15.5.20. F95 (Cooling High Pressure Abnormality)
Malfunction Decision Conditions
During operation of cooling, when outdoor unit heat exchanger high temperature data (61
°
C) is detected by the outdoor pipe
temperature sensor.
Malfunction Caused
• Outdoor pipe temperature rise due to short circuit of hot discharge air flow.
• Outdoor pipe temperature rise due to defective of outdoor fan motor.
• Outdoor pipe temperature rise due to defective outdoor pipe temperature sensor.
• Outdoor pipe temperature rise due to defective outdoor unit PCB.
Troubleshooting
Summary of Contents for CS-RE18JKX-1
Page 9: ...9 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 10: ...10 5 Dimensions 5 1 Indoor Unit Remote Control ...
Page 11: ...11 5 2 Outdoor Unit 5 2 1 CU RE18JKX 1 ...
Page 12: ...12 5 2 2 CU RE24JKX 1 ...
Page 13: ...13 6 Refrigeration Cycle Diagram ...
Page 14: ...14 7 Block Diagram ...
Page 15: ...15 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 16: ...16 8 2 Outdoor Unit 8 2 1 CU RE18JKX 1 ...
Page 17: ...17 8 2 2 CU RE24JKX 1 ...
Page 18: ...18 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 19: ...19 9 2 Outdoor Unit 9 2 1 CU RE18JKX 1 ...
Page 20: ...20 9 2 2 CU RE24JKX 1 ...
Page 21: ...21 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 22: ...22 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Printed Circuit Board ...
Page 23: ...23 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board 10 2 1 1 CU RE18JKX 1 ...
Page 24: ...24 10 2 2 Main Printed Circuit Board 10 2 2 1 CU RE24JKX 1 ...
Page 25: ...25 10 2 3 Power Printed Circuit Board 10 2 3 1 CU RE24JKX 1 ...
Page 73: ...73 16 1 3 To remove power electronic controller ...
Page 74: ...74 16 1 4 To remove discharge grille 16 1 5 To remove control board ...
Page 75: ...75 16 1 6 To remove cross flow fan and indoor fan motor ...
Page 76: ...76 ...
Page 87: ...87 18 Exploded View and Replacement Parts List 18 1 Indoor Unit ...