Prevent water leakage by ensuring drainage 
pipe is:

 

- Connected properly,

 

- Kept clear of gutters and containers, or

 

- Not immersed in water

After a long period of use or use with any 
combustible equipment, aerate the room 
regularly.

After a long period of use, make sure the 
installation rack does not deteriorate to 
prevent the unit from falling down.

Remote control

Do not use rechargeable (Ni-Cd) batteries. It 
may damage the remote control.

To prevent malfunction or damage of the 
remote control:
• Remove the batteries if the unit is not going 

to be used for a long period of time.

• New batteries of the same type must be 

inserted following the polarity stated.

Power supply

Do not disconnect the plug by pulling the cord 
to prevent electric shock.

Precaution for using R32 refrigerant

The basic installation work procedures are the same as 
conventional refrigerant (R410A, R22) models.

1. Installation (Space)

• Must ensure the installation of pipe-work 

shall be kept to a minimum. Avoid use 
dented pipe and do not allow acute bending.

• Must ensure that pipe-work shall be 

protected from physical damage.

• Must comply with national gas regulations, 

state municipal rules and legislation. Notify 
relevant authorities in accordance with all 
applicable regulations.

• Must ensure mechanical connections be 

accessible for maintenance purposes.

• In cases that require mechanical ventilation, 

ventilation openings shall be kept clear of 
obstruction.

• When disposal of the product, do follow 

to the precautions in #12 and comply with 
national regulations.
Always contact to local municipal offi ces for 
proper handling.

Safety precautions

2. Servicing
2-1. Service personnel

• Any qualifi ed person who is involved with 

working on or breaking into a refrigerant 
circuit should hold a current valid certifi cate 
from an industry-accredited assessment 
authority, which authorizes their competence 
to handle refrigerants safely in accordance 
with an industry recognised assessment 
specifi cation.

• Servicing shall only be performed 

as recommended by the equipment 
manufacturer.
Maintenance and repair requiring the 
assistance of other skilled personnel shall 
be carried out under the supervision of the 
person competent in the use of fl ammable 
refrigerants.

• Servicing shall be performed only as 

recommended by the manufacturer.

2-2. Work

• Prior to beginning work on systems 

containing fl ammable refrigerants, safety 
checks are necessary to ensure that the risk 
of ignition is minimised.
For repair to the refrigerating system, the 
precautions in #2-2 to #2-8 must be followed 
before conducting work on the system.

• Work shall be undertaken under a controlled 

procedure so as to minimize the risk of a 
fl ammable gas or vapour being present while 
the work is being performed.

• All maintenance staff and others working 

in the local area shall be instructed and 
supervised on the nature of work being 
carried out.

• Avoid working in confi ned spaces.
• Wear appropriate protective equipment, 

including respiratory protection, as 
conditions warrant.

• Ensure that the conditions within the area 

have been made safe by limit of use of any 
fl ammable material. Keep all sources of 
ignition and hot metal surfaces away.

2-3. Checking for presence of refrigerant

• The area shall be checked with an 

appropriate refrigerant detector prior to and 
during work, to ensure the technician is 
aware of potentially fl ammable atmospheres.

• Ensure that the leak detection equipment 

being used is suitable for use with fl ammable 
refrigerants, i.e. non sparking, adequately 
sealed or intrinsically safe.

• In case of leakage/spillage happened, 

immediately ventilate area and stay upwind 
and away from spill/release.

• In case of leakage/spillage happened, do 

notify persons down wind of the leaking/spill, 
isolate immediate hazard area and keep 
unauthorized personnel out.

ACXF55-1915_OL.ai   6   6/1/2018   1:19:57 PM

ACXF55-1915_OL.ai   6   6/1/2018   1:19:57 PM

Summary of Contents for CS-QN12UKY Series

Page 1: ...tioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference C POWERFUL POWERFUL SLEEP SLEEP POWER POWER ACXF55 1915_OL ai 1 6 1 2018 1 19 49 PM ACXF55 1915_OL ai 1 6 1 2018 1 19 49 PM ...

Page 2: ...ess SET or CLOCK again Operating the unit at 25 C or higher degrees may save energy Better comfort condition at 25 C or higher degrees ACXF55 1915_OL ai 2 6 1 2018 1 19 56 PM ACXF55 1915_OL ai 2 6 1 2018 1 19 56 PM ...

Page 3: ...FAN Safety precautions 4 9 How to use 10 11 Cleaning instructions 12 Troubleshooting 13 Information 14 ACXF55 1915_OL ai 3 6 1 2018 1 19 57 PM ACXF55 1915_OL ai 3 6 1 2018 1 19 57 PM ...

Page 4: ...liances etc Refer to Table A of Installation instructions table for Amin m Be aware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handi...

Page 5: ...R410A R22 models Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side For R32 and R410A the same flare nut ...

Page 6: ...authorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall b...

Page 7: ...o any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks shall...

Page 8: ... and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazin...

Page 9: ...tied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrig...

Page 10: ...IDU fan running as per remote setting fan speed and air flow direction Indoor unit temperature display will show standard set temperature of 30 ºC and no set temperature is displayed on remote controller display SLEEP Room temperature 23 C above Below 23 C 25 C 22 C Standard setting temperature ACXF55 1915_OL ai 10 6 1 2018 1 19 58 PM ACXF55 1915_OL ai 10 6 1 2018 1 19 58 PM ...

Page 11: ...u can restore the timer again by pressing or then press The nearest timer setting will be displayed and will activate in sequence When ON Timer is set the unit may start earlier up to 15 minutes before the actual set time in order to achieve the desired temperature on time Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Q...

Page 12: ...Please remove the PM2 5 Filter before wash rinse the filter with water 12 ACXF55 1915_OL ai 12 6 1 2018 1 19 58 PM ACXF55 1915_OL ai 12 6 1 2018 1 19 58 PM ...

Page 13: ...The unit stops and some alpha numeric codes appear on IDU display 13 ACXF55 1915_OL ai 13 6 1 2018 1 20 00 PM ACXF55 1915_OL ai 13 6 1 2018 1 20 00 PM ...

Page 14: ...nic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental breakage Provide in...

Page 15: ...English Information Memo 15 ACXF55 1915_OL ai 15 6 1 2018 1 20 00 PM ACXF55 1915_OL ai 15 6 1 2018 1 20 00 PM ...

Page 16: ...here is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information included in the Operation Instructions and or Installation Instructions ACXF55 1915_OL ai 16 6 1 2018 1 20 00 PM ACXF55 19...

Reviews: