Panasonic CS-PV12CKE Operating Instructions Manual Download Page 8

7

1

2

3

4

TIMER OPERATION

To start and stop the air conditioner operation
automatically.

Delay OFF Timer

• For example, to stop the air conditioner after 5 hours.
• To select Delay OFF timer, press the 

1

 button once.

• Press 

3

 button to select delay hour.

Delay ON Timer

• For example, to start the air conditioner after 2 hours.
• To select Delay ON timer, press the 

1

 button twice.

• Press 

3

 button to select delay hour.

Delay OFF and ON Timer

• For example, to stop the air conditioner after 3 hours

and restart after 4 hours.

• To select Delay OFF & ON timer, press the 

1

 button

3 times.

• Press 

3

 button to select delay OFF timer & press 

4

button to select delay ON timer.

Delay ON and OFF Timer

• For example, to start the air conditioner after

10 hours and restart after 7 hours.

• To select Delay ON & OFF timer, press the 

1

 button

4 times.

• Press 

3

 button to select delay ON timer & press 

4

button to select delay OFF timer.

Heat Pump Model

COOL,DRY, – 15 minutes

in advance

HEAT, AUTO – 30 minutes

in advance

Cooling Model

COOL,DRY, – 15 minutes
AUTO

in advance

CARE AND MAINTENANCE

Cleaning the Indoor Unit and Remote
Control

• Wipe gently with a soft, dry cloth.
• Do not use water hotter than 40˚C or polishing fluid

to clean the unit.

Cleaning the Air Filter

(Recommendation:- If the unit is operated in a dusty
environment, clean the filters every two weeks,
continuous use of this dirty filters will reduce cooling
or heating efficiency.)

1

Remove dirt using a vacuum cleaner.

2

Wash back of the air filter with water.

3

If badly soiled, wash it with soap or a mild household
detergent.

4

Let it dry and reinstall it.
Be sure the “FRONT” mark is facing you.

*

Damaged air filter.
Consult the nearest authorized dealer.
Part No.: CWD001047.

• Do not use benzene, thinner, scouring powder or

clothes soaked in caustic chemical to clean the unit.

Cleaning the Front Panel

(Must be removed before washing)

1

Raise the front panel higher than the horizontal and
pull to remove it.

2

Gently wash with water and a sponge.
• Do not press the front panel too hard when washing.
• When use kitchen cleaning fluid (neutral detergent),

rinse throughly.

• Do not dry the front panel under direct sunlight.

3

To fix the front panel, raise the front panel
horizontally, match the protruding portion on the
indoor unit to the fulcrum and push into place.

To Confirm Setting

• Press the 

2

button once to activate the ON/OFF

Delay hour operation, which will be activated after
reaching the number of hours (1-12) that were set.

To Cancel Setting

• Press the 

2

 button to cancel the setting.

• Alternatively, pressing the OFF/ON button will also

cancel the setting.

• Also, by pressing the 

2

 button, the previous

setting will again be activated.

• Once the Delay ON/OFF Timer is set, operation will

start at the set time everyday.

• The current time is not displayed when the timers

are set.

• When both timers are used together, the TIMER

mode indicator on the indoor unit remains lit even
when the operation is stopped by the OFF-TIMER.

Fulcrum

Protruding portion
on indoor unit

F564222 01-09-EN

9/12/03, 5:28 PM

7

Summary of Contents for CS-PV12CKE

Page 1: ...E CU PW9CKE CS PW12CKE CU PW12CKE ENGLISH P 1 P 9 PORTUGUÊS P 10 P 18 DEUTSCH P 19 P 27 FRANÇAIS P 28 P 36 NEDERLAND P 37 P 45 ITALIANO P 46 P 54 GREEK P 55 P 63 ESPAÑOL P 64 P 72 RUSSIAN P 73 P 82 BULGARIAN P 83 P 91 Before using your air conditioner please read this operating instructions carefully and keep it for future reference F564222 MATSUSHITA INDUSTRIAL CORP LOT 2 PERSIARAN TENGKU AMPUAN ...

Page 2: ...before servicing this appliance 3 Do not repair by yourself In case of malfunction of this appliance do not repair by yourself Contact the sales dealer or service dealer for a repair 4 Turn off the power Isolation from main power supply Pull off the power plug from the receptacle or switch off the breaker or switch off the power disconnecting mean to isolate the equipment from the main power suppl...

Page 3: ...lf Improper installation will cause leakage electric shock or fire Please engage an authorized dealer or specialist for the installation work Caution Operation Precautions Warning This sign warns of death or serious injury Do not share outlet Do not insert plug to operate the unit Do not pull out plug to stop the unit Do not operate with wet hands Do not damage or modify the power cord Do not inse...

Page 4: ...tor GREEN r Mode Indicator ORANGE Indoor Unit when the front panel is opened 1 Front Panel 2 Air Filters Outdoor Unit 1 Air Intake Vents 2 Ground Terminal Inside cover 3 Piping 4 Connecting Cable 5 Drain Hose 6 Air Outlet Vents Accessories Remote Control Remote Control Indication Sticker Remote Control Holder Two RO3 AAA dry cell batteries or equivalent 2 3 4 5 7 6 1 2 1 1 6 2 3 4 5 2 3 9 12 03 5 ...

Page 5: ...in type of fluorescent lamps may affect signal reception Consult your dealer 1 2 4 3 5 8 7 9 6 How to Insert the Batteries 1 Slide down the remote control cover completely 2 Insert the batteries Be sure the direction is correct About the batteries Can be used for approximately one year Observe the following when replacing the batteries Replace with new batteries of the same type Do not use recharg...

Page 6: ...s 2 to select Cooling Model AUTO Automatic Operation COOL Cooling Operation DRY Soft Dry Operation FAN Air Circulation Operation Heat Pump Model AUTO Automatic Operation HEAT Heating Operation COOL Cooling Operation DRY Soft Dry Operation Operation Cooling Soft Dry Heating Standard temperature 25 C 22 C 21 C Indoor temperature 23 C 20 C Heat Pump Model COOL 26 C 28 C DRY 1 C 2 C lower than the roo...

Page 7: ...m temperature drops to 2 C below the set temperature It is useful when using a heater ng the Vertical Airflow Direction ess 5 or 6 to select Cooling Model Setting the Horizontal Airflow Direction Use this air conditioner under the following conditions Cooling Model Adjust it manually Notes If the unit is not going to be used for an extended period of time turn off the main power supply If it is le...

Page 8: ...2 Wash back of the air filter with water 3 If badly soiled wash it with soap or a mild household detergent 4 Let it dry and reinstall it Be sure the FRONT mark is facing you Damaged air filter Consult the nearest authorized dealer Part No CWD001047 Do not use benzene thinner scouring powder or clothes soaked in caustic chemical to clean the unit Cleaning the Front Panel Must be removed before wash...

Page 9: ...er indicator on the indoor unit will blink until the operation mode is selected automatically To cancel this operation press once more Remote Control Signal Receiving Sound To switch off the beep Signal Receiving Sound press the Auto Operation button for 10 seconds continuously or longer Beep beep sound will be heard at the tenth seconds Note Beep sound will be heard at the fifth seconds However p...

Page 10: ...re in the air condenses into water on the cool surface of outdoor unit piping that causes dripping This is to melt the frost which has accumulated on the outdoor unit defrosting operating This will take no longer than about 12 minutes Water drips from the outdoor unit Wait until this operation ends the power indicator will light up Frost will accumulates on the outdoor unit when the outdoor temper...