switch ON the unit when waxing the 

fl

 oor. After waxing, aerate the room properly before operating the unit.

   • Do not install the unit in oily and smoky areas.

Replacement or installation of power plugs shall be performed by authorized/

quali

fi

 ed personnel only. The wires in this mains lead are coloured in accordance 

with the following code:

Terminals

Red

wires

live

neutral

earth

colours (IEC Standard)

blue

green-yellow

brown

Black

Green/Yellow

Wiring colour may vary depending on a country wiring code’s standard.

This appliance is not intended for use by persons (including children) with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been 

given supervision or instruction concerning use of the appliance by a person responsible for their 

safety. Children should be supervised to ensure that they do not play with the appliance.

Use this air conditioner under the following temperature range

Temperature (°C)

Indoor

Outdoor

*DBT

*WBT

*DBT

*WBT

COOLING

Maximum

32

23

43

26

Minimum

16

11

16

11

HEATING

Maximum

30

-

24

18

Minimum

16

-

-5

-6

NOTICE

: •  This model is not suitable for 24 hours non-stopping operation in heating 

mode below -5°C. When the outdoor temperature is below -5°C and you 

use this model out of above conditions, the outdoor unit might be frozen 

up and stop operation for protection control.

* DBT

:  Dry bulb temperature

* WBT

:  Wet bulb temperature

F566761_EN1.indd   章节2:3

F566761_EN1.indd   章节2:3

2008-12-10   8:47:32

2008-12-10   8:47:32

Summary of Contents for CS-RE9JKX

Page 1: ...ese operating instructions thoroughly and keep them for future reference FRAN AIS 26 31 Avant d utiliser l appareil lisez ce mode d emploi dans son int gralit et conservez le pour toute r f rence ult...

Page 2: ...n work Do not insert your fingers or other objects into the unit rotating parts may cause injury Do not attempt to repair the unit by yourself Power Supply Do not pull the cord to disconnect the plug...

Page 3: ...TION REGULATORY INFORMATION Thank you for purchasing Panasonic Air Conditioner OPERATION CONDITION OPERATION CONDITION TABLE OF CONTENTS TABLE OF CONTENTS NOTE NOTE The illustrations in this manual ar...

Page 4: ...the unit from starting stopping improperly TO SET TEMPERATURE Selection range 16 C 30 C Operating the unit within the recommended temperature could induce energy saving HEAT mode 20 C 24 C COOL mode 2...

Page 5: ...button to select the delay hour The ON TIMER can only be set while the air conditioner is not in operation DELAYOFFAND ON TIMER For example to stop the air conditioner 3 hours later and start 4 hours...

Page 6: ...on it is normal to have the following temperature difference between air inlet and air outlet vents Cooling 8 C Heating 14 C NON SERVICEABLE CRITERIAS NON SERVICEABLE CRITERIAS TURN OFF POWER SUPPLY A...

Page 7: ...resumed after a power failure It is the Auto Restart function of the unit Operation will be restarted automatically under the previous operation mode and airflow direction when power is resumed as the...

Page 8: ...50Hz Single 230V 50Hz Single 230V 50Hz Power Current kW 0 700 0 820 1 010 1 120 1 260 1 540 A 3 45 3 70 4 70 5 20 6 05 7 10 Refrigerant kg R410A 0 810 R410A 0 970 R410A 0 970 Cooling Capacity kW 2 50...

Page 9: ......

Page 10: ...OWERFUL QUIET AUTOQUIET AUTOQUIET OFF Remote Control Preparation Remote Control Preparation Preparaci n del mando a distancia Preparaci n del mando a distancia Preparazione telecomando Preparazione te...

Reviews: